Comments on "SPICE Model of Photomultiplier Tube Under Different Bias Conditions"

RiuNet: Repositorio Institucional de la Universidad Politécnica de Valencia

Compartir/Enviar a

Citas

Estadísticas

  • Estadisticas de Uso

Comments on "SPICE Model of Photomultiplier Tube Under Different Bias Conditions"

Mostrar el registro sencillo del ítem

Ficheros en el ítem

dc.contributor.author Hueso-González, Fernando es_ES
dc.contributor.author Ginestar Peiro, Damián es_ES
dc.contributor.author Hueso Pagoaga, José Luís es_ES
dc.contributor.author Riera Guasp, Jaime es_ES
dc.date.accessioned 2022-02-03T19:04:53Z
dc.date.available 2022-02-03T19:04:53Z
dc.date.issued 2021-08-01 es_ES
dc.identifier.issn 1530-437X es_ES
dc.identifier.uri http://hdl.handle.net/10251/180481
dc.description © 2021 IEEE. Personal use of this material is permitted. Permissíon from IEEE must be obtained for all other uses, in any current or future media, including reprinting/republishing this material for advertisíng or promotional purposes, creating new collective works, for resale or redistribution to servers or lists, or reuse of any copyrighted component of this work in other works. es_ES
dc.description.abstract [EN] The paper ¿SPICE Model of Photomultiplier Tube Under Different Bias Conditions¿ is commented. We revisit the mathematical formulation to compensate for some ambiguities in the original manuscript, and point out some inconsistencies in the results and reproducibility of the simulations, as well as in the optimized parameters originally obtained with the PSPICE simulation engine. All simulations are recalculated with the NGSPICE software using the corrected parameters and compared against the original figures. The reproducibility of our simulations is independently verified with PSPICE, as well as by numerically solving the analytical system of non-linear equations using Newton¿s method within MATLAB es_ES
dc.description.sponsorship This work was supported by the Conselleria de Educacion, Investigacion, Cultura y Deporte (Generalitat Valenciana) under Grant CDEIGENT/2019/011 es_ES
dc.language Inglés es_ES
dc.publisher Institute of Electrical and Electronics Engineers es_ES
dc.relation.ispartof IEEE Sensors Journal es_ES
dc.rights Reserva de todos los derechos es_ES
dc.subject.classification MATEMATICA APLICADA es_ES
dc.subject.classification FISICA APLICADA es_ES
dc.title Comments on "SPICE Model of Photomultiplier Tube Under Different Bias Conditions" es_ES
dc.type Artículo es_ES
dc.identifier.doi 10.1109/JSEN.2021.3062428 es_ES
dc.relation.projectID info:eu-repo/grantAgreement/GVA//CDEIGENT%2F2019%2F011/ es_ES
dc.rights.accessRights Abierto es_ES
dc.contributor.affiliation Universitat Politècnica de València. Departamento de Matemática Aplicada - Departament de Matemàtica Aplicada es_ES
dc.contributor.affiliation Universitat Politècnica de València. Departamento de Física Aplicada - Departament de Física Aplicada es_ES
dc.description.bibliographicCitation Hueso-González, F.; Ginestar Peiro, D.; Hueso Pagoaga, JL.; Riera Guasp, J. (2021). Comments on "SPICE Model of Photomultiplier Tube Under Different Bias Conditions". IEEE Sensors Journal. 21(15):17395-17402. https://doi.org/10.1109/JSEN.2021.3062428 es_ES
dc.description.accrualMethod S es_ES
dc.relation.publisherversion https://doi.org/10.1109/JSEN.2021.3062428 es_ES
dc.description.upvformatpinicio 17395 es_ES
dc.description.upvformatpfin 17402 es_ES
dc.type.version info:eu-repo/semantics/publishedVersion es_ES
dc.description.volume 21 es_ES
dc.description.issue 15 es_ES
dc.relation.pasarela S\444945 es_ES
dc.contributor.funder Generalitat Valenciana es_ES


Este ítem aparece en la(s) siguiente(s) colección(ones)