- -

Proposal of a new diffractive corneal inlay to improve near vision in a presbyopic eye

RiuNet: Repositorio Institucional de la Universidad Politécnica de Valencia

Compartir/Enviar a

Citas

Estadísticas

  • Estadisticas de Uso

Proposal of a new diffractive corneal inlay to improve near vision in a presbyopic eye

Mostrar el registro sencillo del ítem

Ficheros en el ítem

dc.contributor.author Montagud-Martínez, Diego es_ES
dc.contributor.author Ferrando, Vicente es_ES
dc.contributor.author Monsoriu Serra, Juan Antonio es_ES
dc.contributor.author Furlan, Walter D. es_ES
dc.date.accessioned 2020-10-27T04:32:04Z
dc.date.available 2020-10-27T04:32:04Z
dc.date.issued 2020-05-01 es_ES
dc.identifier.issn 1559-128X es_ES
dc.identifier.uri http://hdl.handle.net/10251/153225
dc.description.abstract [EN] A new class of diffraction-based corneal inlays for treatment of presbyopia is described. The inlay is intended to achieve an improvement of the near focus quality over previous designs. Our proposal is a two-zone hybrid device with separated amplitude and phase areas having a central aperture and no refractive power. An array of micro-holes is distributed on the surface of the inlay conforming a binary photon sieve. In this way, the central hole of the disk contributes to the zero order of diffraction, and the light diffracted by the micro-holes in the peripheral photon sieve produces a real focus for near vision. We employed ray-tracing software to study the performance of the new inlay in the Liou-Brennan model eye. The modulation transfer functions (MTFs) at the distance and near foci, and the area under the MTFs for different object vergences, were the merit functions used in the evaluation. The results were compared with those obtained with previous pure amplitude designs. Additionally, image simulations were performed with the inlays in the model eye to show the good performance of our proposal in improving the quality of the near vision. (C) 2020 Optical Society of America es_ES
dc.description.sponsorship Ministerio de Economia y Competitividad, Spain (2019/048, DPI 2015-71256-R); Conselleria d'Educacio, Investigacio, Cultura i Esport, Comunitat Valenciana, Spain (PROMETEO/2019/048). Portions of this work were presented at the Optics Meeting (RIAO), the Latinoamerican Meeting in Optics, Lasers and Applications (OPTILAS), and the Mexican Optics and Photonics Meeting (MOPM) in September 2019, Diffractive corneal inlays: ray tracing analysis in a model eye . D. Montagud Martinez and V. Ferrando acknowledge the financial support from the Universitat Politècnica de València, Spain (fellowships FPI 2016 and PAID 10 18, respectively). es_ES
dc.language Inglés es_ES
dc.publisher The Optical Society es_ES
dc.relation.ispartof Applied Optics es_ES
dc.rights Reserva de todos los derechos es_ES
dc.subject.classification FISICA APLICADA es_ES
dc.title Proposal of a new diffractive corneal inlay to improve near vision in a presbyopic eye es_ES
dc.type Artículo es_ES
dc.identifier.doi 10.1364/AO.383581 es_ES
dc.relation.projectID info:eu-repo/grantAgreement/GVA//PROMETEO%2F2019%2F048/ es_ES
dc.relation.projectID info:eu-repo/grantAgreement/MINECO//DPI2015-71256-R/ES/DISEÑO Y OPTIMIZACION DE LENTES INTRACORNEALES DIFRACTIVAS MULTIFOCALES PARA EL TRATAMIENTO DE LA PRESBICIA/ es_ES
dc.rights.accessRights Abierto es_ES
dc.contributor.affiliation Universitat Politècnica de València. Departamento de Física Aplicada - Departament de Física Aplicada es_ES
dc.description.bibliographicCitation Montagud-Martínez, D.; Ferrando, V.; Monsoriu Serra, JA.; Furlan, WD. (2020). Proposal of a new diffractive corneal inlay to improve near vision in a presbyopic eye. Applied Optics. 59(13):D54-D58. https://doi.org/10.1364/AO.383581 es_ES
dc.description.accrualMethod S es_ES
dc.relation.publisherversion https://doi.org/10.1364/AO.383581 es_ES
dc.description.upvformatpinicio D54 es_ES
dc.description.upvformatpfin D58 es_ES
dc.type.version info:eu-repo/semantics/publishedVersion es_ES
dc.description.volume 59 es_ES
dc.description.issue 13 es_ES
dc.identifier.pmid 32400623 es_ES
dc.relation.pasarela S\405106 es_ES
dc.contributor.funder Generalitat Valenciana es_ES
dc.contributor.funder Ministerio de Economía y Competitividad es_ES
dc.description.references Lindstrom, R. L., MacRae, S. M., Pepose, J. S., & Hoopes, P. C. (2013). Corneal inlays for presbyopia correction. Current Opinion in Ophthalmology, 24(4), 281-287. doi:10.1097/icu.0b013e328362293e es_ES
dc.description.references Charman, W. N. (2014). Developments in the correction of presbyopia II: surgical approaches. Ophthalmic and Physiological Optics, 34(4), 397-426. doi:10.1111/opo.12129 es_ES
dc.description.references Furlan, W. D., García-Delpech, S., Udaondo, P., Remón, L., Ferrando, V., & Monsoriu, J. A. (2017). Diffractive corneal inlay for presbyopia. Journal of Biophotonics, 10(9), 1110-1114. doi:10.1002/jbio.201600320 es_ES
dc.description.references Kipp, L., Skibowski, M., Johnson, R. L., Berndt, R., Adelung, R., Harm, S., & Seemann, R. (2001). Sharper images by focusing soft X-rays with photon sieves. Nature, 414(6860), 184-188. doi:10.1038/35102526 es_ES
dc.description.references Giménez, F., Monsoriu, J. A., Furlan, W. D., & Pons, A. (2006). Fractal photon sieve. Optics Express, 14(25), 11958. doi:10.1364/oe.14.011958 es_ES
dc.description.references Montagud-Martinez, D., Ferrando, V., Machado, F., Monsoriu, J. A., & Furlan, W. D. (2019). Imaging Performance of a Diffractive Corneal Inlay for Presbyopia in a Model Eye. IEEE Access, 7, 163933-163938. doi:10.1109/access.2019.2949223 es_ES
dc.description.references Montagud-Martínez, D., Ferrando, V., Monsoriu, J. A., & Furlan, W. D. (2019). Optical Evaluation of New Designs of Multifocal Diffractive Corneal Inlays. Journal of Ophthalmology, 2019, 1-6. doi:10.1155/2019/9382467 es_ES
dc.description.references Liou, H.-L., & Brennan, N. A. (1997). Anatomically accurate, finite model eye for optical modeling. Journal of the Optical Society of America A, 14(8), 1684. doi:10.1364/josaa.14.001684 es_ES
dc.description.references Alarcon, A., Canovas, C., Rosen, R., Weeber, H., Tsai, L., Hileman, K., & Piers, P. (2016). Preclinical metrics to predict through-focus visual acuity for pseudophakic patients. Biomedical Optics Express, 7(5), 1877. doi:10.1364/boe.7.001877 es_ES
dc.subject.ods 03.- Garantizar una vida saludable y promover el bienestar para todos y todas en todas las edades es_ES


Este ítem aparece en la(s) siguiente(s) colección(ones)

Mostrar el registro sencillo del ítem