Desarrollo de un método para la estimación de la ubicación de lugares mantenedores de la fibrilación auricular mediante problema inverso de la electrocardiografía mediante análisis de fase y modulaciones en fase y frecuencia

Mostrar el registro sencillo del ítem

Ficheros en el ítem

dc.contributor.advisor Guillem Sánchez, María Salud es_ES
dc.contributor.advisor Molero Alabau, Rubén es_ES
dc.contributor.author Ballester Hoyo, Estrella del Mar es_ES
dc.date.accessioned 2021-01-14T18:06:04Z
dc.date.available 2021-01-14T18:06:04Z
dc.date.created 2020-12-09
dc.date.issued 2021-01-14 es_ES
dc.identifier.uri http://hdl.handle.net/10251/159115
dc.description.abstract [ES] La Fibrilación Auricular (FA) es la arritmia más frecuente observada en clínica. En casos en los que esta patología no revierte debido a la actividad reentrante se suele recurrir al tratamiento por ablación mediante catéter. Pero se trata de una técnica invasiva, y con ello surge la necesidad de diseñar métodos que aumenten su tasa de éxito identificando de manera precisa las zonas mantenedoras de la FA. Actualmente, los algoritmos más empleados para identificar dichas regiones son los basados en localización de singularidades de fase (SPs), pero existen métodos alternativos. En el presente trabajo se ha programado un algoritmo basado en el análisis de fase y modulaciones en amplitud y frecuencia instantáneas (iAM e iFM) para detectar regiones de actividad reentrante sobre una base de datos con 30 electrogramas (EGM) de simulación y otra base de datos con 24 señales de imagen electrocardiográfica (ECGi) de pacientes, obtenidas mediante Body Surface Potential Mapping (BSPM) y con el problema inverso calculado. Además, se han comparado los resultados obtenidos con el Gold Standard para simulación y con los calculados mediante un algoritmo basado en la detección de SPs en pacientes. Se han empleado métricas para evaluar su capacidad de detección, los indicadores de subestimación ponderada (WUI) y de sobreestimación (WOI). Los mínimos WUI han resultado de 88,16 % y 52,16 % y de WOI de 0 % y 6,9 %, en simulación y pacientes respectivamente, lo cual indica que las características de las señales de entrada y sus métodos de adquisición podrían afectar a la capacidad de detección de actividad reentrante de los métodos basados en iAM e iFM. Se han mejorado los tiempos de cálculo obteniéndose una media de 31.12 s frente a 56.17 s en simulación, y de 86.97 s frente a 97.03 s en pacientes, para el algoritmo programado y el basado en SPs respectivamente. es_ES
dc.description.abstract [EN] Atrial Fibrillation (AF) is the most frequent arrythmia observed in clinical practice. In cases in which this pathology does not reverse due to reentrant activity, treatment by catheter ablation is usually used. But this is an invasive technique and with this arises the need to design new methods that increase its success rate by precisely identifying the maintaining areas of the AF. Currently, the most used algorithms to identify those regions are the ones based on the location of phase singularities (SPs), but there are alternative methods. In the present study, it has been programmed an algorithm based on phase and instantaneous amplitude and frequency modulations (iAM and iFM) analysis to detect reentrant activity regions on a database with 30 simulation electrograms (EGM) and another database with 24 electrocardiographic image signals (ECGi) of patients, obtained by Body Surface Potential Mapping (BSPM) and with the inverse problem calculated. Furthermore, the results obtained have been compared with the Gold Standard for simulation and with those calculated using an SPs detection based algorithm in patients. To evaluate its detection capacity, specific metrics have been used; the weighted underestimation indicator (WUI) and the weighted overestimation indicator (WOI). The minimum WUI have been 88.16% and 52.16% and WOI of 0% and 6.9%, in simulation and patients respectively, which indicates that the characteristics of the input signals and their acquisition methods could affect the reentrant activity detection ability of iAM and iFM based methods. Computing times have been improved, obtaining an average of 31.12 s versus 56.17 s in simulation, and 86.97 s versus 97.03 s in patients, for the programmed algorithm and the one based on SPs respectively. es_ES
dc.format.extent 74 es_ES
dc.language Español es_ES
dc.publisher Universitat Politècnica de València es_ES
dc.rights Reserva de todos los derechos es_ES
dc.subject Cardiología es_ES
dc.subject Fibrilación Auricular es_ES
dc.subject Modulación en amplitud es_ES
dc.subject Modulación en frecuencia es_ES
dc.subject Rotor es_ES
dc.subject EGM es_ES
dc.subject ECGi es_ES
dc.subject Problema Inverso es_ES
dc.subject Ablación es_ES
dc.subject WUI es_ES
dc.subject WOI es_ES
dc.subject Cardiology es_ES
dc.subject Atrial Fibrillation es_ES
dc.subject Amplitude Modulation es_ES
dc.subject Frequency Modulation es_ES
dc.subject Inverse Problem es_ES
dc.subject Ablation es_ES
dc.subject.classification TECNOLOGIA ELECTRONICA es_ES
dc.subject.other Grado en Ingeniería Biomédica-Grau en Enginyeria Biomèdica es_ES
dc.title Desarrollo de un método para la estimación de la ubicación de lugares mantenedores de la fibrilación auricular mediante problema inverso de la electrocardiografía mediante análisis de fase y modulaciones en fase y frecuencia es_ES
dc.type Proyecto/Trabajo fin de carrera/grado es_ES
dc.rights.accessRights Abierto es_ES
dc.contributor.affiliation Universitat Politècnica de València. Departamento de Ingeniería Electrónica - Departament d'Enginyeria Electrònica es_ES
dc.contributor.affiliation Universitat Politècnica de València. Escuela Técnica Superior de Ingenieros Industriales - Escola Tècnica Superior d'Enginyers Industrials es_ES
dc.description.bibliographicCitation Ballester Hoyo, EDM. (2020). Desarrollo de un método para la estimación de la ubicación de lugares mantenedores de la fibrilación auricular mediante problema inverso de la electrocardiografía mediante análisis de fase y modulaciones en fase y frecuencia. Universitat Politècnica de València. http://hdl.handle.net/10251/159115 es_ES
dc.description.accrualMethod TFGM es_ES
dc.relation.pasarela TFGM\133711 es_ES


Este ítem aparece en la(s) siguiente(s) colección(ones)

Mostrar el registro sencillo del ítem