Mostrar el registro sencillo del ítem
dc.contributor.advisor | Bayón Barrachina, Arnau | es_ES |
dc.contributor.author | Santamaría Chuliá, Álvaro Ramón | es_ES |
dc.coverage.spatial | east=-0.4313771396158228; north=39.520224083142125; name=Carrer el Puig, 37, 46980 Paterna, Valencia, Espanya | es_ES |
dc.date.accessioned | 2021-10-08T14:00:29Z | |
dc.date.available | 2021-10-08T14:00:29Z | |
dc.date.created | 2021-09-09 | |
dc.date.issued | 2021-10-08 | es_ES |
dc.identifier.uri | http://hdl.handle.net/10251/174275 | |
dc.description.abstract | [ES] La disminución de los recursos hídricos, así como la necesidad del ahorro energético y reducción de emisiones contaminantes motivan la optimización de la producción, distribución y consumo de agua potable. El presente Trabajo de Fin de Grado desarrollado en prácticas de empresa en Aguas de Valencia, contempla un estudio de optimización energética de la estación de bombeo de agua potable ubicada en el depósito del barrio de la Coma, situado en Paterna (Valencia). Concretamente, la instalación se compone de un depósito de 2 vasos de 2500 m3 cada uno, una estación de bombeo compuesta por 3 grupos de bombeo que permiten el suministro de agua potable a varios puntos y una turbina para autoconsumo. Además de esto, la instalación cuenta con todo el sistema eléctrico y de telemando, empleado para la monitorización de las distintas variables de control y calidad de la instalación. En este documento se realiza un estudio detallado de la instalación y análisis de su funcionamiento. El estudio consiste en la recopilación de todos los datos necesarios, así como su análisis mediante herramientas como Microsoft Excel. Esto permite identificar ineficiencias existentes en la instalación, las cuales motivan la implantación de diversas medidas de mejora energética, todo ello enfocado además desde una perspectiva económica ofreciendo alternativas que resulten viables para el organismo gestor de la instalación. | es_ES |
dc.description.abstract | [EN] The reduction of hydraulic resources, as well as the need to save energy and reduce pollutant emissions, motivate the optimization of the production, distribution, and consumption of drinking water. This Final Degree Project develops a study of energy optimization of the drinking water pumping station located in the reservoir of La Coma neighborhood, located in Paterna (Valencia). Specifically, the installation consists of a tank with 2 vessels of 2500 m3 each, a pumping station composed of 3 pumping groups that allow the supply of drinking water to several points and a turbine for self-consumption. In addition to this, the installation has the entire electrical and remote-control system, used to monitor the different control and quality variables of the installation. In this document, a detailed study of the installation and analysis of its operation has been carried out. The study consisted of the collection of all the necessary data, as well as their analysis with tools like Microsoft Excel. This has made it possible to identify existing inefficiencies in the installation, which have led to the implementation of various energy improvement measures. All of this has also been approached from an economic perspective, offering alternatives that are viable for the organization managing the facility. | es_ES |
dc.format.extent | 96 | es_ES |
dc.language | Español | es_ES |
dc.publisher | Universitat Politècnica de València | es_ES |
dc.rights | Reserva de todos los derechos | es_ES |
dc.subject | Bomba | es_ES |
dc.subject | Turbina | es_ES |
dc.subject | Instalación de bombeo | es_ES |
dc.subject | Auditoría | es_ES |
dc.subject | Eficiencia energética | es_ES |
dc.subject | Drinking water | es_ES |
dc.subject | Energy optimization | es_ES |
dc.subject | Water pumping station | es_ES |
dc.subject | Tanks | es_ES |
dc.subject | Turbine. | es_ES |
dc.subject.classification | INGENIERIA HIDRAULICA | es_ES |
dc.subject.other | Grado en Ingeniería en Tecnologías Industriales-Grau en Enginyeria en Tecnologies Industrials | es_ES |
dc.title | Estudio y optimización energética de una estación de bombeo de agua potable en el depósito del Barrio de La Coma, Paterna (Valencia) | es_ES |
dc.type | Proyecto/Trabajo fin de carrera/grado | es_ES |
dc.rights.accessRights | Cerrado | es_ES |
dc.contributor.affiliation | Universitat Politècnica de València. Departamento de Ingeniería Hidráulica y Medio Ambiente - Departament d'Enginyeria Hidràulica i Medi Ambient | es_ES |
dc.contributor.affiliation | Universitat Politècnica de València. Escuela Técnica Superior de Ingenieros Industriales - Escola Tècnica Superior d'Enginyers Industrials | es_ES |
dc.description.bibliographicCitation | Santamaría Chuliá, ÁR. (2021). Estudio y optimización energética de una estación de bombeo de agua potable en el depósito del Barrio de La Coma, Paterna (Valencia). Universitat Politècnica de València. http://hdl.handle.net/10251/174275 | es_ES |
dc.description.accrualMethod | TFGM | es_ES |
dc.relation.pasarela | TFGM\142459 | es_ES |