- -

Evaluación comparativa, mediante ensayos biomecánicos, de dispositivos de ostomía de dos piezas

RiuNet: Repositorio Institucional de la Universidad Politécnica de Valencia

Compartir/Enviar a

Citas

Estadísticas

  • Estadisticas de Uso

Evaluación comparativa, mediante ensayos biomecánicos, de dispositivos de ostomía de dos piezas

Mostrar el registro sencillo del ítem

Ficheros en el ítem

dc.contributor.author Gómez Pérez, Amelia Lucia es_ES
dc.contributor.author Panadero Morales, Raúl es_ES
dc.contributor.author García-Torres, Fernando es_ES
dc.contributor.author Solera Navarro, Mª Jesús es_ES
dc.contributor.author PERIS SERRA, JOSE LUIS es_ES
dc.contributor.author ATIENZA VICENTE, CARLOS MANUEL es_ES
dc.contributor.author García Blázquez, Eduardo es_ES
dc.date.accessioned 2021-11-05T12:36:56Z
dc.date.available 2021-11-05T12:36:56Z
dc.date.issued 2020-02 es_ES
dc.identifier.issn 1138-7262 es_ES
dc.identifier.uri http://hdl.handle.net/10251/176112
dc.description.abstract [ES] Objetivo: comparar las propiedades mecánicas de los dispositivos de ostomía de dos piezas más empleados en España (Coloplast -o Fabricante I- y Fabricante II), mediante la realización de ensayos mecánicos. Método: los ensayos se realizaron en el Instituto de Biomecánica de Valencia (IBV), empleándose una máquina universal de ensayos MTS INSIGHT/468, con unas condiciones ambientales controladas de temperatura (22-24 ºC) y de humedad (39-41%). El tamaño de la muestra para cada uno de los ensayos fue de 10 unidades para cada tipo de sistema. Se llevaron a cabo tres pruebas: 1) Ensayo de resistencia a la degradación del adhesivo en solución salina; 2) Ensayo de resistencia al estallido del canal de vaciado de las bolsas abiertas; 3) Ensayo de resistencia a la separación entre el disco y la bolsa. Resultados: en el ensayo de resistencia a la degradación del adhesivo en solución salina, los dos adhesivos, sometidos a periodos de degradación de 6 y 12 horas en solución salina a 37 ºC, presentaron diferencias significativas a favor del Fabricante I (Coloplast) para los dos periodos. En el ensayo de resistencia al estallido del canal de vaciado de las bolsas abiertas, con las bolsas llenas de agua, cerradas y pegadas sobre una plancha lisa, después de aplicar cargas de compresión hasta el estallido del canal, los dos sistemas no mostraron diferencias significativas. En el ensayo de resistencia a la separación entre el disco y la bolsa, ensamblada cada bolsa a su disco correspondiente y aplicadas cargas de tracción hasta la separación, también hubo diferencias significativas a favor del Fabricante I (Coloplast). Conclusión: se puede afirmar que ambos sistemas son seguros, pero el sistema Coloplast presenta mayor durabilidad ante la degradación por el efluente y mayor coeficiente de seguridad frente a la separación entre la bolsa y el disco. es_ES
dc.description.abstract [EN] Objective: to compare the mechanical characteristics of the two-piece ostomy systems most widely used in Spain: (Coloplast or Manufacturer I and Manufacturer II), through mechanical tests. Method: tests were conducted in the Instituto de Biomecánica de Valencia (IBV), using a MTS INSIGHT/468 universal test machine, under environmental conditions of controlled temperature (22-24 ºC) and humidity (39-41%). The sample size for each test was 10 units per each type of system. Three tests were conducted: 1) Resistance test to degradation of the adhesive in saline solution; 2) Resistance test to burst of the outlet in open pouches; 3) Resistance test for the separation between the disc and the pouch. Results: in the test of resistance to degradation of the adhesive in saline solution, both adhesives were submitted to 6 and 12-hour degradation periods in saline solution at 37 ºC, and significant differences were presented in favour of Manufacturer 1 (Coloplast) for both time periods. In the resistance test for the burst of the outlet in open pouches, the pouches were filled with water, closed and stuck on a flat plate; after applying compression charges until the outlet burst, both systems did not show any significant differences. In the resistance test for the separation between disc and pouch, each pouch was assembled with its disc, and traction charges were applied until their separation; there were significant differences in favour of Manufacturer I (Coloplast). Conclusion: it can be stated that both systems are safe, but the Coloplast system shows higher durability in terms of degradation by effluent, and a higher safety coefficient regarding the separation between pouch and disc. es_ES
dc.language Español es_ES
dc.publisher DAE.Difusion Avances Enfermeria es_ES
dc.relation.ispartof Metas de Enfermeria es_ES
dc.rights Reserva de todos los derechos es_ES
dc.subject Estoma es_ES
dc.subject Ostomía es_ES
dc.subject Dispositivo de ostomía es_ES
dc.subject Tipo de estoma es_ES
dc.subject Entorno periestomal es_ES
dc.subject Calidad de vida es_ES
dc.subject Stoma es_ES
dc.subject Ostomy es_ES
dc.subject Ostomy device es_ES
dc.subject Type of stoma es_ES
dc.subject Peristomal setting es_ES
dc.subject Quality of life es_ES
dc.subject.classification INGENIERIA MECANICA es_ES
dc.title Evaluación comparativa, mediante ensayos biomecánicos, de dispositivos de ostomía de dos piezas es_ES
dc.title.alternative Comparative evaluation through biomechanical tests of two-piece ostomy systems es_ES
dc.type Artículo es_ES
dc.identifier.doi 10.35667/MetasEnf.2019.23.1003081535 es_ES
dc.rights.accessRights Cerrado es_ES
dc.contributor.affiliation Universitat Politècnica de València. Departamento de Ingeniería Mecánica y de Materiales - Departament d'Enginyeria Mecànica i de Materials es_ES
dc.description.bibliographicCitation Gómez Pérez, AL.; Panadero Morales, R.; García-Torres, F.; Solera Navarro, MJ.; Peris Serra, JL.; Atienza Vicente, CM.; García Blázquez, E. (2020). Evaluación comparativa, mediante ensayos biomecánicos, de dispositivos de ostomía de dos piezas. Metas de Enfermeria. 23(1):18-23. https://doi.org/10.35667/MetasEnf.2019.23.1003081535 es_ES
dc.description.accrualMethod S es_ES
dc.relation.publisherversion https://doi.org/10.35667/MetasEnf.2019.23.1003081535 es_ES
dc.description.upvformatpinicio 18 es_ES
dc.description.upvformatpfin 23 es_ES
dc.type.version info:eu-repo/semantics/publishedVersion es_ES
dc.description.volume 23 es_ES
dc.description.issue 1 es_ES
dc.relation.pasarela S\432595 es_ES


Este ítem aparece en la(s) siguiente(s) colección(ones)

Mostrar el registro sencillo del ítem