Evaluation of modern camera calibration techniques for conventional diagnostic X-ray imaging settings

RiuNet: Institutional repository of the Polithecnic University of Valencia

Share/Send to

Cited by

Statistics

Evaluation of modern camera calibration techniques for conventional diagnostic X-ray imaging settings

Show full item record

Albiol Colomer, F.; Corbi, A.; Albiol Colomer, A. (2017). Evaluation of modern camera calibration techniques for conventional diagnostic X-ray imaging settings. Radiological Physics and Technology. 10(1):68-81. https://doi.org/10.1007/s12194-016-0369-y

Por favor, use este identificador para citar o enlazar este ítem: http://hdl.handle.net/10251/151163

Files in this item

Item Metadata

Title: Evaluation of modern camera calibration techniques for conventional diagnostic X-ray imaging settings
Author: Albiol Colomer, Francisco Corbi, Alberto Albiol Colomer, Alberto
UPV Unit: Universitat Politècnica de València. Departamento de Comunicaciones - Departament de Comunicacions
Issued date:
Abstract:
[EN] We explore three different alternatives for obtaining intrinsic and extrinsic parameters in conventional diagnostic X-ray frameworks: the direct linear transform (DLT), the Zhang method, and the Tsai approach. We ...[+]
Subjects: Conventional X-ray camera calibration , Detector resolution , Intrinsic and extrinsic parameters , Zhang's method , Direct linear transform , Tsai's approach
Copyrigths: Reserva de todos los derechos
Source:
Radiological Physics and Technology. (issn: 1865-0333 )
DOI: 10.1007/s12194-016-0369-y
Publisher:
Springer-Verlag
Publisher version: https://doi.org/10.1007/s12194-016-0369-y
Project ID:
MINECO/SEV-2014-0398
UV/CPI-15170
MINECO/CSD2007-00042
MINECO/CPAN13TR01
MINETUR/TSI-100101-2013-019
Thanks:
This work was carried out with the support of Information Storage S. L., University of Valencia (Grant #CPI-15170), CSD2007-00042 Consolider Ingenio CPAN (Grant #CPAN13TR01), Spanish Ministry of Industry, Energy and Tourism ...[+]
Type: Artículo

References

Selby BP, Sakas G, Groch W-D, Stilla U. Patient positioning with X-ray detector self-calibration for image guided therapy. Aust Phys Eng Sci Med. 2011;34:391–400.

Markelj P, Likar B. Registration of 3D and 2D medical images. PhD Thesis, University of Ljubljana; 2010.

Miller T, Quintana E. Stereo X-ray system calibration for three-dimensional measurements. Springer, 2014. pp. 201–207. [+]
Selby BP, Sakas G, Groch W-D, Stilla U. Patient positioning with X-ray detector self-calibration for image guided therapy. Aust Phys Eng Sci Med. 2011;34:391–400.

Markelj P, Likar B. Registration of 3D and 2D medical images. PhD Thesis, University of Ljubljana; 2010.

Miller T, Quintana E. Stereo X-ray system calibration for three-dimensional measurements. Springer, 2014. pp. 201–207.

Rougé A, Picard C, Ponchut C, Trousset Y. Geometrical calibration of X-ray imaging chains for three-dimensional reconstruction. Comput Med Imaging Graph. 1993; 295–300.

Trucco E, Verri A. Introductory techniques for 3-D computer vision. Prentice Hall Englewood Cliffs, 1998.

Moura DC, Barbosa JG, Reis AM, Tavares JMRS. A flexible approach for the calibration of biplanar radiography of the spine on conventional radiological systems. Comput Model Eng Sci. 2010; 115–137.

Schumann S, Thelen B, Ballestra S, Nolte L-P, Buchler P, Zheng G. X-ray image calibration and its application to clinical orthopedics. Med Eng Phys. 2014;36:968–74.

Selby B, Sakas G, Walter S, Stilla U. Geometry calibration for X-ray equipment in radiation treatment devices. 2007. pp. 968–974.

de Moura DC, Barbosa JMG, da Silva Tavares JMR, Reis A. Calibration of bi-planar radiography with minimal phantoms. In: Symposium on Informatics Engineering. 2008. pp. 1–10.

Medioni G, Kang SB. Emerging topics in computer vision. Prentice Hall. 2004.

Bushong S. Radiologic science for technologists: physics, biology, and protection. Elsevier. 2012.

Rowlands JA. The physics of computed radiography. Phys Med Biol. 2002;47:123–66.

Dobbins JT, Ergun DL, Rutz L, Hinshaw DA, Blume H, Clark DC. DQE(f) of four generations of computed radiography acquisition devices. Med Phys. 1995;22:1581–93.

Hartley R. Self-calibration from multiple views with a rotating camera. In: European Conference on Computer Vision. 1994. pp. 471–478.

Tsai R. A versatile camera calibration technique for high accuracy 3D machine vision metrology using off-the-shelf TV cameras and lenses. IEEE J Robot Autom. 1985;3(4):323–44.

Hartley R, Zisserman A. Multiple view geometry in computer vision. Cambridge University Press. 2004.

Zhang Z. A flexible new technique for camera calibration. IEEE Trans Pattern Anal Mach Intell. 2000;22:1330–4.

Remondino F, Fraser C. Digital camera calibration methods: considerations and comparisons. Symposium Image Eng Vis Metrol. 2006;36:266–72.

Zollner H, Sablatnig R. Comparison of methods for geometric camera calibration using planar calibration targets. In: Digital Imaging in Media and Education. 2004. pp. 237–244.

[-]

This item appears in the following Collection(s)