Electrostatical and thermal design of the insulation in a high voltage permanent magnet generator

RiuNet: Repositorio Institucional de la Universidad Politécnica de Valencia

Compartir/Enviar a

Citas

Estadísticas

  • Estadisticas de Uso

Electrostatical and thermal design of the insulation in a high voltage permanent magnet generator

Mostrar el registro sencillo del ítem

Ficheros en el ítem

dc.contributor.advisor Quijano Lopez, Alfredo es_ES
dc.contributor.advisor Thiringer, Törbjorn es_ES
dc.contributor.author Segarra Valenzuela, Mar es_ES
dc.date.accessioned 2020-11-13T12:53:57Z
dc.date.available 2020-11-13T12:53:57Z
dc.date.created 2020-07-30
dc.date.issued 2020-11-13 es_ES
dc.identifier.uri http://hdl.handle.net/10251/155040
dc.description.abstract [ES] Se trata del diseño del aislamiento de un generador de imanes permanentes de corriente alterna que trabaja a alto voltage, en primer lugar he realizado el diseño electróstatico para verificar que el material aislante(mica) resiste el campo eléctrico al que está sometido, y en segundo lugar he realizado el análisis térmico con ansys Fluent , pues las temperaturas que se alcanzan a ese voltaje son muy altas. Consta de un primer análisis sin refrigeración directa, en esta parte el calor se evacua por conducción y por convección con el aire exterior y el aire en el air gap entre el rotor y el estátor y de una segunda parte donde añado un canal de refrigeración en el interior de cada bobina para reducir más la temperatura. Por último, una de mis supervisoras unirá su simulación electromagnética, el calor que se genera debido a esto, con mi simulación térmica para acabar de analizar el generador completamente. Todo esto lo realizo basándome en simplificaciones por simetría y analizo un solo polo del generador en 2D. es_ES
dc.description.abstract [EN] This thesis covers the electrostatical analysis and design of the insulation, performed by means of Matlab and Ansys Maxwell as well as the thermal analysis and design by Ansys Fluent. Both analysis have been done first by calculating analytical approximations and then by simulating the generator under different operating conditions. The approach is quite conservative since the aim of this thesis is to verify that the cool down of an electric machine of this characteristics would be possible. Thermal resistance networks coupled with Ansys Fluent have been used to analyse the heat transfer inside the machine. Based on the electrostatic analysis, the minimum insulation thickness was designed, a thickness of 1mm in the turn insulation and another milimeter for the groundwall, with this configuration, cooling down the generator with an air cooling system was unfeasible, thus a cooling channel that went through the slots was designed, both the analytical and the numerical analysis verified that the heat was easily evacuated when introducing a water cooling channel inside the slots. es_ES
dc.format.extent 76 es_ES
dc.language Inglés es_ES
dc.publisher Universitat Politècnica de València es_ES
dc.rights Reserva de todos los derechos es_ES
dc.subject Movilidad es_ES
dc.subject Diseño es_ES
dc.subject Generador es_ES
dc.subject Aislamiento es_ES
dc.subject Análisis electrostático es_ES
dc.subject Análisis térmico es_ES
dc.subject Ansys es_ES
dc.subject Matlab es_ES
dc.subject CFD es_ES
dc.subject Electromagnetismo computacional. es_ES
dc.subject Erasmus es_ES
dc.subject Design es_ES
dc.subject Insulation es_ES
dc.subject Generator es_ES
dc.subject Electrostatic analysis es_ES
dc.subject Thermal analysis es_ES
dc.subject Computational electromagnetics es_ES
dc.subject High voltage es_ES
dc.subject numerical simulation es_ES
dc.subject insulation design es_ES
dc.subject.classification INGENIERIA ELECTRICA es_ES
dc.subject.other Grado en Ingeniería en Tecnologías Industriales-Grau en Enginyeria en Tecnologies Industrials es_ES
dc.title Electrostatical and thermal design of the insulation in a high voltage permanent magnet generator es_ES
dc.title.alternative Diseño del aislamiento del generador de alto voltage, de una turbina eólica en altamar, mediante el análisis electrostático y térmico del mismo usando Ansys Maxwell, Ansys Fluent, y Matlab. es_ES
dc.type Proyecto/Trabajo fin de carrera/grado es_ES
dc.rights.accessRights Abierto es_ES
dc.contributor.affiliation Universitat Politècnica de València. Departamento de Ingeniería Eléctrica - Departament d'Enginyeria Elèctrica es_ES
dc.contributor.affiliation Universitat Politècnica de València. Escuela Técnica Superior de Ingenieros Industriales - Escola Tècnica Superior d'Enginyers Industrials es_ES
dc.description.bibliographicCitation Segarra Valenzuela, M. (2020). Electrostatical and thermal design of the insulation in a high voltage permanent magnet generator. http://hdl.handle.net/10251/155040 es_ES
dc.description.accrualMethod TFGM es_ES
dc.relation.pasarela TFGM\131760 es_ES


Este ítem aparece en la(s) siguiente(s) colección(ones)

Mostrar el registro sencillo del ítem