Estudio y optimización energética de una estación de bombeo de agua potable en el depósito del Barrio de La Coma, Paterna (Valencia)

RiuNet: Repositorio Institucional de la Universidad Politécnica de Valencia

Compartir/Enviar a

Citas

Estadísticas

  • Estadisticas de Uso

Estudio y optimización energética de una estación de bombeo de agua potable en el depósito del Barrio de La Coma, Paterna (Valencia)

Mostrar el registro sencillo del ítem

Ficheros en el ítem

dc.contributor.advisor Bayón Barrachina, Arnau es_ES
dc.contributor.author Santamaría Chuliá, Álvaro Ramón es_ES
dc.coverage.spatial east=-0.4313771396158228; north=39.520224083142125; name=Carrer el Puig, 37, 46980 Paterna, Valencia, Espanya es_ES
dc.date.accessioned 2021-10-08T14:00:29Z
dc.date.available 2021-10-08T14:00:29Z
dc.date.created 2021-09-09
dc.date.issued 2021-10-08 es_ES
dc.identifier.uri http://hdl.handle.net/10251/174275
dc.description.abstract [ES] La disminución de los recursos hídricos, así como la necesidad del ahorro energético y reducción de emisiones contaminantes motivan la optimización de la producción, distribución y consumo de agua potable. El presente Trabajo de Fin de Grado desarrollado en prácticas de empresa en Aguas de Valencia, contempla un estudio de optimización energética de la estación de bombeo de agua potable ubicada en el depósito del barrio de la Coma, situado en Paterna (Valencia). Concretamente, la instalación se compone de un depósito de 2 vasos de 2500 m3 cada uno, una estación de bombeo compuesta por 3 grupos de bombeo que permiten el suministro de agua potable a varios puntos y una turbina para autoconsumo. Además de esto, la instalación cuenta con todo el sistema eléctrico y de telemando, empleado para la monitorización de las distintas variables de control y calidad de la instalación. En este documento se realiza un estudio detallado de la instalación y análisis de su funcionamiento. El estudio consiste en la recopilación de todos los datos necesarios, así como su análisis mediante herramientas como Microsoft Excel. Esto permite identificar ineficiencias existentes en la instalación, las cuales motivan la implantación de diversas medidas de mejora energética, todo ello enfocado además desde una perspectiva económica ofreciendo alternativas que resulten viables para el organismo gestor de la instalación. es_ES
dc.description.abstract [EN] The reduction of hydraulic resources, as well as the need to save energy and reduce pollutant emissions, motivate the optimization of the production, distribution, and consumption of drinking water. This Final Degree Project develops a study of energy optimization of the drinking water pumping station located in the reservoir of La Coma neighborhood, located in Paterna (Valencia). Specifically, the installation consists of a tank with 2 vessels of 2500 m3 each, a pumping station composed of 3 pumping groups that allow the supply of drinking water to several points and a turbine for self-consumption. In addition to this, the installation has the entire electrical and remote-control system, used to monitor the different control and quality variables of the installation. In this document, a detailed study of the installation and analysis of its operation has been carried out. The study consisted of the collection of all the necessary data, as well as their analysis with tools like Microsoft Excel. This has made it possible to identify existing inefficiencies in the installation, which have led to the implementation of various energy improvement measures. All of this has also been approached from an economic perspective, offering alternatives that are viable for the organization managing the facility. es_ES
dc.format.extent 96 es_ES
dc.language Español es_ES
dc.publisher Universitat Politècnica de València es_ES
dc.rights Reserva de todos los derechos es_ES
dc.subject Bomba es_ES
dc.subject Turbina es_ES
dc.subject Instalación de bombeo es_ES
dc.subject Auditoría es_ES
dc.subject Eficiencia energética es_ES
dc.subject Drinking water es_ES
dc.subject Energy optimization es_ES
dc.subject Water pumping station es_ES
dc.subject Tanks es_ES
dc.subject Turbine. es_ES
dc.subject.classification INGENIERIA HIDRAULICA es_ES
dc.subject.other Grado en Ingeniería en Tecnologías Industriales-Grau en Enginyeria en Tecnologies Industrials es_ES
dc.title Estudio y optimización energética de una estación de bombeo de agua potable en el depósito del Barrio de La Coma, Paterna (Valencia) es_ES
dc.type Proyecto/Trabajo fin de carrera/grado es_ES
dc.rights.accessRights Cerrado es_ES
dc.contributor.affiliation Universitat Politècnica de València. Departamento de Ingeniería Hidráulica y Medio Ambiente - Departament d'Enginyeria Hidràulica i Medi Ambient es_ES
dc.contributor.affiliation Universitat Politècnica de València. Escuela Técnica Superior de Ingenieros Industriales - Escola Tècnica Superior d'Enginyers Industrials es_ES
dc.description.bibliographicCitation Santamaría Chuliá, ÁR. (2021). Estudio y optimización energética de una estación de bombeo de agua potable en el depósito del Barrio de La Coma, Paterna (Valencia). Universitat Politècnica de València. http://hdl.handle.net/10251/174275 es_ES
dc.description.accrualMethod TFGM es_ES
dc.relation.pasarela TFGM\142459 es_ES


Este ítem aparece en la(s) siguiente(s) colección(ones)

Mostrar el registro sencillo del ítem