Estudio de la corrosión en medios cercanos a la saliva de las aleaciones base Titanio-Niobio-Plata Y Titanio-Niobio-Cobre para las aplicaciones en campo biomédico

RiuNet: Repositorio Institucional de la Universidad Politécnica de Valencia

Compartir/Enviar a

Citas

Estadísticas

  • Estadisticas de Uso

Estudio de la corrosión en medios cercanos a la saliva de las aleaciones base Titanio-Niobio-Plata Y Titanio-Niobio-Cobre para las aplicaciones en campo biomédico

Mostrar el registro sencillo del ítem

Ficheros en el ítem

dc.contributor.advisor Klyatskina Rusinovich, Elizaveta es_ES
dc.contributor.author Zagorskiy-Virot, Vadim es_ES
dc.date.accessioned 2021-03-09T12:15:02Z
dc.date.available 2021-03-09T12:15:02Z
dc.date.created 2021-01-28
dc.date.issued 2021-03-09 es_ES
dc.identifier.uri http://hdl.handle.net/10251/163498
dc.description.abstract [ES] El titanio y sus aleaciones son materiales ampliamente utilizados en el campo biomédico, especialmente en los prótesis dentbucal. De hecho, las propiedades de estas aleaciones de titanio las convierten en los mejores candidatos para las prótesis. Sin embargo, resulta que las cualidades del cobre y de la plata son indispensables en estas aleaciones porque evitan las infecciones y son buenos bactericidas. Los experimentos realizados en este trabajo ponen en práctica muestras de Ti-35Nb (titanio y 35% de niobio) a las que se añade una cierta cantidad de cobre o plata (2, 4 o 6%). Estas muestras se obtuvieron previamente mediante las técnicas de metalurgia de polvos que se describirán en este trabajo. El trabajo se centró en el estudio de la corrosión electroquímica de las muestras. Para ello, mediante un potenciostato, se midieron diferentes variables según el principio del ensamblaje de tres electrodos. A continuación, se analizaron y discutieron los resultados experimentales obtenidos para comprender su significado, su significado, pero también y sobre todo para determinar las razones de las diferencias entre la presencia de cobre y plata en una muestra de base de Ti-35Nb. es_ES
dc.description.abstract [CA] El titani i els seus aliatges són materials àmpliament utilitzats en el camp biomèdic, especialment en els pròtesis dentbucal. De fet, les propietats d'aquests aliatges de titani les converteixen en els millors candidats per a les pròtesis. No obstant això, resulta que les qualitats del coure i de la plata són indispensables en aquests aliatges perquè eviten les infeccions i són bons bactericides. Els experiments realitzats en aquest treball posen en pràctica mostres de Tu-35Nb (titani i 35% de niobi) a les quals s'afig una certa quantitat de coure o plata (2, 4 o 6%). Aquestes mostres es van obtindre prèviament mitjançant les tècniques de metal·lúrgia de pólvores que es descriuran en aquest treball. El treball es va centrar en l'estudi de la corrosió electroquímica de les mostres. Per a això, mitjançant un potenciostato, es van mesurar diferents variables segons el principi de l'assemblatge de tres elèctrodes. A continuació, es van analitzar i van discutir els resultats experimentals obtinguts per a comprendre el seu significat, el seu significat, però també i sobretot per a determinar les raons de les diferències entre la presència de coure i plata en una mostra de base de Tu-35Nb. es_ES
dc.description.abstract [EN] Titanium and its alloys are materials widely used in the biomedical field, especially when it comes to the dental prosthesis. Indeed, the properties of these titanium alloys make them the best candidates for prostheses. Nevertheless, it turns out that the qualities of copper and silver are indispensable in these alloys because they prevent infections and are good bactericides. The experiments carried out corrosion measurement in this work put into practice Ti-35Nb samples (titanium and 35% niobium) to which a certain quantity of copper or silver (2, 4 or 6%) is added. These samples were previously obtained using powder metallurgical techniques that will be described in this work. The work focused on the study of the electrochemical corrosion of the samples. For this purpose, using a potentiostat, different variables were measured on the principle of the three-electrode assembly. The experimental results obtained were then analyzed and discussed in order to understand their significance, their meaning, but also and above all to determine the reasons for the differences between the presence of copper and silver in a Ti-35Nb base sample. es_ES
dc.format.extent 58 es_ES
dc.language Inglés es_ES
dc.publisher Universitat Politècnica de València es_ES
dc.rights Reserva de todos los derechos es_ES
dc.subject Aleación de titanio es_ES
dc.subject Ti-35Nb es_ES
dc.subject Metalurgia en polvo es_ES
dc.subject Corrosión es_ES
dc.subject Potenciador es_ES
dc.subject Ensamblaje de tres electrodos es_ES
dc.subject Titanio es_ES
dc.subject Niobio es_ES
dc.subject Plata es_ES
dc.subject Cobre es_ES
dc.subject Implante es_ES
dc.subject Resistencia a la Corrosión es_ES
dc.subject Pulvimetalurgia es_ES
dc.subject Aliatge de titani es_ES
dc.subject Coure es_ES
dc.subject Metal·lúrgia en pols es_ES
dc.subject Corrosió es_ES
dc.subject Assemblatge de tres elèctrodes es_ES
dc.subject Implant es_ES
dc.subject Titanium alloy es_ES
dc.subject Niobium es_ES
dc.subject Titanium es_ES
dc.subject Silver es_ES
dc.subject Copper es_ES
dc.subject Powder metallurgy es_ES
dc.subject Corrosion es_ES
dc.subject Potentiostat es_ES
dc.subject Three-electrode assembly es_ES
dc.subject Corrosion resistance es_ES
dc.subject.classification CIENCIA DE LOS MATERIALES E INGENIERIA METALURGICA es_ES
dc.subject.other Máster Universitario en Ingeniería Industrial-Màster Universitari en Enginyeria Industrial es_ES
dc.title Estudio de la corrosión en medios cercanos a la saliva de las aleaciones base Titanio-Niobio-Plata Y Titanio-Niobio-Cobre para las aplicaciones en campo biomédico es_ES
dc.type Tesis de máster es_ES
dc.rights.accessRights Abierto es_ES
dc.contributor.affiliation Universitat Politècnica de València. Departamento de Ingeniería Mecánica y de Materiales - Departament d'Enginyeria Mecànica i de Materials es_ES
dc.contributor.affiliation Universitat Politècnica de València. Escuela Técnica Superior de Ingenieros Industriales - Escola Tècnica Superior d'Enginyers Industrials es_ES
dc.description.bibliographicCitation Zagorskiy-Virot, V. (2021). Estudio de la corrosión en medios cercanos a la saliva de las aleaciones base Titanio-Niobio-Plata Y Titanio-Niobio-Cobre para las aplicaciones en campo biomédico. Universitat Politècnica de València. http://hdl.handle.net/10251/163498 es_ES
dc.description.accrualMethod TFGM es_ES