- -

Time reconstruction study using tubes of response backprojectors in List Mode algorithms, applied to amonolithic crystals based breast PET

RiuNet: Repositorio Institucional de la Universidad Politécnica de Valencia

Compartir/Enviar a

Citas

Estadísticas

  • Estadisticas de Uso

Time reconstruction study using tubes of response backprojectors in List Mode algorithms, applied to amonolithic crystals based breast PET

Mostrar el registro sencillo del ítem

Ficheros en el ítem

dc.contributor.author Moliner, L. es_ES
dc.contributor.author Correcher, C. es_ES
dc.contributor.author González Martínez, Antonio Javier es_ES
dc.contributor.author Conde, P. es_ES
dc.contributor.author Crespo, E. es_ES
dc.contributor.author Hernandez, L. es_ES
dc.contributor.author Rigla, J. P. es_ES
dc.contributor.author Rodriguez-Alvarez, M. J. es_ES
dc.contributor.author Sanchez, F. es_ES
dc.contributor.author Soriano, A. es_ES
dc.contributor.author Iborra, A. es_ES
dc.contributor.author Bellido, P. es_ES
dc.contributor.author Seimetz, Michael es_ES
dc.contributor.author Vidal San Sebastian, Luis Fernando es_ES
dc.contributor.author Benlloch Baviera, Jose María es_ES
dc.date.accessioned 2021-11-11T07:29:39Z
dc.date.available 2021-11-11T07:29:39Z
dc.date.issued 2013-11-02 es_ES
dc.identifier.isbn 978-1-4799-0534-8 es_ES
dc.identifier.uri http://hdl.handle.net/10251/176836
dc.description.abstract [EN] The LM-EM algorithm has the advantage to calculate the emission probabilities needed for the reconstruction process on the fly, without the need of a pre-calculated system matrix. The reconstruction time for this algorithm strongly depends on the used backprojector and the available statistics. This algorithm when implemented in systems using monolithic crystals to detect gamma radiation allows one to extensively exploit the virtual pixilation feature, not available for systems based on pixilated crystals. In this work we present a backprojector for LM-EM, the TOR method, which achieves a tradeoff between computational efficiency and image quality. Its temporal subset algorithm optimization (LM-OS) has also been implemented in order to achieve real-time reconstructions. To evaluate the performances of LM-OS algorithm with the TOR method backprojector and only with one iteration on the datasets, studies based on the system spatial resolution, uniformity, and contrast coefficients were carried out and they were compared with those obtained with LM-EM and MLEM algorithms using twelve iteration. Finally, a study on reconstruction time using LM-OS has been performed with breast patients data es_ES
dc.description.sponsorship Project funded by the Spanish Ministry of Economy and Competitiveness and co-funded with FEDER's funds within the INNPACTO 2011 program. This work was supported by the Spanish Plan Nacional de Investigación Científica, Desarrollo e Innovación Tecnológica (I+D+i) under Grant No. FIS2010-21216-CO2-01 and the Valencian Local Government under Grants PROMETEOII/2013/010 and ISIC 2011/013 es_ES
dc.language Inglés es_ES
dc.publisher IEEE es_ES
dc.relation.ispartof 2013 IEEE Nuclear Science Symposium and Medical Imaging Conference (2013 NSS/MIC) es_ES
dc.rights Reserva de todos los derechos es_ES
dc.subject.classification MATEMATICA APLICADA es_ES
dc.title Time reconstruction study using tubes of response backprojectors in List Mode algorithms, applied to amonolithic crystals based breast PET es_ES
dc.type Comunicación en congreso es_ES
dc.type Capítulo de libro es_ES
dc.identifier.doi 10.1109/NSSMIC.2013.6829372 es_ES
dc.relation.projectID info:eu-repo/grantAgreement/GVA//ISIC 2011%2F013/ es_ES
dc.relation.projectID info:eu-repo/grantAgreement/MICINN//FIS2010-21216-C02-01//DESARROLLO DEL DETECTOR PET/RM PARA DIAGNOSTICO DE ENFERMEDADES NEURODEGENERATIVAS/ es_ES
dc.relation.projectID info:eu-repo/grantAgreement/GVA//PROMETEOII%2F2013%2F010//Desarrollo de nuevas terapias para tumores cerebrales/ es_ES
dc.rights.accessRights Abierto es_ES
dc.contributor.affiliation Universitat Politècnica de València. Departamento de Matemática Aplicada - Departament de Matemàtica Aplicada es_ES
dc.contributor.affiliation Universitat Politècnica de València. Instituto de Instrumentación para Imagen Molecular - Institut d'Instrumentació per a Imatge Molecular es_ES
dc.description.bibliographicCitation Moliner, L.; Correcher, C.; González Martínez, AJ.; Conde, P.; Crespo, E.; Hernandez, L.; Rigla, JP.... (2013). Time reconstruction study using tubes of response backprojectors in List Mode algorithms, applied to amonolithic crystals based breast PET. IEEE. 14-18. https://doi.org/10.1109/NSSMIC.2013.6829372 es_ES
dc.description.accrualMethod S es_ES
dc.relation.conferencename IEEE Nuclear Science Symposium and Medical Imaging Conference, and Room-Temperature Semiconductor X-Ray and Gamma-Ray Detectors Workshop (2013 IEEE NSS/MIC/RTSD) es_ES
dc.relation.conferencedate Octubre 27-Noviembre 02,2013 es_ES
dc.relation.conferenceplace Seoul, Korea es_ES
dc.relation.publisherversion https://doi.org/10.1109/NSSMIC.2013.6829372 es_ES
dc.description.upvformatpinicio 14 es_ES
dc.description.upvformatpfin 18 es_ES
dc.type.version info:eu-repo/semantics/publishedVersion es_ES
dc.relation.pasarela S\268535 es_ES
dc.contributor.funder Generalitat Valenciana es_ES
dc.contributor.funder Ministerio de Ciencia e Innovación es_ES


Este ítem aparece en la(s) siguiente(s) colección(ones)

Mostrar el registro sencillo del ítem