Mostrar el registro sencillo del ítem
dc.contributor.author | Moliner, L. | es_ES |
dc.contributor.author | Correcher, C. | es_ES |
dc.contributor.author | González Martínez, Antonio Javier | es_ES |
dc.contributor.author | Conde, P. | es_ES |
dc.contributor.author | Crespo, E. | es_ES |
dc.contributor.author | Hernandez, L. | es_ES |
dc.contributor.author | Rigla, J. P. | es_ES |
dc.contributor.author | Rodriguez-Alvarez, M. J. | es_ES |
dc.contributor.author | Sanchez, F. | es_ES |
dc.contributor.author | Soriano, A. | es_ES |
dc.contributor.author | Iborra, A. | es_ES |
dc.contributor.author | Bellido, P. | es_ES |
dc.contributor.author | Seimetz, Michael | es_ES |
dc.contributor.author | Vidal San Sebastian, Luis Fernando | es_ES |
dc.contributor.author | Benlloch Baviera, Jose María | es_ES |
dc.date.accessioned | 2021-11-11T07:29:39Z | |
dc.date.available | 2021-11-11T07:29:39Z | |
dc.date.issued | 2013-11-02 | es_ES |
dc.identifier.isbn | 978-1-4799-0534-8 | es_ES |
dc.identifier.uri | http://hdl.handle.net/10251/176836 | |
dc.description.abstract | [EN] The LM-EM algorithm has the advantage to calculate the emission probabilities needed for the reconstruction process on the fly, without the need of a pre-calculated system matrix. The reconstruction time for this algorithm strongly depends on the used backprojector and the available statistics. This algorithm when implemented in systems using monolithic crystals to detect gamma radiation allows one to extensively exploit the virtual pixilation feature, not available for systems based on pixilated crystals. In this work we present a backprojector for LM-EM, the TOR method, which achieves a tradeoff between computational efficiency and image quality. Its temporal subset algorithm optimization (LM-OS) has also been implemented in order to achieve real-time reconstructions. To evaluate the performances of LM-OS algorithm with the TOR method backprojector and only with one iteration on the datasets, studies based on the system spatial resolution, uniformity, and contrast coefficients were carried out and they were compared with those obtained with LM-EM and MLEM algorithms using twelve iteration. Finally, a study on reconstruction time using LM-OS has been performed with breast patients data | es_ES |
dc.description.sponsorship | Project funded by the Spanish Ministry of Economy and Competitiveness and co-funded with FEDER's funds within the INNPACTO 2011 program. This work was supported by the Spanish Plan Nacional de Investigación Científica, Desarrollo e Innovación Tecnológica (I+D+i) under Grant No. FIS2010-21216-CO2-01 and the Valencian Local Government under Grants PROMETEOII/2013/010 and ISIC 2011/013 | es_ES |
dc.language | Inglés | es_ES |
dc.publisher | IEEE | es_ES |
dc.relation.ispartof | 2013 IEEE Nuclear Science Symposium and Medical Imaging Conference (2013 NSS/MIC) | es_ES |
dc.rights | Reserva de todos los derechos | es_ES |
dc.subject.classification | MATEMATICA APLICADA | es_ES |
dc.title | Time reconstruction study using tubes of response backprojectors in List Mode algorithms, applied to amonolithic crystals based breast PET | es_ES |
dc.type | Comunicación en congreso | es_ES |
dc.type | Capítulo de libro | es_ES |
dc.identifier.doi | 10.1109/NSSMIC.2013.6829372 | es_ES |
dc.relation.projectID | info:eu-repo/grantAgreement/GVA//ISIC 2011%2F013/ | es_ES |
dc.relation.projectID | info:eu-repo/grantAgreement/MICINN//FIS2010-21216-C02-01//DESARROLLO DEL DETECTOR PET/RM PARA DIAGNOSTICO DE ENFERMEDADES NEURODEGENERATIVAS/ | es_ES |
dc.relation.projectID | info:eu-repo/grantAgreement/GVA//PROMETEOII%2F2013%2F010//Desarrollo de nuevas terapias para tumores cerebrales/ | es_ES |
dc.rights.accessRights | Abierto | es_ES |
dc.contributor.affiliation | Universitat Politècnica de València. Departamento de Matemática Aplicada - Departament de Matemàtica Aplicada | es_ES |
dc.contributor.affiliation | Universitat Politècnica de València. Instituto de Instrumentación para Imagen Molecular - Institut d'Instrumentació per a Imatge Molecular | es_ES |
dc.description.bibliographicCitation | Moliner, L.; Correcher, C.; González Martínez, AJ.; Conde, P.; Crespo, E.; Hernandez, L.; Rigla, JP.... (2013). Time reconstruction study using tubes of response backprojectors in List Mode algorithms, applied to amonolithic crystals based breast PET. IEEE. 14-18. https://doi.org/10.1109/NSSMIC.2013.6829372 | es_ES |
dc.description.accrualMethod | S | es_ES |
dc.relation.conferencename | IEEE Nuclear Science Symposium and Medical Imaging Conference, and Room-Temperature Semiconductor X-Ray and Gamma-Ray Detectors Workshop (2013 IEEE NSS/MIC/RTSD) | es_ES |
dc.relation.conferencedate | Octubre 27-Noviembre 02,2013 | es_ES |
dc.relation.conferenceplace | Seoul, Korea | es_ES |
dc.relation.publisherversion | https://doi.org/10.1109/NSSMIC.2013.6829372 | es_ES |
dc.description.upvformatpinicio | 14 | es_ES |
dc.description.upvformatpfin | 18 | es_ES |
dc.type.version | info:eu-repo/semantics/publishedVersion | es_ES |
dc.relation.pasarela | S\268535 | es_ES |
dc.contributor.funder | Generalitat Valenciana | es_ES |
dc.contributor.funder | Ministerio de Ciencia e Innovación | es_ES |