Performance Evaluation of the Dual Ring MAMMI breast PET

RiuNet: Repositorio Institucional de la Universidad Politécnica de Valencia

Compartir/Enviar a

Citas

Estadísticas

  • Estadisticas de Uso

Performance Evaluation of the Dual Ring MAMMI breast PET

Mostrar el registro sencillo del ítem

Ficheros en el ítem

dc.contributor.author Soriano, A. es_ES
dc.contributor.author Sánchez, F. es_ES
dc.contributor.author Carrilero, V. es_ES
dc.contributor.author Pardo, A. es_ES
dc.contributor.author Vidal San Sebastian, Luis Fernando es_ES
dc.contributor.author Vazquez, C. es_ES
dc.contributor.author Barbera, J. es_ES
dc.contributor.author Seimetz, Michael es_ES
dc.contributor.author Rodríguez-Álvarez, M.J. es_ES
dc.contributor.author Rigla, J. P. es_ES
dc.contributor.author Moliner, L. es_ES
dc.contributor.author Iborra, A. es_ES
dc.contributor.author Hernández, L. es_ES
dc.contributor.author González Martínez, Antonio Javier es_ES
dc.contributor.author Crespo, E. es_ES
dc.contributor.author Conde, P. es_ES
dc.contributor.author Bellido, P. es_ES
dc.contributor.author Caballero, L. es_ES
dc.contributor.author Benlloch Baviera, Jose María es_ES
dc.date.accessioned 2021-09-01T09:14:30Z
dc.date.available 2021-09-01T09:14:30Z
dc.date.issued 2013-11-02 es_ES
dc.identifier.isbn 978-1-4799-0534-8 es_ES
dc.identifier.uri http://hdl.handle.net/10251/171135
dc.description.abstract [EN] MAMMI is a dedicated breast positron emission tomograph (PET) based on monolythic LYSO crystals, with a transaxial field of view (FOV) of 170 mm. It has been upgraded by adding a second ring of detectors that extends the axial FOV from 40 mm to 94.4 mm, in order to improve its sensitivity and reduce the acquisition time. In this work we present the performance evaluation of the dual ring MAMMI breast PET and a discussion about the contribution of the addition of a second ring of detectors, the compensation of the detector blur and the increase of the scintillator thickness. Experimental measurements suggested on NEMA NU 4-2008 and NEMA NU 2-2007 have been conveniently adapted to the dimensions of the MAMMI. The addition of the second ring of detectors leads to a rise of the sensitivity from 1.8% to 3.6%. The spatial resolution at one-fourth of the axial FOV (1.5 mm axial, 1.6 mm tangential, 1.7 mm radial) is slightly better than that measured at the axial center (1.9 mm axial, 1.8 mm tangential and radial), because of the 14 mm gap in between detection rings. The results obtained after the evaluation reflect a substantial performance improvement, specially in the absolute sensitivity, because of the changes introduced in the MAMMI PET. es_ES
dc.description.sponsorship This work was supported in part bythe Spanish Plan Nacional de Investigacion Científica, Desarrollo e Innovación Tecnologica (I+D+I) under Grant No. FIS2010-21216-CO2-01 and Valencian Local Government under Grants PROMETEOII/2013/010 and ISIC 2011/013 es_ES
dc.language Inglés es_ES
dc.publisher IEEE es_ES
dc.relation.ispartof 2013 IEEE Nuclear Science Symposium and Medical Imaging Conference (2013 NSS/MIC) es_ES
dc.rights Reserva de todos los derechos es_ES
dc.subject.classification MATEMATICA APLICADA es_ES
dc.title Performance Evaluation of the Dual Ring MAMMI breast PET es_ES
dc.type Comunicación en congreso es_ES
dc.type Capítulo de libro es_ES
dc.identifier.doi 10.1109/NSSMIC.2013.6829103 es_ES
dc.relation.projectID info:eu-repo/grantAgreement/GVA//ISIC%2F2011%2F013/ es_ES
dc.relation.projectID info:eu-repo/grantAgreement/MICINN//FIS2010-21216-C02-01/ES/DESARROLLO DEL DETECTOR PET%2FRM PARA DIAGNOSTICO DE ENFERMEDADES NEURODEGENERATIVAS./ es_ES
dc.relation.projectID info:eu-repo/grantAgreement/GVA//PROMETEOII%2F2013%2F010/ es_ES
dc.rights.accessRights Abierto es_ES
dc.contributor.affiliation Universitat Politècnica de València. Departamento de Matemática Aplicada - Departament de Matemàtica Aplicada es_ES
dc.contributor.affiliation Universitat Politècnica de València. Instituto de Instrumentación para Imagen Molecular - Institut d'Instrumentació per a Imatge Molecular es_ES
dc.description.bibliographicCitation Soriano, A.; Sánchez, F.; Carrilero, V.; Pardo, A.; Vidal San Sebastian, LF.; Vazquez, C.; Barbera, J.... (2013). Performance Evaluation of the Dual Ring MAMMI breast PET. IEEE. 1-4. https://doi.org/10.1109/NSSMIC.2013.6829103 es_ES
dc.description.accrualMethod S es_ES
dc.relation.conferencename IEEE Nuclear Science Symposium and Medical Imaging Conference, and Room-Temperature Semiconductor X-Ray and Gamma-Ray Detectors Workshop (2013 IEEE NSS/MIC/RTSD) es_ES
dc.relation.conferencedate Octubre 27-Noviembre 02,2013 es_ES
dc.relation.conferenceplace Seoul, Korea es_ES
dc.relation.publisherversion https://doi.org/10.1109/NSSMIC.2013.6829103 es_ES
dc.description.upvformatpinicio 1 es_ES
dc.description.upvformatpfin 4 es_ES
dc.type.version info:eu-repo/semantics/publishedVersion es_ES
dc.relation.pasarela S\260609 es_ES
dc.contributor.funder Generalitat Valenciana es_ES
dc.contributor.funder Ministerio de Ciencia e Innovación es_ES


Este ítem aparece en la(s) siguiente(s) colección(ones)