- -

Diseño e implementación de un sistema electrónico de captación de señal de electromiografía para el estudio de la fatiga muscular en condiciones estáticas y dinámicas

RiuNet: Institutional repository of the Polithecnic University of Valencia

Share/Send to

Cited by

Statistics

  • Estadisticas de Uso

Diseño e implementación de un sistema electrónico de captación de señal de electromiografía para el estudio de la fatiga muscular en condiciones estáticas y dinámicas

Show simple item record

Files in this item

dc.contributor.advisor Coll Arnau, Salvador es_ES
dc.contributor.author Muñoz Fabra, Elena es_ES
dc.date.accessioned 2021-07-19T13:51:22Z
dc.date.available 2021-07-19T13:51:22Z
dc.date.created 2021-06-29
dc.date.issued 2021-07-19 es_ES
dc.identifier.uri http://hdl.handle.net/10251/169486
dc.description.abstract [ES] Este proyecto consiste en el diseño y desarrollo del circuito de captación procesado y adquisición de electromiograma (EMG), incluyendo los correspondientes cálculos y valoración de elección de los componentes más adecuados. Posteriormente se implementará y comprobará su correcto funcionamiento mediante el análisis de las contracciones musculares. Además, servirá para el estudio de la fatiga muscular en contracciones dinámicas y estáticas. es_ES
dc.description.abstract [CA] Aquest projecte consisteix en el disseny i desenvolupament del circuit d'un electromiograma (EMG), incloent els corresponents càlculs i valoració d'elecció dels components més adequats. Després de dissenyar aquest sistema electrònic, es realitzarà la simulació corresponent per confirmar el funcionament teòric. Posteriorment s'implementarà i comprovarà el seu correcte funcionament mitjançant l'anàlisi de les contraccions musculars. A més, servirà per a l'estudi de la fatiga muscular en contraccions dinàmiques i estàtiques. En aquest document es poden trobar diverses seccions que detallen el disseny del circuit EMG. En primer lloc, es troba la memòria, en la qual s'estableix l'objectiu, necessitats, limitacions i condicions, així com la definició dels conceptes bàsics. Addicionalment, s'expliquen les alternatives que s'han tingut en compte per al disseny i es justifiquen les solucions escollides. Finalment, s'estableix la discussió i conclusió dels resultats obtingut en els assajos. D'altra banda, es trobaran detallats els esquemes de circuit i els plànols del disseny de la placa PCB, i, a més, el pressupost del cost que representa el disseny del projecte i el plec de condicions a tenir en compte durant l'anàlisi i implementació del mateix. es_ES
dc.description.abstract [EN] This project consists of the design and development of an electromyogram (EMG) circuit, including the corresponding calculations and assessment of the choice of the most suitable components. After designing the electronic system, the corresponding simulation will be carried out to confirm the theoretical operation. Subsequently, it will be implemented and its correct operation will be checked by analysing muscle contractions. It will also be used to study muscle fatigue in dynamic and static contractions. This document contains several sections detailing the design of the EMG circuit. Firstly, there is the memory, in which the objective, needs, limitations and conditions are established, as well as the definition of the basic concepts. In addition, the alternatives that have been taken into account for the design are explained and the chosen solutions are justified. Finally, the discussion and conclusion of the results obtained in the tests is established. On the other hand, the circuit diagrams and the PCB board design plans are detailed, as well as the cost estimate for the project design and the specifications to be taken into account during the analysis and implementation of the project. es_ES
dc.format.extent 117 es_ES
dc.language Español es_ES
dc.publisher Universitat Politècnica de València es_ES
dc.rights Reserva de todos los derechos es_ES
dc.subject Electromiograma es_ES
dc.subject Electromiografía es_ES
dc.subject EMG es_ES
dc.subject Captación señal es_ES
dc.subject Procesamiento señal es_ES
dc.subject Fatiga muscular es_ES
dc.subject Contracciones musculares es_ES
dc.subject Signal uptake es_ES
dc.subject.classification TECNOLOGIA ELECTRONICA es_ES
dc.subject.other Grado en Ingeniería Electrónica Industrial y Automática-Grau en Enginyeria Electrònica Industrial i Automàtica es_ES
dc.title Diseño e implementación de un sistema electrónico de captación de señal de electromiografía para el estudio de la fatiga muscular en condiciones estáticas y dinámicas es_ES
dc.type Proyecto/Trabajo fin de carrera/grado es_ES
dc.rights.accessRights Abierto es_ES
dc.contributor.affiliation Universitat Politècnica de València. Departamento de Ingeniería Electrónica - Departament d'Enginyeria Electrònica es_ES
dc.contributor.affiliation Universitat Politècnica de València. Escuela Técnica Superior de Ingeniería del Diseño - Escola Tècnica Superior d'Enginyeria del Disseny es_ES
dc.description.bibliographicCitation Muñoz Fabra, E. (2021). Diseño e implementación de un sistema electrónico de captación de señal de electromiografía para el estudio de la fatiga muscular en condiciones estáticas y dinámicas. Universitat Politècnica de València. http://hdl.handle.net/10251/169486 es_ES
dc.description.accrualMethod TFGM es_ES
dc.relation.pasarela TFGM\140957 es_ES


This item appears in the following Collection(s)

Show simple item record