Mostrar el registro sencillo del ítem
dc.contributor.author | Fuster Escuder, José Miguel | es_ES |
dc.contributor.author | Pérez-López, Sergio | es_ES |
dc.contributor.author | Belmar Ibáñez, Francisco | es_ES |
dc.contributor.author | Candelas Valiente, Pilar | es_ES |
dc.date.accessioned | 2022-01-21T19:03:43Z | |
dc.date.available | 2022-01-21T19:03:43Z | |
dc.date.issued | 2021-08 | es_ES |
dc.identifier.uri | http://hdl.handle.net/10251/180094 | |
dc.description.abstract | [EN] In this work, we analyze the effect of predistortion techniques on the focusing profile of Fresnel Zone Plates (FZPs) in ultrasound applications. This novel predistortion method is based on either increasing or decreasing the width of some of the FZP Fresnel rings by a certain amount. We investigate how the magnitude of the predistortion, as well as the number and location of the predistorted rings, influences the lens focusing profile. This focusing profile can be affected in different ways depending on the area of the lens where the predistortion is applied. It is shown that when the inner area of the lens, closer to its center, is predistorted, this technique allows the control of the focal depth at the main focus. However, when the predistortion is applied to an area farther from the center of the lens, the acoustic intensity distribution among the main focus and the closest adjacent secondary foci can be tailored at a certain degree. This predistortion technique shows great potential and can be used to control, modify and shape the FZP focusing profile in both industrial and therapeutic applications. | es_ES |
dc.description.sponsorship | This work has been supported by Spanish MICINN RTI2018-100792-B-I00 project and Generalitat Valenciana AICO/2020/139 project. | es_ES |
dc.language | Inglés | es_ES |
dc.publisher | MDPI AG | es_ES |
dc.relation.ispartof | Sensors | es_ES |
dc.rights | Reconocimiento (by) | es_ES |
dc.subject | Fresnel Zone Plate | es_ES |
dc.subject | Acoustic focusing | es_ES |
dc.subject | Acoustic lens | es_ES |
dc.subject | Focusing profile | es_ES |
dc.subject.classification | TEORIA DE LA SEÑAL Y COMUNICACIONES | es_ES |
dc.subject.classification | FISICA APLICADA | es_ES |
dc.title | Analysis of Predistortion Techniques on Fresnel Zone Plates in Ultrasound Applications | es_ES |
dc.type | Artículo | es_ES |
dc.identifier.doi | 10.3390/s21155066 | es_ES |
dc.relation.projectID | info:eu-repo/grantAgreement/AEI/Plan Estatal de Investigación Científica y Técnica y de Innovación 2017-2020/RTI2018-100792-B-I00/ES/FOCALIZACION Y CONFORMACION DE HACES DE ULTRASONIDOS MEDIANTE LENTES PLANAS/ | es_ES |
dc.relation.projectID | info:eu-repo/grantAgreement/GENERALITAT VALENCIANA//AICO%2F2020%2F139//DISEÑO DE LENTES MULTIFOCALES PARA FOCALIZACIÓN EN ULTRASONIDOS/ | es_ES |
dc.rights.accessRights | Abierto | es_ES |
dc.contributor.affiliation | Universitat Politècnica de València. Departamento de Comunicaciones - Departament de Comunicacions | es_ES |
dc.contributor.affiliation | Universitat Politècnica de València. Departamento de Física Aplicada - Departament de Física Aplicada | es_ES |
dc.description.bibliographicCitation | Fuster Escuder, JM.; Pérez-López, S.; Belmar Ibáñez, F.; Candelas Valiente, P. (2021). Analysis of Predistortion Techniques on Fresnel Zone Plates in Ultrasound Applications. Sensors. 21(15):1-12. https://doi.org/10.3390/s21155066 | es_ES |
dc.description.accrualMethod | S | es_ES |
dc.relation.publisherversion | https://doi.org/10.3390/s21155066 | es_ES |
dc.description.upvformatpinicio | 1 | es_ES |
dc.description.upvformatpfin | 12 | es_ES |
dc.type.version | info:eu-repo/semantics/publishedVersion | es_ES |
dc.description.volume | 21 | es_ES |
dc.description.issue | 15 | es_ES |
dc.identifier.eissn | 1424-8220 | es_ES |
dc.identifier.pmid | 34372303 | es_ES |
dc.identifier.pmcid | PMC8347042 | es_ES |
dc.relation.pasarela | S\444758 | es_ES |
dc.contributor.funder | GENERALITAT VALENCIANA | es_ES |
dc.contributor.funder | AGENCIA ESTATAL DE INVESTIGACION | es_ES |
dc.contributor.funder | UNIVERSIDAD POLITECNICA DE VALENCIA | es_ES |
upv.costeAPC | 2420 | es_ES |