Diseño, integración y validación de un sistema de registro simultáneo de EEG y sEMG deglutorio

RiuNet: Repositorio Institucional de la Universidad Politécnica de Valencia

Compartir/Enviar a

Citas

Estadísticas

  • Estadisticas de Uso

Diseño, integración y validación de un sistema de registro simultáneo de EEG y sEMG deglutorio

Mostrar el registro sencillo del ítem

Ficheros en el ítem

dc.contributor.advisor Garcia Casado, Francisco Javier es_ES
dc.contributor.advisor Ye Lin, Yiyao es_ES
dc.contributor.author Moya Rabadán, Francisco es_ES
dc.date.accessioned 2021-09-23T15:06:45Z
dc.date.available 2021-09-23T15:06:45Z
dc.date.created 2021-09-07
dc.date.issued 2021-09-23 es_ES
dc.identifier.uri http://hdl.handle.net/10251/173186
dc.description.abstract [ES] La disfagia es un problema que afecta a 1 de cada 17 personas en el mundo. Esta patología puede presentarse de numerosas formas y puede tener origen tanto debido a un mal funcionamiento de los músculos deglutorios como a un mal funcionamiento del sistema nervioso, por lo que el análisis de señales de electroencefalograma (EEG) y electromiograma en superficie (sEMG) nos puede proporcionar información sobre la presencia de esta patología o riesgo de padecerla en un futuro a partir de ciertos parámetros, así como la posibilidad de diseñar futuros tratamientos y valorar sus efectos. Existen bastantes estudios de señales de sEMG deglutorio, muy pocos de EEG en deglución, y en nuestro conocimiento ninguno que haya valorado las señales conjuntamente. El objetivo principal de este TFG es diseñar un sistema de registro simultáneo de señales de EEG y sEMG de músculos deglutorios, así como verificar su correcto funcionamiento. Esto es necesario para lograr los objetivos de un proyecto más a largo plazo en el que se pretende caracterizar estas señales y sus posibles relaciones tanto en sujetos sanos como patológicos, establecer rangos y patrones de normalidad y posibles alteraciones por distintas patologías, efectos de posibles tratamientos, etc. Mediante el sistema a desarrollar se deben registrar las señales de EEG y sEMG asociadas a la actividad deglutoria de distintos tipos de bolos (saliva, agua, yogurt) con `marcas¿ de sincronismo ante distintos eventos como la preparación de la deglución y el inicio de los procesos mentales y musculares que la desencadenan. Para el diseño e integración del sistema de registro se deberán plantear abordar, de acuerdo a las especificaciones/requerimientos de esta aplicación específica: la selección de número, tipo y localización de electrodos; selección, conexión y configuración del hardware de acondicionamiento y adquisición de señal; selección, configuración y programación parcial del software de adquisición de señal con marcadores de eventos; etc¿ Para la validación del sistema desarrollado se definirá un protocolo detallado de registro que se realizará sobre 20-25 voluntarios sanos, y se realizará una visualización y análisis preliminar de las señales tanto de EEG como de sEMG verificando si su morfología y características básicas relativas a amplitud, contenido espectral¿ son acordes a la literatura. es_ES
dc.description.abstract [EN] Dysphagia is the inability of people to swallow properly. It affects 1 in 17 people and greatly shortens the life expectancy of those who suffer from it, as well as greatly increasing morbidity. It mainly affects the older population and those who have had a neurological problem such as a stroke. It is a very complex disease that can have many different origins: neurological, muscular, immunological, congenital… The 2 main causes of dysphagia are of neurological and muscular origin. This is the reason why it is necessary to develop a system for simultaneous recording of an EEG signal and swallowing sEMG. In this work we will develop not only the complete system but also the protocol to carry out the signal recording. On the design side, all the necessary points will be covered. Explaining from the amplifier used and its performance, through the different types of electrodes used, to the explanation of the signal acquisition and analysis software. Likewise, a protocol has been developped when carrying out the recording, in which there are 2 different types of recordings: a recording when the patient is relaxed and the base line is recorded, and 20 recordings of 3 different types of boluses (60 trials in total) to analyse the reaction to foods with different types of textures. Finally, the signals obtained using EEGLab will be analysed to check that both the system designed and the protocol are correct and detect both EEG and sEMG signals in an adequate way by means of several analyses carried out on each type of signal. es_ES
dc.format.extent 80 es_ES
dc.language Español es_ES
dc.publisher Universitat Politècnica de València es_ES
dc.rights Reconocimiento - No comercial - Sin obra derivada (by-nc-nd) es_ES
dc.subject Deglución es_ES
dc.subject Señales biomédicas es_ES
dc.subject Instrumentación biomédica es_ES
dc.subject Sistema de registro es_ES
dc.subject.classification TECNOLOGIA ELECTRONICA es_ES
dc.subject.other Grado en Ingeniería Biomédica-Grau en Enginyeria Biomèdica es_ES
dc.title Diseño, integración y validación de un sistema de registro simultáneo de EEG y sEMG deglutorio es_ES
dc.type Proyecto/Trabajo fin de carrera/grado es_ES
dc.rights.accessRights Abierto es_ES
dc.contributor.affiliation Universitat Politècnica de València. Departamento de Ingeniería Electrónica - Departament d'Enginyeria Electrònica es_ES
dc.contributor.affiliation Universitat Politècnica de València. Escuela Técnica Superior de Ingenieros Industriales - Escola Tècnica Superior d'Enginyers Industrials es_ES
dc.description.bibliographicCitation Moya Rabadán, F. (2021). Diseño, integración y validación de un sistema de registro simultáneo de EEG y sEMG deglutorio. Universitat Politècnica de València. http://hdl.handle.net/10251/173186 es_ES
dc.description.accrualMethod TFGM es_ES
dc.relation.pasarela TFGM\143371 es_ES


Este ítem aparece en la(s) siguiente(s) colección(ones)

Mostrar el registro sencillo del ítem