- -

Effect of Reducing the Number of Leads from Body Surface PotentialMapping in ComputerModels of Atrial Arrhythmias

RiuNet: Repositorio Institucional de la Universidad Politécnica de Valencia

Compartir/Enviar a

Citas

Estadísticas

  • Estadisticas de Uso

Effect of Reducing the Number of Leads from Body Surface PotentialMapping in ComputerModels of Atrial Arrhythmias

Mostrar el registro sencillo del ítem

Ficheros en el ítem

dc.contributor.author Marques, Victor G es_ES
dc.contributor.author Rodrigo, Miguel es_ES
dc.contributor.author Guillem Sánchez, María Salud es_ES
dc.contributor.author Salinet, Joao es_ES
dc.date.accessioned 2022-03-09T08:04:12Z
dc.date.available 2022-03-09T08:04:12Z
dc.date.issued 2019-09-11 es_ES
dc.identifier.isbn 978-1-7281-6936-1 es_ES
dc.identifier.issn 2325-887X es_ES
dc.identifier.uri http://hdl.handle.net/10251/181330
dc.description.abstract [EN] Body surface potential mapping (BSPM) can be an important tool in ablation therapy planning. Results obtained with high resolution (HR) computer models must be translated to realistic numbers of leads. This study aims to evaluate the impact on atrial tachycardia (AT), flutter (AFL) and fibrillation (AF) characterization by reducing the number of BSPM leads. 19 realistic computer simulations with 567 leads (HR) have been used to characterize the arrhythmias concerning the dominant frequencies (DF) and phase singularity point (SP) distributions. DF maps were generated combining Welch periodogram and activation detection with wavelet transform modulus maxima. Phase was calculated with Hilbert transform on signals filtered around the highest DF (±1Hz); dynamics of SPs were analyzed using histograms (heatmaps, HMs) and connecting SPs along time (filaments). The analyses were reproduced for 6 layouts with 252 to 16 leads and results were compared using the structural similarity index (SSIM), sensitivity and precision in SP detection and analyzing features extracted from the maps. SSIM was lower in AF than in AFL or AT for DF maps and HMs, but was in average above 0.6 for layouts with 32 leads or more. In HMs, a loss in spatial resolution with fewer leads is reflected in decreasing values for sensitivity and precision. Features from DF maps, filaments or HMs were statistically equivalent in all layouts. es_ES
dc.description.sponsorship This work was financed by the São Paulo Research Foundation (FAPESP), grant number 2017/19775-3. es_ES
dc.language Inglés es_ES
dc.publisher IEEE es_ES
dc.relation.ispartof 2019 Computing in Cardiology (CinC). Proceedings es_ES
dc.rights Reserva de todos los derechos es_ES
dc.title Effect of Reducing the Number of Leads from Body Surface PotentialMapping in ComputerModels of Atrial Arrhythmias es_ES
dc.type Comunicación en congreso es_ES
dc.type Artículo es_ES
dc.type Capítulo de libro es_ES
dc.identifier.doi 10.22489/CinC.2019.099 es_ES
dc.relation.projectID info:eu-repo/grantAgreement/FAPESP//2017%2F19775-3/ es_ES
dc.rights.accessRights Cerrado es_ES
dc.description.bibliographicCitation Marques, VG.; Rodrigo, M.; Guillem Sánchez, MS.; Salinet, J. (2019). Effect of Reducing the Number of Leads from Body Surface PotentialMapping in ComputerModels of Atrial Arrhythmias. IEEE. 1-4. https://doi.org/10.22489/CinC.2019.099 es_ES
dc.description.accrualMethod S es_ES
dc.relation.conferencename 46th Computing in Cardiology Conference (CinC 2019) es_ES
dc.relation.conferencedate Septiembre 08-11,2019 es_ES
dc.relation.conferenceplace Singapore es_ES
dc.relation.publisherversion https://doi.org/10.22489/CinC.2019.099 es_ES
dc.description.upvformatpinicio 1 es_ES
dc.description.upvformatpfin 4 es_ES
dc.type.version info:eu-repo/semantics/publishedVersion es_ES
dc.relation.pasarela S\409196 es_ES
dc.contributor.funder Fundação de Amparo à Pesquisa do Estado de São Paulo es_ES


Este ítem aparece en la(s) siguiente(s) colección(ones)

Mostrar el registro sencillo del ítem