Mostrar el registro sencillo del ítem
dc.contributor.author | Monteiro, L. | es_ES |
dc.contributor.author | Pinheiro, A. | es_ES |
dc.contributor.author | Carneiro, J. | es_ES |
dc.contributor.author | Covas, D. | es_ES |
dc.coverage.spatial | east=-8.224454; north=39.39987199999999; name=Portugal | es_ES |
dc.date.accessioned | 2021-02-17T09:19:46Z | |
dc.date.available | 2021-02-17T09:19:46Z | |
dc.date.issued | 2021-01-29 | |
dc.identifier.issn | 1134-2196 | |
dc.identifier.uri | http://hdl.handle.net/10251/161630 | |
dc.description.abstract | [EN] Drinking water storage tanks allow to store water in the supply systems and help managing water demand variations. However, the tanks’ configuration and operation modes can also affect the quality of the supplied water. This paper presents a characterization of water storage tanks in Portugal, focusing on the physical and operational characteristics that affect their performance regarding mixing and water renewal. For the first time, water mixing in Portuguese storage tanks was assessed by determining the volume of renewal fractions needed to ensure the mixing of water entering each filling cycle with the existing one. The results show that mixing is guaranteed in about 74% of the circular cells and that the level variation required for this in a filling cycle is, on average, of 51%. | es_ES |
dc.description.abstract | [PT] Os reservatórios de água para consumo humano permitem garantir reservas de água nos sistemas de abastecimento e gerir variações do consumo. Contudo, a sua configuração e os modos de operação podem ter implicações na qualidade da água distribuída. Este trabalho apresenta uma caracterização dos reservatórios de água em Portugal, incidindo nas características físicas e operacionais que condicionam o seu desempenho do ponto de vista da mistura e renovação da água. Foi pela primeira vez avaliada a mistura da água nos reservatórios portugueses, pela determinação das frações de volumes de renovação necessárias para garantir a mistura da água que entra em cada ciclo de enchimento com a já existente. Os resultados mostram que a mistura é garantida em cerca de 74% das células circulares e que a variação de nível necessária para tal num ciclo de enchimento é, em média, de 51%. | es_ES |
dc.description.sponsorship | Os autores agradecem à Fundação para a Ciência e a Tecnologia pelo financiamento do projeto PTDC/ECI-EGC/32102/2017 IMIST – “Melhorar a mistura em reservatórios para o abastecimento de água mais seguro” e pela atribuição da bolsa de doutoramento PD/BD/135214/2017. É também devido um agradecimento especial a todas as entidades gestoras de serviços de águas portuguesas que colaboraram neste estudo. | es_ES |
dc.language | Portugués | es_ES |
dc.publisher | Universitat Politècnica de València | es_ES |
dc.relation.ispartof | Ingeniería del agua | es_ES |
dc.rights | Reconocimiento - No comercial - Compartir igual (by-nc-sa) | es_ES |
dc.subject | Water storage tanks | es_ES |
dc.subject | Mixing time | es_ES |
dc.subject | Turnover volume | es_ES |
dc.subject | Drinking water quality | es_ES |
dc.subject | Reservatórios | es_ES |
dc.subject | Tempo de mistura | es_ES |
dc.subject | Volume de renovação | es_ES |
dc.subject | Qualidade da água para consumo humano | es_ES |
dc.title | Caracterização dos reservatórios de água para consumo humano em Portugal | es_ES |
dc.title.alternative | Characterization of drinking water storage tanks in Portugal | es_ES |
dc.type | Artículo | es_ES |
dc.identifier.doi | 10.4995/ia.2021.13659 | |
dc.relation.projectID | info:eu-repo/grantAgreement/FCT//PD%2FBD%2F135214%2F2017/ | es_ES |
dc.relation.projectID | info:eu-repo/grantAgreement/FCT//PTDC%2FECI-EGC%2F32102%2F2017/ | es_ES |
dc.rights.accessRights | Abierto | es_ES |
dc.description.bibliographicCitation | Monteiro, L.; Pinheiro, A.; Carneiro, J.; Covas, D. (2021). Caracterização dos reservatórios de água para consumo humano em Portugal. Ingeniería del agua. 25(1):49-58. https://doi.org/10.4995/ia.2021.13659 | es_ES |
dc.description.accrualMethod | OJS | es_ES |
dc.relation.publisherversion | https://doi.org/10.4995/ia.2021.13659 | es_ES |
dc.description.upvformatpinicio | 49 | es_ES |
dc.description.upvformatpfin | 58 | es_ES |
dc.type.version | info:eu-repo/semantics/publishedVersion | es_ES |
dc.description.volume | 25 | es_ES |
dc.description.issue | 1 | es_ES |
dc.identifier.eissn | 1886-4996 | |
dc.relation.pasarela | OJS\13659 | es_ES |
dc.contributor.funder | Fundação para a Ciência e a Tecnologia, Portugal | es_ES |
dc.description.references | Chuo, P.Y., Ball, J.E., Fisher, I.H. 2003. Thermal stratification in drinking water service reservoirs. Australasian Journal of Water Resources, 6(2), 159-167. https://doi.org/10.1080/13241583.2003.11465219 | es_ES |
dc.description.references | Cherchi, C., Badruzzaman, M., Oppenheimer, J., Bros, C.M., Jacangelo, J.G. 2015. Energy and water quality management systems for water utility's operations: A review. Journal of Environmental Management, 153, 108-120. https://doi.org/10.1016/j.jenvman.2015.01.051 | es_ES |
dc.description.references | Clark, R.M., Abdesaken, F., Boulos, P.F., Mau, R.E. 1996. Mixing in Distribution System Storage Tanks: Its Effect on Water Quality. Journal of Environmental Engineering, 122(9), 814-821. https://doi.org/10.1061/(ASCE)0733-9372(1996)122:9(814) | es_ES |
dc.description.references | Grayman, W.M., Rossman, L.A., Deininger, R.A., Smith, C.D. Smith, Arnold, C.N., Smith, J.F. 2004. Mixing and ageing of water in distribution system storage facilities. Journal of the American Water Works Association, 96(9), pp. 70-80. https://doi.org/10.1002/j.1551-8833.2004.tb10704.x | es_ES |
dc.description.references | McCormick, G., Powell, R. 2003. Optimal Pump Scheduling in Water Supply Systems with Maximum Demand Charges. Journal of Water Resources Planning and Management, 129(5), 372-379. https://doi.org/10.1061/(ASCE)0733-9496(2003)129:5(372) | es_ES |
dc.description.references | Nordblom O., Bergdahl, L. 2004. Initiation of Stagnation in Drinking Water Storage Tanks. Journal of Hydraulic Engineering, 130(1), 49-57. https://doi.org/10.1061/(ASCE)0733-9429(2004)130:1(49) | es_ES |
dc.description.references | Rossman, L.A. 2000. EPANET 2 User's Manual. Cincinnati, USA: U. S. Environmental Protection Agency, 2000. | es_ES |
dc.description.references | Rossman, L.A., Grayman, W.M. 1999. Scale-Model Studies of Mixing in Drinking Water Storage Tanks. Journal of Environmental Engineering, 125(8), 755-761. https://doi.org/10.1061/(ASCE)0733-9372(1999)125:8(755) | es_ES |
dc.description.references | Tian, X., Roberts, P.J.W. 2008a. Mixing in water storage tanks. I: No buoyancy effects. Journal of Environmental Engineering, 134(12), 974-985. https://doi.org/10.1061/(ASCE)0733-9372(2008)134:12(974) | es_ES |
dc.description.references | Tian, X., Roberts, P.J.W. 2008b. Mixing in water storage tanks. II: with buoyancy effects. Journal of Environmental Engineering, 134(12), 986-995. https://doi.org/10.1061/(ASCE)0733-9372(2008)134:12(986) | es_ES |
dc.description.references | Zhang J. 2012. Passive and Active Methods for Enhancing Water Quality of Service Reservoir. Journal of Hydraulics Engineering, 139(7), 745-753. https://doi.org/10.1061/(ASCE)HY.1943-7900.0000730 | es_ES |