Evaluación comparativa mediante ensayos biomecánicos de anillos moldeables de ostomía

RiuNet: Repositorio Institucional de la Universidad Politécnica de Valencia

Compartir/Enviar a

Citas

Estadísticas

  • Estadisticas de Uso

Evaluación comparativa mediante ensayos biomecánicos de anillos moldeables de ostomía

Mostrar el registro sencillo del ítem

Ficheros en el ítem

dc.contributor.author Gómez Pérez, Amelia Lucia es_ES
dc.contributor.author Panadero Morales, Raúl es_ES
dc.contributor.author García-Torres, Fernando es_ES
dc.contributor.author Solera Navarro, Mª Jesús es_ES
dc.contributor.author PERIS SERRA, JOSE LUIS es_ES
dc.contributor.author García Blázquez, Eduardo es_ES
dc.contributor.author ATIENZA VICENTE, CARLOS MANUEL es_ES
dc.date.accessioned 2021-11-05T12:36:55Z
dc.date.available 2021-11-05T12:36:55Z
dc.date.issued 2020-12 es_ES
dc.identifier.issn 1138-7262 es_ES
dc.identifier.uri http://hdl.handle.net/10251/176111
dc.description.abstract [ES] Objetivo: determinar la resistencia a la degradación en solución salina de diversos anillos moldeables para ostomía, así como comprobar si existen diferencias estadísticamente significativas entre la resistencia a la degradación de los anillos moldeables de Coloplast (Col-2 y Col-4,2) con respecto a dos anillos moldeables comerciales de otros fabricantes (Fab1 y Fab2). Métodos: el material objeto de ensayo consiste en cuatro modelos de anillos moldeables: Col-2 de 2 mm de espesor, Col-4,2 de 4,2 mm de espesor, Fab1 y Fab2 de espesor 4 mm. El tamaño de la muestra de ensayo fue de 10 unidades por tipo de sistema. Los ensayos fueron realizados en el laboratorio de ensayos del Instituto de Biomecánica de Valencia, utilizando una máquina universal de ensayos INSTRON8874/511, con unas condiciones ambientales de temperatura (23 ºC) y de humedad (56%). Resultados: el análisis estadístico de los resultados revela diferencias estadísticamente significativas (p< 0,001) entre las muestras pertenecientes a Coloplast (Col-2= 1,84 N y Col-4,2 = 1,97 N) con las muestras de los fabricantes 1 y 2 (Fab1= 0,90 N y Fab2= 0,92 N). No se observan diferencias estadísticamente significativas entre las dos muestras de Coloplast (p= 0,706) ni entre las dos muestras de los otros dos fabricantes (p= 0,917). Conclusión: las dos muestras de Coloplast presentan valores de fuerza de penetración significativamente mayores (dos veces superiores) que las muestras de los otros dos fabricantes y, por tanto, una mayor resistencia a la degradación a las seis horas de estar sumergida en un suero salino. Sin embargo, no se observan diferencias estadísticamente significativas en la resistencia a la degradación entre las dos muestras de Coloplast a pesar de ser anillos de diferente grosor. Este efecto se debe a que las mediciones se han realizado con penetraciones de 1 mm. es_ES
dc.description.abstract [EN] Objective: to determine the resistance to degradation in saline solution for different moldable rings for ostomy, as well to confirm if there are any statistically differences between the resistance to degradation in Coloplast moldable rings (Col-2 and Col-4.2) vs. two moldable rings marketed by other manufacturers (Fab1 and Fab2). Methods: the material object of the trial consisted in four models of moldable rings: Col-2 with 2 mm thickness, Col-4.2 with 4.2 mm thickness, and Fab1 & Fab2 4 mm thickness. The trial sample size was 10 units per type of system. The trials were conducted at the testing laboratory of the Biomechanical Institute, Valencia, using a universal testing machine INSTRON8874/511, under environmental conditions of temperature (23 ºC) and humidity (56%). Results: the statistical analysis of results revealed statistically significant differences (p< 0.001) between the Coloplast samples (Col-2= 1.84 N and Col-4.2 = 1.97 N) and the samples from manufacturers 1 and 2 (Fab1= 0.90 N and Fab2= 0.92 N). No statistically significant differences were observed between the two Coloplast samples (p= 0.706) or between the two samples from the other two manufacturers (p= 0.917). Conclusion: the two Coloplast samples presented significantly higher penetration strength values (twice higher) than the samples from the other two manufacturers; and therefore, higher resistance to degradation at six hours of being immersed in saline. However, no statistically significant differences were observed in terms of resistance to degradation between both Coloplast samples, regardless of the different thickness of the rings. This effect was due to measurements being conducted with 1mm penetrations. es_ES
dc.language Español es_ES
dc.publisher DAE.Difusion Avances Enfermeria es_ES
dc.relation.ispartof Metas de Enfermeria es_ES
dc.rights Reserva de todos los derechos es_ES
dc.subject Estoma es_ES
dc.subject Colostomía es_ES
dc.subject Fugas es_ES
dc.subject Piel periestomal es_ES
dc.subject Modelos de anillos moldeables es_ES
dc.subject Resistencia a la degradación es_ES
dc.subject Stoma es_ES
dc.subject Colostomy es_ES
dc.subject Leaks es_ES
dc.subject Peristomal skin es_ES
dc.subject Moldable ring models es_ES
dc.subject Resistance to degradation es_ES
dc.subject.classification INGENIERIA MECANICA es_ES
dc.title Evaluación comparativa mediante ensayos biomecánicos de anillos moldeables de ostomía es_ES
dc.title.alternative Comparative assessment through biomechanical trials between moldable rings for ostomy es_ES
dc.type Artículo es_ES
dc.identifier.doi 10.35667/MetasEnf.2020.23.1003081683 es_ES
dc.rights.accessRights Cerrado es_ES
dc.contributor.affiliation Universitat Politècnica de València. Departamento de Ingeniería Mecánica y de Materiales - Departament d'Enginyeria Mecànica i de Materials es_ES
dc.description.bibliographicCitation Gómez Pérez, AL.; Panadero Morales, R.; García-Torres, F.; Solera Navarro, MJ.; Peris Serra, JL.; García Blázquez, E.; Atienza Vicente, CM. (2020). Evaluación comparativa mediante ensayos biomecánicos de anillos moldeables de ostomía. Metas de Enfermeria. 23(10):17-20. https://doi.org/10.35667/MetasEnf.2020.23.1003081683 es_ES
dc.description.accrualMethod S es_ES
dc.relation.publisherversion https://doi.org/10.35667/MetasEnf.2020.23.1003081683 es_ES
dc.description.upvformatpinicio 17 es_ES
dc.description.upvformatpfin 20 es_ES
dc.type.version info:eu-repo/semantics/publishedVersion es_ES
dc.description.volume 23 es_ES
dc.description.issue 10 es_ES
dc.relation.pasarela S\425894 es_ES


Este ítem aparece en la(s) siguiente(s) colección(ones)

Mostrar el registro sencillo del ítem