- -

Entropy at the right atrium as a predictor of atrial fibrillation recurrence outcome after pulmonary vein ablation

RiuNet: Institutional repository of the Polithecnic University of Valencia

Share/Send to

Cited by

Statistics

  • Estadisticas de Uso

Entropy at the right atrium as a predictor of atrial fibrillation recurrence outcome after pulmonary vein ablation

Show full item record

Cervigon, R.; Moreno, J.; Garcia-Quintanilla, J.; Perez-Villacastin, J.; Castells, F. (2016). Entropy at the right atrium as a predictor of atrial fibrillation recurrence outcome after pulmonary vein ablation. BIOMEDIZINISCHE TECHNIK. 61(1):29-36. https://doi.org/10.1515/bmt-2014-0172

Por favor, use este identificador para citar o enlazar este ítem: http://hdl.handle.net/10251/151437

Files in this item

Item Metadata

Title: Entropy at the right atrium as a predictor of atrial fibrillation recurrence outcome after pulmonary vein ablation
Author: Cervigon, Raquel Moreno, Javier Garcia-Quintanilla, Jorge Perez-Villacastin, Julian Castells, Francisco
UPV Unit: Universitat Politècnica de València. Departamento de Ingeniería Electrónica - Departament d'Enginyeria Electrònica
Issued date:
Abstract:
[EN] Atrial fibrillation (AF) recurrence rates after successful ablation procedures are still high and difficult to predict. This work studies the capability of entropy measured from intracardiac recordings as an indicator ...[+]
Subjects: Ablation , Atrial fibrillation , Sample entropy
Copyrigths: Cerrado
Source:
BIOMEDIZINISCHE TECHNIK. (issn: 0939-4990 )
DOI: 10.1515/bmt-2014-0172
Publisher:
Walter de Gruyter GmbH
Publisher version: https://doi.org/10.1515/bmt-2014-0172
Project ID:
info:eu-repo/grantAgreement/Junta de Castilla y León//PPII-2014-024-P/ES/ANALISIS DE REGISTROS INTRACADIACOS PARA PREDECIR EL EXITO DE LA ABLACION EN PACIENTES CON FIBRILACION AURICULAR/
Thanks:
This work was supported by the Castilla-La Mancha Research Scheme (PPII- 2014-024-P).
Type: Artículo

References

Nilsson, F., Stridh, M., Bollmann, A., & Sörnmo, L. (2006). Predicting spontaneous termination of atrial fibrillation using the surface ECG. Medical Engineering & Physics, 28(8), 802-808. doi:10.1016/j.medengphy.2005.11.010

Petersson, R., Sandberg, F., Platonov, P. G., & Holmqvist, F. (2011). Noninvasive estimation of organization in atrial fibrillation as a predictor of sinus rhythm maintenance. Journal of Electrocardiology, 44(2), 171-175. doi:10.1016/j.jelectrocard.2010.10.033

Pincus, S. (1995). Approximate entropy (ApEn) as a complexity measure. Chaos: An Interdisciplinary Journal of Nonlinear Science, 5(1), 110-117. doi:10.1063/1.166092 [+]
Nilsson, F., Stridh, M., Bollmann, A., & Sörnmo, L. (2006). Predicting spontaneous termination of atrial fibrillation using the surface ECG. Medical Engineering & Physics, 28(8), 802-808. doi:10.1016/j.medengphy.2005.11.010

Petersson, R., Sandberg, F., Platonov, P. G., & Holmqvist, F. (2011). Noninvasive estimation of organization in atrial fibrillation as a predictor of sinus rhythm maintenance. Journal of Electrocardiology, 44(2), 171-175. doi:10.1016/j.jelectrocard.2010.10.033

Pincus, S. (1995). Approximate entropy (ApEn) as a complexity measure. Chaos: An Interdisciplinary Journal of Nonlinear Science, 5(1), 110-117. doi:10.1063/1.166092

Aliot, E., Breithardt, G., Brugada, J., Camm, J., Lip, G. Y. H., … Vardas, P. E. (2010). An international survey of physician and patient understanding, perception, and attitudes to atrial fibrillation and its contribution to cardiovascular disease morbidity and mortality. Europace, 12(5), 626-633. doi:10.1093/europace/euq109

Schotten, U., Maesen, B., & Zeemering, S. (2012). The need for standardization of time- and frequency-domain analysis of body surface electrocardiograms for assessment of the atrial fibrillation substrate. Europace, 14(8), 1072-1075. doi:10.1093/europace/eus056

Lo, L.-W., Tai, C.-T., Lin, Y.-J., Chang, S.-L., Udyavar, A. R., Hu, Y.-F., … Chen, S.-A. (2009). Predicting factors for atrial fibrillation acute termination during catheter ablation procedures: Implications for catheter ablation strategy and long-term outcome. Heart Rhythm, 6(3), 311-318. doi:10.1016/j.hrthm.2008.11.013

Cervigón, R., Moreno, J., Reilly, R. B., Millet, J., Pérez-Villacastín, J., & Castells, F. (2010). Entropy measurements in paroxysmal and persistent atrial fibrillation. Physiological Measurement, 31(7), 1011-1020. doi:10.1088/0967-3334/31/7/010

Botteron, G. W., & Smith, J. M. (1995). A technique for measurement of the extent of spatial organization of atrial activation during atrial fibrillation in the intact human heart. IEEE Transactions on Biomedical Engineering, 42(6), 579-586. doi:10.1109/10.387197

[-]

recommendations

 

This item appears in the following Collection(s)

Show full item record