- -

Desarrollo y análisis de validez de un nuevo sistema experimental de microscopía fotoacústica de resolución óptica

RiuNet: Repositorio Institucional de la Universidad Politécnica de Valencia

Compartir/Enviar a

Citas

Estadísticas

  • Estadisticas de Uso

Desarrollo y análisis de validez de un nuevo sistema experimental de microscopía fotoacústica de resolución óptica

Mostrar el registro sencillo del ítem

Ficheros en el ítem

dc.contributor.advisor Camarena Femenia, Francisco es_ES
dc.contributor.advisor Cebrecos Ruiz, Alejandro es_ES
dc.contributor.advisor García Garrigós, Juan José es_ES
dc.contributor.author Navarro Calvo, Javier Ángel es_ES
dc.date.accessioned 2021-10-04T16:40:35Z
dc.date.available 2021-10-04T16:40:35Z
dc.date.created 2021-09-14
dc.date.issued 2021-10-04 es_ES
dc.identifier.uri http://hdl.handle.net/10251/173755
dc.description.abstract [ES] La necesidad actual de seguir creando y mejorando técnicas de imagen para diagnóstico y pre- vención de enfermedades es el motor de miles de investigaciones en el sector de la biomedicina en todo el mundo. Este TFG se enmarca en la modalidad de imagen de microscopía fotoacústica de resolución óptica (OR-PAM). Esta reciente técnica de imagen, cuyo auge ha tenido lugar durante los últimos 15 años, permite obtener imagenes microscópicas de alta resolución tanto morfológicas como funcionales y cinéticas. Esto es debido a que los agentes de contraste utiliza- dos pueden ser tanto endógenos (hemoglobina, melanina, etc.) como exógenos (nanopartículas o tintes), resultando ser extremadamente útil y eficaz a la hora de detectar cánceres de piel y de mama, así como patologías vasculares en tejidos biológicos, dentro de un largo etcétera de potenciales aplicaciones de esta técnica de imagen. El objetivo de este TFG es el de desarrollar, caracterizar y analizar la validez de un nuevo sistema OR-PAM de bajo coste, utilizando fuentes de luz láser de menor calidad para abaratar su coste total. Para ello, se ha utilizado un diodo láser pulsado (PLD) como fuente de excitación fotoacústica, el cual se ha acoplado a una fibra óptica de núcleo cuadrado, con el objetivo de homogeneizar el patrón no uniforme que ofrece el PLD para conseguir una nueva fuente de luz cuadrada y uniforme. Utilizando una sonda de ultrasonidos phased-array de 128 canales, se han realizado varios tests de adquisición de imágenes fotoacústicas de un target de resolución de la USAF. La validación del sistema montado se ha realizado mediante mediciones de la energía de pulso y la sección transversal del haz en los puntos clave del sistema óptico, así como con la posterior implementación del algoritmo de reconstrucción de imagen de retardo y suma (DAS). También se han obtenido otros parámetros característicos como la resolución lateral, la relación señal a ruido (SNR) y el contraste de la imagen. Este proyecto ha incluido tanto el estudio previo, como el montaje y caracterización del sistema óptico, además del desarollo del algoritmo de reconstrucción de imagen DAS y el análisis de las imágenes fotoacústicas obtenidas. es_ES
dc.description.abstract [EN] The current need to continue creating and improving imaging techniques for diagnosis and dis- ease prevention is the driving force behind thousands of research projects in the biomedical sector worldwide. This TFG is within the frame of optical-resolution photoacoustic microscopy imaging (OR-PAM). This recent imaging technique, which has been gaining interest over the last 15 years, allows to obtain high-resolution microscopic images of morphological, as well as functional and kinetical information. This is due to the fact that the used contrast agents can be both endogenous (haemoglobin, melanin, etc.) and exogenous (nanoparticles or dyes), which results extremely useful and effective when detecting skin and breast cancers, as well as vascu- lar pathologies in biological tissues, over a long list of future potential applications of this new imaging modality. The main objetive of this work is to develop, characterise and analyse the validity of a new low-cost OR-PAM system, using lower quality laser beam sources to reduce its total cost. To this purpose, a pulsed laser diode (PLD) was used as photoacoustic excitation source, which was coupled to a squared-core optical fiber, with the aim of homogenising the non-uniform light pattern offered by the PLD into a square and uniform laser spot. Using a 128-element phased- array ultrasound probe, several tests have been carried out to acquire photoacoustic images of a USAF resolution target. The validation of the assembled system was carried out by laser pulse energy and beam cross-section optical measurements at several key points of the system optics, as well as by the subsequent implementation of the delay-and-sum (DAS) image reconstruction algorithm. Also other PA imaging characteristic parameters such as the lateral resolution, the signal-to-noise ratio (SNR) and the image contrast were obtained. This work has included the preliminary study, the assembly and characterisation of the optical system, the development of the DAS image reconstruction algorithm, as well as the analysis of the acquired photoacoustic images. es_ES
dc.format.extent 70 es_ES
dc.language Español es_ES
dc.publisher Universitat Politècnica de València es_ES
dc.rights Reserva de todos los derechos es_ES
dc.subject Microscopía fotoacústica es_ES
dc.subject Diodo láser es_ES
dc.subject Transductor ultrasonidos phased array es_ES
dc.subject Fibra óptica. es_ES
dc.subject Photoacoustic Microscopy es_ES
dc.subject Laser diode es_ES
dc.subject Phased array ultrasound transducer es_ES
dc.subject Optical fiber. es_ES
dc.subject.classification FISICA APLICADA es_ES
dc.subject.other Grado en Ingeniería Biomédica-Grau en Enginyeria Biomèdica es_ES
dc.title Desarrollo y análisis de validez de un nuevo sistema experimental de microscopía fotoacústica de resolución óptica es_ES
dc.type Proyecto/Trabajo fin de carrera/grado es_ES
dc.rights.accessRights Cerrado es_ES
dc.contributor.affiliation Universitat Politècnica de València. Departamento de Física Aplicada - Departament de Física Aplicada es_ES
dc.contributor.affiliation Universitat Politècnica de València. Escuela Técnica Superior de Ingenieros Industriales - Escola Tècnica Superior d'Enginyers Industrials es_ES
dc.description.bibliographicCitation Navarro Calvo, JÁ. (2021). Desarrollo y análisis de validez de un nuevo sistema experimental de microscopía fotoacústica de resolución óptica. Universitat Politècnica de València. http://hdl.handle.net/10251/173755 es_ES
dc.description.accrualMethod TFGM es_ES
dc.relation.pasarela TFGM\141122 es_ES


Este ítem aparece en la(s) siguiente(s) colección(ones)

Mostrar el registro sencillo del ítem