Ergonomics assessment of passive upper-limb exoskeletons in an automotive assembly plant

RiuNet: Repositorio Institucional de la Universidad Politécnica de Valencia

Compartir/Enviar a

Citas

Estadísticas

  • Estadisticas de Uso

Ergonomics assessment of passive upper-limb exoskeletons in an automotive assembly plant

Mostrar el registro completo del ítem

Iranzo-Egea, S.; Piedrabuena Cuesta, A.; Iordanov, D.; Martinez, U.; Belda Lois, JM. (2020). Ergonomics assessment of passive upper-limb exoskeletons in an automotive assembly plant. Applied Ergonomics. 87:1-6. https://doi.org/10.1016/j.apergo.2020.103120

Por favor, use este identificador para citar o enlazar este ítem: http://hdl.handle.net/10251/153114

Ficheros en el ítem

Metadatos del ítem

Título: Ergonomics assessment of passive upper-limb exoskeletons in an automotive assembly plant
Autor: Iranzo-Egea, Sofía Piedrabuena Cuesta, Alicia IORDANOV, D. MARTINEZ, U. BELDA LOIS, JUAN MANUEL
Entidad UPV: Universitat Politècnica de València. Departamento de Ingeniería Mecánica y de Materiales - Departament d'Enginyeria Mecànica i de Materials
Fecha difusión:
Resumen:
[EN] Over the years, the industry's interest in using external support devices, such as exoskeletons, is increasing. They are introduced as a new technique for improving the conditions of workers and for reducing the risk ...[+]
Palabras clave: Exoskeleton , Upper-limb , EMG , Motion-tracking , Industry conditions , Automotive
Derechos de uso: Cerrado
Fuente:
Applied Ergonomics. (issn: 0003-6870 )
DOI: 10.1016/j.apergo.2020.103120
Editorial:
Elsevier
Versión del editor: https://doi.org/10.1016/j.apergo.2020.103120
Agradecimientos:
This study was supported by a contract with MSX International Techservices, S.L., and the work was done with the collaboration of Ford Valencia Body & Assembly personnel. However, these individuals had no involvement either ...[+]
Tipo: Artículo

recommendations

 

Este ítem aparece en la(s) siguiente(s) colección(ones)

Mostrar el registro completo del ítem