- -

Time Variability of P-wave Features from the Preoperative Electrocardiogram Predicts Recurrence After Catheter Cryoablation of Atrial Fibrillation

RiuNet: Repositorio Institucional de la Universidad Politécnica de Valencia

Compartir/Enviar a

Citas

Estadísticas

  • Estadisticas de Uso

Time Variability of P-wave Features from the Preoperative Electrocardiogram Predicts Recurrence After Catheter Cryoablation of Atrial Fibrillation

Mostrar el registro sencillo del ítem

Ficheros en el ítem

dc.contributor.author Ruiz, Antonio es_ES
dc.contributor.author Arias, Miguel A. es_ES
dc.contributor.author Puchol, Alberto es_ES
dc.contributor.author Pachón, Marta I. es_ES
dc.contributor.author Rieta, J J es_ES
dc.contributor.author Alcaraz, Raúl es_ES
dc.date.accessioned 2021-12-20T08:39:41Z
dc.date.available 2021-12-20T08:39:41Z
dc.date.issued 2020-10-30 es_ES
dc.identifier.isbn 978-1-7281-8803-4 es_ES
dc.identifier.uri http://hdl.handle.net/10251/178589
dc.description.abstract [EN] Pulmonary vein isolation is nowadays the cornerstone for the treatment of paroxysmal atrial fibrillation (AF). However, its success rate is not as high as clinically desirable, and repeated procedures are often required. In this context, the development of noninvasive, pre-ablation predictors of the procedure failure is essential to enable tailored approaches. For that purpose several P-wave features have been analyzed from short electrocardiogram (ECG) recordings, but their time variability has not been studied yet. Hence, this work explores the ability of time variability of two common P-wave parameters, such as duration and amplitude, to anticipate cryoablation failure. Before ablation, a standard 12-lead ECG was recorded continuously for 5 minutes from 45 paroxysmal AF patients. All P-waves in lead II were delineated with an automatic algorithm. Duration and amplitude of all waves were computed, and then mean, standard deviation (std), and coefficient of variation (CV) were obtained for both parameters and correlated with ablation outcome after a follow-up of 9 months. The CV for both P-waves features reported the best separation between the patients who maintained sinus rhythm and those who relapsed to AF. Moreover, improvements about 10% in diagnostic ability were obtained by the CV with regards to the mean, reaching values about 70%. These results suggest that time variability of the P-wave can provide new insights about atrial conduction heterogeneity, which could be helpful in improving the selection strategy of optimal candidates for cryoablation. es_ES
dc.description.sponsorship This research has been supported by grants DPI2017-83952-C3 from MINECO/AEI/FEDER EU, SBPLY/17/180501/000411 from Junta de Comunidades de Castilla-la Mancha and AICO/2019/036 from Generalitat Valenciana. es_ES
dc.language Inglés es_ES
dc.publisher IEEE es_ES
dc.relation.ispartof 2020 International Conference on e-Health and Bioengineering (EHB) es_ES
dc.rights Reserva de todos los derechos es_ES
dc.subject Atrial Fibrillation es_ES
dc.subject Cryoablation es_ES
dc.subject Electrocardiogram es_ES
dc.subject P-wave es_ES
dc.subject Time Variability es_ES
dc.subject.classification TECNOLOGIA ELECTRONICA es_ES
dc.title Time Variability of P-wave Features from the Preoperative Electrocardiogram Predicts Recurrence After Catheter Cryoablation of Atrial Fibrillation es_ES
dc.type Comunicación en congreso es_ES
dc.type Capítulo de libro es_ES
dc.identifier.doi 10.1109/EHB50910.2020.9280224 es_ES
dc.relation.projectID info:eu-repo/grantAgreement/AEI/Plan Estatal de Investigación Científica y Técnica y de Innovación 2013-2016/DPI2017-83952-C3-1-R/ES/ESTUDIO MULTICENTRICO PARA LA EVALUACION DEL SUSTRATO ARRITMOGENICO EN PACIENTES CON FIBRILACION AURICULAR. APLICACION A LA ABLACION POR CATETER/ es_ES
dc.relation.projectID info:eu-repo/grantAgreement/JCCM//SBPLY%2F17%2F180501%2F000411//Caracterización del sustrato auricular mediante análisis de señal como herramienta de asistencia procedimental en ablación por catéter de fibrilación auricular/ es_ES
dc.relation.projectID info:eu-repo/grantAgreement///AICO%2F2019%2F036//METODOS DE DIAGNOSTICO Y TERAPIA PERSONALIZADA EN ABLACION POR CATETER DE ARRITMIAS CARDIACAS/ es_ES
dc.rights.accessRights Cerrado es_ES
dc.contributor.affiliation Universitat Politècnica de València. Departamento de Ingeniería Electrónica - Departament d'Enginyeria Electrònica es_ES
dc.description.bibliographicCitation Ruiz, A.; Arias, MA.; Puchol, A.; Pachón, MI.; Rieta, JJ.; Alcaraz, R. (2020). Time Variability of P-wave Features from the Preoperative Electrocardiogram Predicts Recurrence After Catheter Cryoablation of Atrial Fibrillation. IEEE. 1-4. https://doi.org/10.1109/EHB50910.2020.9280224 es_ES
dc.description.accrualMethod S es_ES
dc.relation.conferencename 8th International Conference on e-Health and Bioengineering (EHB 2020) es_ES
dc.relation.conferencedate Octubre 29-30,2020 es_ES
dc.relation.conferenceplace Online es_ES
dc.relation.publisherversion https://doi.org/10.1109/EHB50910.2020.9280224 es_ES
dc.description.upvformatpinicio 1 es_ES
dc.description.upvformatpfin 4 es_ES
dc.type.version info:eu-repo/semantics/publishedVersion es_ES
dc.relation.pasarela S\433197 es_ES
dc.contributor.funder European Regional Development Fund es_ES
dc.contributor.funder Junta de Comunidades de Castilla-La Mancha es_ES


Este ítem aparece en la(s) siguiente(s) colección(ones)

Mostrar el registro sencillo del ítem