- -

Study on How Catheter Ablation Affects Atrial Structures in Patients with Paroxysmal Atrial Fibrillation: The Case of the Coronary Sinus

RiuNet: Institutional repository of the Polithecnic University of Valencia

Share/Send to

Cited by

Statistics

  • Estadisticas de Uso

Study on How Catheter Ablation Affects Atrial Structures in Patients with Paroxysmal Atrial Fibrillation: The Case of the Coronary Sinus

Show full item record

Vraka, A.; Bertomeu-González, V.; Osca, J.; Ravelli, F.; Alcaraz, R.; Rieta, JJ. (2020). Study on How Catheter Ablation Affects Atrial Structures in Patients with Paroxysmal Atrial Fibrillation: The Case of the Coronary Sinus. IEEE. 1-4. https://doi.org/10.1109/EHB50910.2020.9280243

Por favor, use este identificador para citar o enlazar este ítem: http://hdl.handle.net/10251/180684

Files in this item

Item Metadata

Title: Study on How Catheter Ablation Affects Atrial Structures in Patients with Paroxysmal Atrial Fibrillation: The Case of the Coronary Sinus
Author: Vraka, Aikaterini Bertomeu-González, Vicente Osca, Joaquín Ravelli, Flavia Alcaraz, Raúl Rieta, J J
UPV Unit: Universitat Politècnica de València. Departamento de Ingeniería Electrónica - Departament d'Enginyeria Electrònica
Issued date:
Abstract:
[EN] It has been shown that substrate modification due to catheter ablation (CA), the first-line treatment of paroxysmal atrial fibrillation (PAF), provokes alterations in P-wave features of the surface electrocardiogram. ...[+]
Subjects: Atrial fibrillation , Catheter ablation , Invasive recordings , P-wave , Coronary sinus
Copyrigths: Cerrado
ISBN: 978-1-7281-8803-4
Source:
2020 E-Health and Bioengineering Conference (EHB).
DOI: 10.1109/EHB50910.2020.9280243
Publisher:
IEEE
Publisher version: https://doi.org/10.1109/EHB50910.2020.9280243
Conference name: 8th International Conference on e-Health and Bioengineering (EHB 2020)
Conference place: Online
Conference date: Octubre 29-30,2020
Project ID:
info:eu-repo/grantAgreement/AEI/Plan Estatal de Investigación Científica y Técnica y de Innovación 2013-2016/DPI2017-83952-C3-1-R/ES/ESTUDIO MULTICENTRICO PARA LA EVALUACION DEL SUSTRATO ARRITMOGENICO EN PACIENTES CON FIBRILACION AURICULAR. APLICACION A LA ABLACION POR CATETER/
info:eu-repo/grantAgreement/JCCM//SBPLY%2F17%2F180501%2F000411/ES/Caracterización del sustrato auricular mediante análisis de señal como herramienta de asistencia procedimental en ablación por catéter de fibrilación auricular/
info:eu-repo/grantAgreement/GVA//AICO%2F2019%2F036/ES/METODOS DE DIAGNOSTICO Y TERAPIA PERSONALIZADA EN ABLACION POR CATETER DE ARRITMIAS CARDIACAS/
Thanks:
Research supported by grants DPI2017-83952-C3 from MINECO/AEI/FEDER UE, SBPLY/17/180501/000411 from JCCLM and AICO/2019/036 from GVA.
Type: Comunicación en congreso Capítulo de libro

recommendations

 

This item appears in the following Collection(s)

Show full item record