Estudio de una solución integrada para calefacción y refrigeración en el campus de DTU

RiuNet: Repositorio Institucional de la Universidad Politécnica de Valencia

Compartir/Enviar a

Citas

Estadísticas

  • Estadisticas de Uso

Estudio de una solución integrada para calefacción y refrigeración en el campus de DTU

Mostrar el registro sencillo del ítem

Ficheros en el ítem

dc.contributor.advisor Navarro Peris, Emilio es_ES
dc.contributor.advisor Elmegaard, Brian es_ES
dc.contributor.advisor Schmidt Ommen, Torben es_ES
dc.contributor.advisor Korsgaard Jacobsen, Emil Dybro es_ES
dc.contributor.author Guimarey Docampo, Nerea es_ES
dc.date.accessioned 2021-02-05T10:10:46Z
dc.date.available 2021-02-05T10:10:46Z
dc.date.created 2020-08-27
dc.date.issued 2021-02-05 es_ES
dc.identifier.uri http://hdl.handle.net/10251/160783
dc.description.abstract [ES] El trabajo consiste en un estudio sobre las posibles opciones de suministrar calefacción y refrigeración simultáneamente para el campus universitario de Lyngby de la DTU (Danmarks Tekniske Universitet). El objetivo del trabajo es la selección de la capacidad óptima de la bomba de calor para la producción simultánea de calefacción y de refrigeración. En el caso estudiado se utiliza el sistema de refrigeración del campus como fuente de calor para la bomba de calor. El desarrollo del modelo termodinámico de la bomba de calor se realiza en el software Engineering Equation Solver a partir de los datos de funcionamiento de los sistemas de calefacción y de refrigeración utilizados actualmente. Además, se analizan las posibilidades de otras soluciones integradas de producción así como el uso de otras fuentes de calor para la bomba de calor que puedan estar disponibles en el entorno. Todo esto se lleva a cabo, además, con un estudio económico en el que se comparan los costes asociados a la utilización de la bomba de calor, en función de la capacidad finalmente seleccionada, con los costes de la utilización de los medios convencionales de producción de calefacción y refrigeración. En este estudio económico se tiene en cuenta la variación de la demanda de calefacción y de refrigeración así como la variación de la eficiencia de la bomba de calor fuera de condiciones de diseño. Además, la demanda de calefacción y de refrigeración que no pueda ser suministrada por la bomba de calor (por no tener suficiente capacidad) se seguirá suministrando por el método actual. es_ES
dc.description.abstract [EN] This thesis investigates the possibility of installing a heat pump to produce heating and cooling simultaneously in order to supply part of the annual demand. In the development of this study, the possibility of using a single-stage cycle or a two-stage cycle is analysed, with ammonia being the refrigerant used. Both cycles have the same design input parameters. These include heating and cooling supply and return temperatures, among other technical parameters of thermodynamic cycles. . The analysis of the performance of both cycles is carried out in the EES (Engineering Equation Solver) software, where it is concluded that the two-stage cycle has better results, and will be used for the heat pump in the development of the optimization model. When the parameters to be used in the heat pump are known, an optimization model is developed using the GAMS (General Algebraic Modeling System) software, where the objective function is to obtain the minimum total annual cost of the production system. A linear model is developed, which results in the optimum capacities of the heat pump and possible storage tanks for subsequent heating and cooling supply. In addition to including the production of heating and cooling by means of the heat pump, there is the possibility of part of both productions being carried out by the production systems currently in operation on the campus. The optimization model uses the results obtained in EES as input parameters in addition to the hourly heating and cooling demands expected to be obtained during a year on campus. In addition to these values, other factors have been taken into account, such as investment and production costs. es_ES
dc.format.extent 112 es_ES
dc.language Inglés es_ES
dc.publisher Universitat Politècnica de València es_ES
dc.rights Reconocimiento - No comercial - Sin obra derivada (by-nc-nd) es_ES
dc.subject Calefacción es_ES
dc.subject Refrigeración es_ES
dc.subject Bomba de calor es_ES
dc.subject Heating es_ES
dc.subject Cooling es_ES
dc.subject Heat pump es_ES
dc.subject.classification MAQUINAS Y MOTORES TERMICOS es_ES
dc.subject.other Máster Universitario en Ingeniería Industrial (Acceso desde Grado I. de la Energía)-Màster Universitari en Enginyeria Industrial (Accés des de Grau I. de l'Energia) es_ES
dc.title Estudio de una solución integrada para calefacción y refrigeración en el campus de DTU es_ES
dc.type Tesis de máster es_ES
dc.rights.accessRights Abierto es_ES
dc.contributor.affiliation Universitat Politècnica de València. Departamento de Termodinámica Aplicada - Departament de Termodinàmica Aplicada es_ES
dc.contributor.affiliation Universitat Politècnica de València. Escuela Técnica Superior de Ingenieros Industriales - Escola Tècnica Superior d'Enginyers Industrials es_ES
dc.description.bibliographicCitation Guimarey Docampo, N. (2020). Estudio de una solución integrada para calefacción y refrigeración en el campus de DTU. Universitat Politècnica de València. http://hdl.handle.net/10251/160783 es_ES
dc.description.accrualMethod TFGM es_ES
dc.relation.pasarela TFGM\131058 es_ES


Este ítem aparece en la(s) siguiente(s) colección(ones)

Mostrar el registro sencillo del ítem