Experimental investigation on camera calibration for 3D photogrammetric scanning of micro-features for micrometric resolution

RiuNet: Repositorio Institucional de la Universidad Politécnica de Valencia

Compartir/Enviar a

Citas

Estadísticas

  • Estadisticas de Uso

Experimental investigation on camera calibration for 3D photogrammetric scanning of micro-features for micrometric resolution

Mostrar el registro completo del ítem

Percoco, G.; Guerra, MG.; Sánchez Salmerón, AJ.; Galantucci, LM. (2017). Experimental investigation on camera calibration for 3D photogrammetric scanning of micro-features for micrometric resolution. The International Journal of Advanced Manufacturing Technology. 91(9-12):2935-2947. https://doi.org/10.1007/s00170-016-9949-6

Por favor, use este identificador para citar o enlazar este ítem: http://hdl.handle.net/10251/153777

Ficheros en el ítem

Metadatos del ítem

Título: Experimental investigation on camera calibration for 3D photogrammetric scanning of micro-features for micrometric resolution
Autor: Percoco, Gianluca Guerra, Maria Grazia Sánchez Salmerón, Antonio José Galantucci, Luigi Maria
Entidad UPV: Universitat Politècnica de València. Departamento de Ingeniería de Sistemas y Automática - Departament d'Enginyeria de Sistemes i Automàtica
Fecha difusión:
Resumen:
[EN] Recently, it has been demonstrated that photogrammetry can be used for the measurement of small objects with micro-features, with good results and lower cost, compared to other established techniques such as interferometry, ...[+]
Palabras clave: Calibration , Reprojection error , 3D photogrammetric scanning , Micro-features
Derechos de uso: Reserva de todos los derechos
Fuente:
The International Journal of Advanced Manufacturing Technology. (issn: 0268-3768 )
DOI: 10.1007/s00170-016-9949-6
Editorial:
Springer-Verlag
Versión del editor: https://doi.org/10.1007/s00170-016-9949-6
Tipo: Artículo

References

Uhlmann E, Mullany B, Biermann D, Rajurkar KP, Hausotte T, Brinksmeier E (2016) Process chains for high-precision components with micro-scale features. CIRP Ann - Manuf Technol 65:549–572. doi: 10.1016/j.cirp.2016.05.001

Savio E, De Chiffre L, Schmitt R (2007) Metrology of freeform shaped parts. CIRP Ann - Manuf Technol 56:810–835. doi: 10.1016/j.cirp.2007.10.008

Rodríguez-martín M, Lagüela S, González-aguilera D, Rodríguez-gonzálvez P (2015) Optics & Laser Technology Procedure for quality inspection of welds based on macro-photogrammetric three-dimensional reconstruction;73:54–62 [+]
Uhlmann E, Mullany B, Biermann D, Rajurkar KP, Hausotte T, Brinksmeier E (2016) Process chains for high-precision components with micro-scale features. CIRP Ann - Manuf Technol 65:549–572. doi: 10.1016/j.cirp.2016.05.001

Savio E, De Chiffre L, Schmitt R (2007) Metrology of freeform shaped parts. CIRP Ann - Manuf Technol 56:810–835. doi: 10.1016/j.cirp.2007.10.008

Rodríguez-martín M, Lagüela S, González-aguilera D, Rodríguez-gonzálvez P (2015) Optics & Laser Technology Procedure for quality inspection of welds based on macro-photogrammetric three-dimensional reconstruction;73:54–62

Xu Z, Toncich D, Stefani S (1999) Vision-based measurement of three-dimensional geometric workpiece properties. Int J Adv Manuf Technol 15:322–331. doi: 10.1007/s001700050074

Galantucci LM, Lavecchia F, Percoco G (2013) Multistack close range photogrammetry for low cost submillimeter metrology. J Comput Inf Sci Eng 13:44501. doi: 10.1115/1.4024973

Maté González, M.T., Yravedra, J., González-Aguilera, D., Palomeque-González, J.F., Domínguez-Rodrigo, M. Micro-photogrammetric characterization of cut marks on bones (2015) Journal of Archaeological Science, 62, pp. 128-142. doi: 10.1016/j.jas.2015.08.006

Brown DC (1971) Close-range camera calibration. Photogramm Eng 37:855–866 doi:10.1.1.14.6358

Tang R, Fritsch D (2013) Correlation analysis of camera self-calibration in close range photogrammetry. Photogramm Rec 28:86–95. doi: 10.1111/phor.12009

Agisoft LLC (2011) Agisoft PhotoScan User Manual :37.

Jcgm JCFGIM (2008) Evaluation of measurement data—guide to the expression of uncertainty in measurement- annex B "general metrological terms"- B.2.14. Int Organ Stand Geneva ISBN 50:134. doi: 10.1373/clinchem.2003.030528

Yanagi, H., Chikatsu, H. Performance evaluation of macro lens in digital close range photogrammetry (2009) Proceedings of SPIE - The International Society for Optical Engineering, 7447, art. no. 74470J, doi: 10.1117/12.825817

Galantucci LM, Pesce M, Lavecchia F (2015) A stereo photogrammetry scanning methodology, for precise and accurate 3D digitization of small parts with sub-millimeter sized features. CIRP Ann - Manuf Technol 64:507–510. doi: 10.1016/j.cirp.2015.04.016

Galantucci LM, Pesce M, Lavecchia F (2015) A powerful scanning methodology for 3D measurements of small parts with complex surfaces and sub millimeter-sized features, based on close range photogrammetry. Precis Eng. doi: 10.1016/j.precisioneng.2015.07.010

Percoco G, Sánchez Salmerón AJ (2015) Photogrammetric measurement of 3D freeform millimetre-sized objects with micro features: an experimental validation of the close-range camera calibration model for narrow angles of view. Meas Sci Technol 26:95203. doi: 10.1088/0957-0233/26/9/095203

Gallo A, Muzzupappa M, Bruno F (2014) 3D reconstruction of small sized objects from a sequence of multi-focused images. J Cult Herit 15:173–182. doi: 10.1016/j.culher.2013.04.009

Stamatopoulos C, Fraser CS, Cronk S (2010) On the self-calibration of long focal length lenses. Int Arch Photogramm Remote Sens Spat Inf Sci Newcastle upon Tyne, UK 2010 XXXVIII:560–564

Atkinson KB (1996) Close range photogrammetry and machine vision. Whittles Publishing

Luhmann T, Fraser C, Maas HG (2016) Sensor modelling and camera calibration for close-range photogrammetry. ISPRS J Photogramm Remote Sens 115:37–46. doi: 10.1016/j.isprsjprs.2015.10.006

Tsai RY (1986) An efficient and accurate camera calibration technique for 3D machine vision. Proc IEEE Conf Comput Vis Pattern Recognition 1986

Ricolfe-Viala C, Sanchez-Salmeron A-J (2011) Camera calibration under optimal conditions. Opt Express 19:10769–10775. doi: 10.1364/OE.19.010769

Wang L, Wang W, Shen C, Duan F (2016) A convex relaxation optimization algorithm for multi-camera calibration with 1D objects. Neurocomputing

Ricolfe-Viala C, Sanchez-Salmeron A. Lens distortion models evaluation. Appl Opt 2010;49:5914–5928.

Percoco G, Lavecchia F, Salmerón AJS (2015) Preliminary study on the 3D digitization of millimeter scale products by means of photogrammetry. Procedia CIRP 33:257–262. doi: 10.1016/j.procir.2015.06.046

Bradski G (2000) The OpenCV Library. Dr Dobb’s J Softw Tools

Ricolfe-Viala C, Sanchez-Salmeron A-J (2011) Optimal conditions for camera calibration using a planar template. 2011 18th IEEE. Int Conf Image Process, IEEE 2011:853–856. doi: 10.1109/ICIP.2011.6116691

Lowe DG (1999) Object recognition from local scale-invariant features. Proc Seventh IEEE Int Conf Comput Vis 2:1150–1157. doi: 10.1109/ICCV.1999.790410

Triggs B, Mclauchlan P, Hartley R, Fitzgibbon A, Triggs B, Mclauchlan P, et al. (2010) Bundle adjustment—a modern synthesis to cite this version: bundle adjustment—a modern synthesis

Cignoni P, Callieri M, Corsini M, Dellepiane M, Ganovelli F, Ranzuglia G (2008) Meshlab: an open-source mesh processing tool. Eurographics Ital Chapter Conf 2008:129–136

Besl P, McKay N (1992) A method for registration of 3-D shapes. IEEE Trans Pattern Anal Mach Intell 14:239–256. doi: 10.1109/34.121791

[-]

recommendations

 

Este ítem aparece en la(s) siguiente(s) colección(ones)

Mostrar el registro completo del ítem