- -

Optimisation of ultrasound liver perfusion through a digital reference object and analysis tool

RiuNet: Repositorio Institucional de la Universidad Politécnica de Valencia

Compartir/Enviar a

Citas

Estadísticas

  • Estadisticas de Uso

Optimisation of ultrasound liver perfusion through a digital reference object and analysis tool

Mostrar el registro completo del ítem

Alberich-Bayarri, Á.; Tomás-Cucarella, J.; Torregrosa-Lloret, A.; Saiz Rodríguez, FJ.; Martí-Bonmatí, L. (2019). Optimisation of ultrasound liver perfusion through a digital reference object and analysis tool. European Radiology Experimental. 3:1-10. https://doi.org/10.1186/s41747-019-0086-5

Por favor, use este identificador para citar o enlazar este ítem: http://hdl.handle.net/10251/156427

Ficheros en el ítem

Metadatos del ítem

Título: Optimisation of ultrasound liver perfusion through a digital reference object and analysis tool
Autor: Alberich-Bayarri, Ángel Tomás-Cucarella, Jose Torregrosa-Lloret, Alfredo Saiz Rodríguez, Francisco Javier Martí-Bonmatí, Luis
Entidad UPV: Universitat Politècnica de València. Departamento de Ingeniería Electrónica - Departament d'Enginyeria Electrònica
Fecha difusión:
Resumen:
[EN] Background Conventional ultrasound (US) provides important qualitative information, although there is a need to evaluate the influence of the input parameters on the output signal and standardise the acquisition for ...[+]
Palabras clave: Biomarkers , Liver , Perfusion imaging , Phantoms (imaging) , Ultrasonography
Derechos de uso: Reconocimiento (by)
Fuente:
European Radiology Experimental. (eissn: 2509-9280 )
DOI: 10.1186/s41747-019-0086-5
Editorial:
Springer
Versión del editor: https://doi.org/10.1186/s41747-019-0086-5
Tipo: Artículo

References

Parker JM, Weller MW, Feinstein LM et al (2013) Safety of ultrasound contrast agents in patients with known or suspected cardiac shunts. Am J Cardiol 112:1039–1045.

Dhamija E, Paul SB (2014) Role of contrast enhanced ultrasound in hepatic imaging. Trop Gastroenterol 35:141–151.

Wang XY, Kang LK, Lan CY (2014) Contrast-enhanced ultrasonography in diagnosis of benign and malignant breast lesions. Eur J Gynaecol Oncol 35:415–420. [+]
Parker JM, Weller MW, Feinstein LM et al (2013) Safety of ultrasound contrast agents in patients with known or suspected cardiac shunts. Am J Cardiol 112:1039–1045.

Dhamija E, Paul SB (2014) Role of contrast enhanced ultrasound in hepatic imaging. Trop Gastroenterol 35:141–151.

Wang XY, Kang LK, Lan CY (2014) Contrast-enhanced ultrasonography in diagnosis of benign and malignant breast lesions. Eur J Gynaecol Oncol 35:415–420.

Wang S, Yang W, Zhang H, Xu Q, Yan K (2015) The role of contrast-enhanced ultrasound in selection indication and improveing diagnosis for transthoracic biopsy in peripheral pulmonary and mediastinal lesions. Biomed Res Int 2015:231782.

Green MA, Mathias CJ, Willis LR, et al (2007) Assessment of Cu-ETS as a PET radiopharmaceutical for evaluation of regional renal perfusion. Nucl Med Biol 34:247–255.

Daghini E, Primak AN, Chade AR, et al (2007) Assessment of renal hemodynamics and function in pigs with 64-section multidetector CT: comparison with electron-beam CT. Radiology 243:405–412.

Martin DR, Sharma P, Salman K, et al (2008) Individual kidney blood flow measured with contrast-enhanced first-pass perfusion MR imaging. Radiology 246:241–248.

Tang MX, Mulvana H, Gauthier T, et al (2011) Quantitative contrast-enhanced ultrasound imaging: a review of sources of variability. Interface Focus 1:520–539.

Gauthier TP, Averkiou MA, Leen EL (2011) Perfusion quantification using dynamic contrast-enhanced ultrasound: the impact of dynamic range and gain on time-intensity curves. Ultrasonics 51:102–106.

Möller I, Janta I, Backhaus M, et al (2017) The 2017 EULAR standardised procedures for ultrasound imaging in rheumatology. Ann Rheum Dis. 76:1974–1979.

Pitre-Champagnat S, Coiffier B, Jourdain L, Benatsou B, Leguerney I, Lassau N (2017) Toward a standardization of ultrasound scanners for dynamic contrast-enhanced ultrasonography: methodology and phantoms. Ultrasound Med Biol. https://doi.org/10.1016/j.ultrasmedbio.2017.06.032

Shunichi S, Hiroko I, Fuminori M, Waki H (2009) Definition of contrast enhancement phases of the liver using a perfluoro-based microbubble agent, perflubutane microbubbles. Ultrasound Med Biol 35:1819–1827. doi

Fairbank WM Jr, Scully MO (1977) A new noninvasive technique for cardiac pressure measurement: resonant scattering of ultrasound from bubbles. IEEE Trans Biomed Eng 24:107–110.

Malm S, Frigstad S, Helland F, Oye K, Slordahl S, Skjarpe T (2005) Quantification of resting myocardial blood flow velocity in normal humans using real-time contrast echocardiography. A feasibility study. Cardiovasc Ultrasound 3:16.

Arditi M, Frinking PJ, Zhou X, Rognin NG (2006) A new formalism for the quantification of tissue perfusion by the destruction-replenishment method in contrast ultrasound imaging. IEEE Trans Ultrason Ferroelectr Freq Control 53:1118–1129.

Savic RM, Jonker DM, Kerbusch T, Karlsson MO (2007) Implementation of a transit compartment model for describing drug absorption in pharmacokinetic studies. J Pharmacokinet Pharmacodyn 34:711–726.

Averkiou M, Lampaskis M, Kyriakopoulou K, et al (2010) Quantification of tumor microvascularity with respiratory gated contrast enhanced ultrasound for monitoring therapy. Ultrasound Med Biol 36:68–77.

Kuenen MP, Mischi M, Wijkstra H (2011) Contrast-ultrasound diffusion imaging for localization of prostate cancer. IEEE Trans Med Imaging 30:1493–1502.

Garcia D, Le Tarnec L, Muth S, Montagnon E, Porée J, Cloutier G(2013) Stolt’s f-k migration for plane wave ultrasound imaging. IEEE Trans Ultrason Ferroelectr Freq Control 60:1853–1867.

Brands J, Vink H, Van Teeffelen JW (2011) Comparison of four mathematical models to analyze indicator-dilution curves in the coronary circulation. Med Biol Eng Comput 49:1471–1479.

Zhou JH, Cao LH, Zheng W, Liu M, Han F, Li AH (2011) Contrast-enhanced gray-scale ultrasound for quantitative evaluation of tumor response to chemotherapy: preliminary results with a mouse hepatoma model. AJR Am J Roentgenol 196:W13-17.

Wei K, Jayaweera AR, Firoozan S, Linka A, Skyba DM, Kaul S (1998) Quantification of myocardial blood flow with ultrasoundinduced destruction of microbubbles administered as a constant venous infusion. Circulation 97:473–483

Riascos P, Velasco-Medina J (2005) Efectos Biológicos y Consideraciones de Seguridad en Ultrasonido. Available via https://www.yumpu.com/es/document/view/15350629/efectos-biologicos-y-consideraciones-de-seguridad-en-ultrasonido

de Jong N, ten Cate FJ, Vletter WB, Roelandt JR (1993) Quantification of transpulmonary echocontrast effects. Ultrasound Med Biol 19:279–288

Quaia E (2011) Assessment of tissue perfusion by contrast-enhanced ultrasound. Eur Radiol 21:604–615.

[-]

recommendations

 

Este ítem aparece en la(s) siguiente(s) colección(ones)

Mostrar el registro completo del ítem