M-Bonacci Zone Plates for Ultrasound Focusing

RiuNet: Repositorio Institucional de la Universidad Politécnica de Valencia

Compartir/Enviar a

Citas

Estadísticas

  • Estadisticas de Uso

M-Bonacci Zone Plates for Ultrasound Focusing

Mostrar el registro sencillo del ítem

Ficheros en el ítem

dc.contributor.author Pérez-López, Sergio es_ES
dc.contributor.author Fuster Escuder, José Miguel es_ES
dc.contributor.author Candelas Valiente, Pilar es_ES
dc.date.accessioned 2021-02-03T04:32:44Z
dc.date.available 2021-02-03T04:32:44Z
dc.date.issued 2019-10 es_ES
dc.identifier.uri http://hdl.handle.net/10251/160578
dc.description.abstract [EN] In this work, we present a thorough analysis on M-bonacci zone plates for ultrasound focusing applications. These planar lenses are capable of providing bifocal focusing profiles with equal intensity in both foci and become very appealing for a wide range of scenarios including medical and industrial applications. We show that in high-wavelength domains, such as acoustics or microwaves, the separation between both foci can be finely adjusted at the expense of slightly increasing the distortion of the focusing profile, and we introduce a design parameter to deal with this issue and simplify the design process of these lenses. Experimental measurements are in good agreement with numerical simulations and demonstrate the potential of M-bonacci lenses in ultrasound focusing applications. es_ES
dc.description.sponsorship This work has been supported by Spanish MICINN RTI2018-100792-B-I00 project. S.P.-L. acknowledges financial support from Universitat Politecnica de Valencia grant program PAID-01-18. es_ES
dc.language Inglés es_ES
dc.publisher MDPI AG es_ES
dc.relation.ispartof Sensors es_ES
dc.rights Reconocimiento (by) es_ES
dc.subject M-bonacci zone plate es_ES
dc.subject Fresnel zone plate es_ES
dc.subject Acoustic focusing es_ES
dc.subject Acoustic lens es_ES
dc.subject.classification TEORIA DE LA SEÑAL Y COMUNICACIONES es_ES
dc.subject.classification FISICA APLICADA es_ES
dc.title M-Bonacci Zone Plates for Ultrasound Focusing es_ES
dc.type Artículo es_ES
dc.identifier.doi 10.3390/s19194313 es_ES
dc.relation.projectID info:eu-repo/grantAgreement/UPV//PAID-01-18/ es_ES
dc.relation.projectID info:eu-repo/grantAgreement/AEI/Plan Estatal de Investigación Científica y Técnica y de Innovación 2017-2020/RTI2018-100792-B-I00/ES/FOCALIZACION Y CONFORMACION DE HACES DE ULTRASONIDOS MEDIANTE LENTES PLANAS/ es_ES
dc.rights.accessRights Abierto es_ES
dc.contributor.affiliation Universitat Politècnica de València. Departamento de Comunicaciones - Departament de Comunicacions es_ES
dc.contributor.affiliation Universitat Politècnica de València. Departamento de Física Aplicada - Departament de Física Aplicada es_ES
dc.description.bibliographicCitation Pérez-López, S.; Fuster Escuder, JM.; Candelas Valiente, P. (2019). M-Bonacci Zone Plates for Ultrasound Focusing. Sensors. 19(19):1-13. https://doi.org/10.3390/s19194313 es_ES
dc.description.accrualMethod S es_ES
dc.relation.publisherversion https://doi.org/10.3390/s19194313 es_ES
dc.description.upvformatpinicio 1 es_ES
dc.description.upvformatpfin 13 es_ES
dc.type.version info:eu-repo/semantics/publishedVersion es_ES
dc.description.volume 19 es_ES
dc.description.issue 19 es_ES
dc.identifier.eissn 1424-8220 es_ES
dc.identifier.pmid 31590375 es_ES
dc.identifier.pmcid PMC6806303 es_ES
dc.relation.pasarela S\394747 es_ES
dc.contributor.funder Universitat Politècnica de València es_ES
dc.contributor.funder Agencia Estatal de Investigación es_ES
dc.description.references Chen, J., Xiao, J., Lisevych, D., Shakouri, A., & Fan, Z. (2018). Deep-subwavelength control of acoustic waves in an ultra-compact metasurface lens. Nature Communications, 9(1). doi:10.1038/s41467-018-07315-6 es_ES
dc.description.references Molerón, M., Serra-Garcia, M., & Daraio, C. (2014). Acoustic Fresnel lenses with extraordinary transmission. Applied Physics Letters, 105(11), 114109. doi:10.1063/1.4896276 es_ES
dc.description.references Li, Y., Yu, G., Liang, B., Zou, X., Li, G., Cheng, S., & Cheng, J. (2014). Three-dimensional Ultrathin Planar Lenses by Acoustic Metamaterials. Scientific Reports, 4(1). doi:10.1038/srep06830 es_ES
dc.description.references Lan, J., Li, Y., Xu, Y., & Liu, X. (2017). Manipulation of acoustic wavefront by gradient metasurface based on Helmholtz Resonators. Scientific Reports, 7(1). doi:10.1038/s41598-017-10781-5 es_ES
dc.description.references Jiménez-Gambín, S., Jiménez, N., Benlloch, J. M., & Camarena, F. (2019). Holograms to Focus Arbitrary Ultrasonic Fields through the Skull. Physical Review Applied, 12(1). doi:10.1103/physrevapplied.12.014016 es_ES
dc.description.references Pérez-López, S., Fuster, J. M., Minin, I. V., Minin, O. V., & Candelas, P. (2019). Tunable subwavelength ultrasound focusing in mesoscale spherical lenses using liquid mixtures. Scientific Reports, 9(1). doi:10.1038/s41598-019-50019-0 es_ES
dc.description.references Veira Canle, D., Kekkonen, T., Mäkinen, J., Puranen, T., Nieminen, H. J., Kuronen, A., … Hæggström, E. (2019). Practical realization of a sub-λ/2 acoustic jet. Scientific Reports, 9(1). doi:10.1038/s41598-019-41335-6 es_ES
dc.description.references Calvo, D. C., Thangawng, A. L., Nicholas, M., & Layman, C. N. (2015). Thin Fresnel zone plate lenses for focusing underwater sound. Applied Physics Letters, 107(1), 014103. doi:10.1063/1.4926607 es_ES
dc.description.references Pérez-López, S., Fuster, J. M., Candelas, P., Rubio, C., & Belmar, F. (2018). On the use of phase correction rings on Fresnel zone plates with ultrasound piston emitters. Applied Physics Letters, 112(26), 264102. doi:10.1063/1.5036712 es_ES
dc.description.references Tarrazó-Serrano, D., Pérez-López, S., Candelas, P., Uris, A., & Rubio, C. (2019). Acoustic Focusing Enhancement In Fresnel Zone Plate Lenses. Scientific Reports, 9(1). doi:10.1038/s41598-019-43495-x es_ES
dc.description.references Rodrigues Ribeiro, R. S., Dahal, P., Guerreiro, A., Jorge, P. A. S., & Viegas, J. (2017). Fabrication of Fresnel plates on optical fibres by FIB milling for optical trapping, manipulation and detection of single cells. Scientific Reports, 7(1). doi:10.1038/s41598-017-04490-2 es_ES
dc.description.references Hristov, H. D., & Rodriguez, J. M. (2012). Design Equation for Multidielectric Fresnel Zone Plate Lens. IEEE Microwave and Wireless Components Letters, 22(11), 574-576. doi:10.1109/lmwc.2012.2224099 es_ES
dc.description.references Clement, G., Nomura, H., & Kamakura, T. (2015). Ultrasound field measurement using a binary lens. IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control, 62(2), 350-359. doi:10.1109/tuffc.2014.006800 es_ES
dc.description.references Pérez-López, S., Fuster, J. M., Candelas, P., & Rubio, C. (2019). On the focusing enhancement of Soret zone plates with ultrasound directional transducers. Applied Physics Letters, 114(22), 224101. doi:10.1063/1.5100219 es_ES
dc.description.references Monsoriu, J. A., Calatayud, A., Remon, L., Furlan, W. D., Saavedra, G., & Andres, P. (2013). Bifocal Fibonacci Diffractive Lenses. IEEE Photonics Journal, 5(3), 3400106-3400106. doi:10.1109/jphot.2013.2248707 es_ES
dc.description.references Machado, F., Ferrando, V., Furlan, W. D., & Monsoriu, J. A. (2017). Diffractive m-bonacci lenses. Optics Express, 25(7), 8267. doi:10.1364/oe.25.008267 es_ES
dc.description.references Saavedra, G., Furlan, W. D., & Monsoriu, J. A. (2003). Fractal zone plates. Optics Letters, 28(12), 971. doi:10.1364/ol.28.000971 es_ES
dc.description.references Furlan, W. D., Saavedra, G., & Monsoriu, J. A. (2007). White-light imaging with fractal zone plates. Optics Letters, 32(15), 2109. doi:10.1364/ol.32.002109 es_ES
dc.description.references Mendoza-Yero, O., Fernández-Alonso, M., Mínguez-Vega, G., Lancis, J., Climent, V., & Monsoriu, J. A. (2009). Fractal generalized zone plates. Journal of the Optical Society of America A, 26(5), 1161. doi:10.1364/josaa.26.001161 es_ES
dc.description.references Ferrando, V., Giménez, F., Furlan, W. D., & Monsoriu, J. A. (2015). Bifractal focusing and imaging properties of Thue–Morse Zone Plates. Optics Express, 23(15), 19846. doi:10.1364/oe.23.019846 es_ES
dc.description.references Xia, T., Cheng, S., & Tao, S. (2018). Generation of three equal-intensity foci based on a modified composite zone plate. Optik, 159, 150-156. doi:10.1016/j.ijleo.2018.01.071 es_ES
dc.description.references Fuster, J., Pérez-López, S., Candelas, P., & Rubio, C. (2018). Design of Binary-Sequence Zone Plates in High Wavelength Domains. Sensors, 18(8), 2604. doi:10.3390/s18082604 es_ES
dc.description.references Nie, L., Cai, X., Maslov, K., Garcia-Uribe, A., Anastasio, M. A., & Wang, L. V. (2012). Photoacoustic tomography through a whole adult human skull with a photon recycler. Journal of Biomedical Optics, 17(11), 110506. doi:10.1117/1.jbo.17.11.110506 es_ES
dc.description.references Chen, M., Knox, H. J., Tang, Y., Liu, W., Nie, L., Chan, J., & Yao, J. (2019). Simultaneous photoacoustic imaging of intravascular and tissue oxygenation. Optics Letters, 44(15), 3773. doi:10.1364/ol.44.003773 es_ES
dc.description.references Ter Haar, >Gail, & Coussios, C. (2007). High intensity focused ultrasound: Physical principles and devices. International Journal of Hyperthermia, 23(2), 89-104. doi:10.1080/02656730601186138 es_ES
dc.description.references Suo, D., Jin, Z., Jiang, X., Dayton, P. A., & Jing, Y. (2017). Microbubble mediated dual-frequency high intensity focused ultrasound thrombolysis: AnIn vitrostudy. Applied Physics Letters, 110(2), 023703. doi:10.1063/1.4973857 es_ES
dc.description.references GyP, S., DY, L., & G, H. (2017). What is on the Horizon for Hyperthermic Cancer Therapy? Journal of Traditional Medicine & Clinical Naturopathy, 06(02). doi:10.4172/2573-4555.1000217 es_ES
dc.description.references Simon, J. C., Sapozhnikov, O. A., Khokhlova, V. A., Wang, Y.-N., Crum, L. A., & Bailey, M. R. (2012). Ultrasonic atomization of tissue and its role in tissue fractionation by high intensity focused ultrasound. Physics in Medicine and Biology, 57(23), 8061-8078. doi:10.1088/0031-9155/57/23/8061 es_ES
dc.description.references Jeong, J. S., Cannata, J. M., & Shung, K. K. (2010). Dual-Focus Therapeutic Ultrasound Transducer for Production of Broad Tissue Lesions. Ultrasound in Medicine & Biology, 36(11), 1836-1848. doi:10.1016/j.ultrasmedbio.2010.08.008 es_ES
dc.description.references Jong Seob Jeong. (2013). Dual concentric-sectored HIFU transducer with phase-shifted ultrasound excitation for expanded necrotic region: a simulation study. IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control, 60(5), 924-931. doi:10.1109/tuffc.2013.2649 es_ES