- -

Estudio de dosimetría en tratamiento de cáncer de hígado empleando microesferas de Y-90 mediante simulaciones con Monte Carlo

RiuNet: Repositorio Institucional de la Universidad Politécnica de Valencia

Compartir/Enviar a

Citas

Estadísticas

  • Estadisticas de Uso

Estudio de dosimetría en tratamiento de cáncer de hígado empleando microesferas de Y-90 mediante simulaciones con Monte Carlo

Mostrar el registro sencillo del ítem

Ficheros en el ítem

dc.contributor.advisor Juste Vidal, Belen Jeanne es_ES
dc.contributor.advisor Miró Herrero, Rafael es_ES
dc.contributor.author Larena González, Claudia es_ES
dc.coverage.spatial east=-0.34497922105709566; north=39.48147566604911; name=La Carrasca, València, Espanya es_ES
dc.date.accessioned 2021-10-26T14:38:34Z
dc.date.available 2021-10-26T14:38:34Z
dc.date.created 2021-09-28
dc.date.issued 2021-10-26 es_ES
dc.identifier.uri http://hdl.handle.net/10251/175615
dc.description.abstract [ES] El objetivo del presente Trabajo Final de Máster (TFM) es realizar un estudio dosimétrico de un tratamiento de braquiterapia hepática que emplea microesferas de Y-90 mediante simulación empleando el método de Monte Carlo. Si bien, un tratamiento de braquiterapia consiste en la introducción de la fuente en el interior del tumor, en concreto, para los carcinomas hepáticos, se emplea la radioembolización que consiste en la introducción de dichas semillas mediante la arteria hepática. Por ello, es importante conocer la dosis exacta que recibe el hígado, así como otros órganos colindantes que se pueden ver vascularmente afectados como es el caso del pulmón o el tracto gastrointestinal. Para ello, se emplea el modelo anatómico 3D distribuido recientemente por la Comisión Internacional de Protección Radiológica (ICRP) conocido como Fantoma Computacional de Referencia de Tipo de Malla (MRCP). Una vez segmentado el maniquí, se simula el tratamiento con el método de Monte Carlo, haciendo uso del código MCNP, introduciendo una fuente de Y-90 en el interior del hígado, así como todas las especificaciones de la física del transporte de fotones y electrones necesaria para la simulación. Como resultado, se obtiene la dosis que recibe el tumor del hígado, así como cada órgano colindante en un tratamiento de estas características. Se comprueba, además, que las dosis recibidas son seguras y se ajustan con los resultados empíricos. Con ello se demuestra que este método de simulación puede resultar adecuado para planificar tratamientos de braquiterapia obteniendo resultados fiables en un tiempo de computación asequible. es_ES
dc.description.abstract [EN] The objective of this Master's Final Project (TFM) is to carry out a dosimetric study of a liver brachytherapy treatment that uses Y-90 microspheres by simulation using the Monte Carlo method. Although, a brachytherapy treatment consists of the introduction of the source into the tumor, in particular, for liver carcinomas, radioembolization is used, which consists of the introduction of these seeds through the hepatic artery. Therefore, it is important to know the exact dose received by the liver, as well as other adjoining organs that may be vascularly affected as is the case of the lung or the gastrointestinal tract. To do this, the 3D anatomical model recently distributed by the International Commission on Radiological Protection (ICRP) known as Mesh Type Reference Computational Fantoma (MRCP) is used. Once the mannequin is segmented, the treatment is simulated with the Monte Carlo method, making use of the MCNP code, introducing a Y-90 source inside the liver, as well as all the specifications of the physics of photon and electron transport necessary for the simulation. As a result, the dose received by the liver tumor is obtained, as well as each adjoining organ in a treatment of these characteristics. It is also verified that the doses received are safe and are adjusted with the empirical results. This demonstrates that this simulation method can be suitable for planning brachytherapy treatments obtaining reliable results in an affordable computer time. es_ES
dc.format.extent 171 es_ES
dc.language Español es_ES
dc.publisher Universitat Politècnica de València es_ES
dc.rights Reserva de todos los derechos es_ES
dc.subject Dosimetría es_ES
dc.subject Simulación es_ES
dc.subject Método Monte Carlo es_ES
dc.subject Radioembolización es_ES
dc.subject Microesferas es_ES
dc.subject Y-90 es_ES
dc.subject MRCP es_ES
dc.subject Braquiterapia es_ES
dc.subject Hígado. es_ES
dc.subject Dosimetry es_ES
dc.subject Simulation es_ES
dc.subject Monte Carlo method es_ES
dc.subject Radioembolization es_ES
dc.subject Microspheres es_ES
dc.subject Brachytherapy es_ES
dc.subject Liver. es_ES
dc.subject.classification INGENIERIA NUCLEAR es_ES
dc.subject.other Máster Universitario en Ingeniería Química-Màster Universitari en Enginyeria Química es_ES
dc.title Estudio de dosimetría en tratamiento de cáncer de hígado empleando microesferas de Y-90 mediante simulaciones con Monte Carlo es_ES
dc.type Tesis de máster es_ES
dc.rights.accessRights Cerrado es_ES
dc.contributor.affiliation Universitat Politècnica de València. Departamento de Ingeniería Química y Nuclear - Departament d'Enginyeria Química i Nuclear es_ES
dc.contributor.affiliation Universitat Politècnica de València. Escuela Técnica Superior de Ingenieros Industriales - Escola Tècnica Superior d'Enginyers Industrials es_ES
dc.description.bibliographicCitation Larena González, C. (2021). Estudio de dosimetría en tratamiento de cáncer de hígado empleando microesferas de Y-90 mediante simulaciones con Monte Carlo. Universitat Politècnica de València. http://hdl.handle.net/10251/175615 es_ES
dc.description.accrualMethod TFGM es_ES
dc.relation.pasarela TFGM\146164 es_ES


Este ítem aparece en la(s) siguiente(s) colección(ones)

Mostrar el registro sencillo del ítem