Diseño, simulación y fabricación de un dispositivo de fijación craneal bioabsorbible, mediante tecnologías de impresión 3D

RiuNet: Repositorio Institucional de la Universidad Politécnica de Valencia

Compartir/Enviar a

Citas

Estadísticas

  • Estadisticas de Uso

Diseño, simulación y fabricación de un dispositivo de fijación craneal bioabsorbible, mediante tecnologías de impresión 3D

Mostrar el registro sencillo del ítem

Ficheros en el ítem

dc.contributor.advisor Boronat Vitoria, Teodomiro es_ES
dc.contributor.advisor García García, Daniel es_ES
dc.contributor.author Ivorra Martínez, Juan es_ES
dc.date.accessioned 2020-07-15T11:13:21Z
dc.date.available 2020-07-15T11:13:21Z
dc.date.created 2020-06-22
dc.date.issued 2020-07-15 es_ES
dc.identifier.uri http://hdl.handle.net/10251/148051
dc.description.abstract [ES] En el presente trabajo se han estudiado las características de un polímero bioabsorbible, poli(3-hidroxibutirato-co-3-hidroxihexanoato) - PHBH, con cargas biocompatibles y osteoconductoras de hidroxiapatita - HA, para el diseño, simulación y fabricación de una placa de fijación craneal bioabsorbible. Para ello se han llevado a cabo diferentes ensayos de caracterización mecánica (tracción, flexión, impacto y dureza), ensayos térmicos (calorimetría diferencial de barrido, análisis termogravimétrico), ensayos termo-mecánicos, así como ensayos térmico mecánicos-dinámicos. La combinación de PHBH con cargas de HA presenta un alto interés para su empleo como material en el campo de la biomedicina. La biocompatibilidad de ambos componentes, así como la capacidad osteoconductora de la HA ofrecen un alto interés en el área de reconstrucción y/o fijación de fracturas óseas. La capacidad de degradación de ambos componentes permite que el dispositivo de fijación se reabsorba dentro del cuerpo humano evitando una segunda intervención quirúrgica para su eliminación. Considerando las características particulares del sistema PHBH/HA, este trabajo de investigación propone el diseño, cálculo y fabricación de un dispositivo de fijación craneal bioabsorbible. Para ello se ha empleado SolidWorks como plataforma CAD para el diseño de la geometría de la placa de fijación. Además, se ha planteado la optimización de la geometría mediante herramientas CAE (Computer Aided Engineering), a través del método de los elementos finitos con el empleo del software NX Nastran. es_ES
dc.description.abstract [EN] In the present work, the characteristics of a bioabsorbable polymer, poly(3-hydroxybutyrate-co-3-hydroxyhexanoate) - PHBH, with biocompatible and osteoconductive hydroxyapatite charges - HA, have been studied for the design, simulation and manufacture of a bioabsorbable cranial fixation plate. For this purpose, different mechanical characterization tests (tensile, flexion, impact and hardness), thermal tests (differential scanning calorimetry, thermogravimetric analysis), thermo-mechanical tests, as well as mechanical-dynamic thermal tests have been carried out. The combination of PHBH with HA fillers is of great interest for its use as a material in the field of biomedicine. The biocompatibility of both components as well as the osteoconductive capacity of HA is of great interest in the area of reconstruction and/or fixation of bone fractures. The degradation capacity of both components allows the fixation device to be reabsorbed into the human body avoiding a second surgical intervention for its elimination. Considering the particular characteristics of the PHBH/HA system, this research work proposes the design, calculation and manufacture of a bio-absorbable cranial fixation device. For this purpose, SolidWorks has been used as a CAD platform for the design of the geometry of the fixation plate. In addition, the optimization of the geometry has been considered using CAE (Computer Aided Engineering) tools, through the finite element method with the use of NX Nastran software. es_ES
dc.format.extent 123 es_ES
dc.language Español es_ES
dc.publisher Universitat Politècnica de València es_ES
dc.rights Reserva de todos los derechos es_ES
dc.subject Hidroxiapatita es_ES
dc.subject Placa craneal es_ES
dc.subject Polímero bioabsorbible es_ES
dc.subject Simulación es_ES
dc.subject Impresión 3D es_ES
dc.subject Elementos finitos es_ES
dc.subject PHBH es_ES
dc.subject Hydroxyapatite es_ES
dc.subject Cranial plate es_ES
dc.subject Bioabsorbable polymer es_ES
dc.subject Simulation es_ES
dc.subject 3D printing es_ES
dc.subject Finite elements es_ES
dc.subject.classification INGENIERIA DE LOS PROCESOS DE FABRICACION es_ES
dc.subject.classification CIENCIA DE LOS MATERIALES E INGENIERIA METALURGICA es_ES
dc.subject.other Máster Universitario en Ingeniería, Procesado y Caracterización de Materiales-Màster Universitari en Enginyeria, Processament i Caracterització de Materials es_ES
dc.title Diseño, simulación y fabricación de un dispositivo de fijación craneal bioabsorbible, mediante tecnologías de impresión 3D es_ES
dc.type Tesis de máster es_ES
dc.rights.accessRights Cerrado es_ES
dc.contributor.affiliation Universitat Politècnica de València. Escuela Politécnica Superior de Alcoy - Escola Politècnica Superior d'Alcoi es_ES
dc.contributor.affiliation Universitat Politècnica de València. Departamento de Ingeniería Mecánica y de Materiales - Departament d'Enginyeria Mecànica i de Materials es_ES
dc.contributor.affiliation Universitat Politècnica de València. Instituto de Tecnología de Materiales - Institut de Tecnologia de Materials es_ES
dc.description.bibliographicCitation Ivorra Martínez, J. (2020). Diseño, simulación y fabricación de un dispositivo de fijación craneal bioabsorbible, mediante tecnologías de impresión 3D. http://hdl.handle.net/10251/148051 es_ES
dc.description.accrualMethod TFGM es_ES
dc.relation.pasarela TFGM\124003 es_ES


Este ítem aparece en la(s) siguiente(s) colección(ones)

Mostrar el registro sencillo del ítem