A Methodology for the Multi-Point Characterization of Short-Term Temperature Fluctuations in Complex Microclimates Based on the European Standard EN 15757:2010: Application to the Archaeological Museum of L'Almoina (Valencia, Spain)

RiuNet: Repositorio Institucional de la Universidad Politécnica de Valencia

Compartir/Enviar a

Citas

Estadísticas

  • Estadisticas de Uso

A Methodology for the Multi-Point Characterization of Short-Term Temperature Fluctuations in Complex Microclimates Based on the European Standard EN 15757:2010: Application to the Archaeological Museum of L'Almoina (Valencia, Spain)

Mostrar el registro sencillo del ítem

Ficheros en el ítem

dc.contributor.author Díaz-Arellano, Ignacio es_ES
dc.contributor.author Zarzo Castelló, Manuel es_ES
dc.contributor.author García Diego, Fernando Juan es_ES
dc.contributor.author Perles, Angel es_ES
dc.date.accessioned 2022-05-12T18:06:31Z
dc.date.available 2022-05-12T18:06:31Z
dc.date.issued 2021-11 es_ES
dc.identifier.uri http://hdl.handle.net/10251/182563
dc.description.abstract [EN] The monitoring and control of thermo-hygrometric indoor conditions is necessary for an adequate preservation of cultural heritage. The European standard EN 15757:2010 specifies a procedure for determining if seasonal patterns of relative humidity (RH) and temperature are adequate for the long-term preservation of hygroscopic materials on display at museums, archives, libraries or heritage buildings. This procedure is based on the characterization of the seasonal patterns and the calculation of certain control limits, so that it is possible to assess whether certain changes in the microclimate can be harmful for the preventive conservation of artworks, which would lead to the implementation of corrective actions. In order to discuss the application of this standard, 27 autonomous data-loggers were located in different points at the Archaeological Museum of l¿Almoina (Valencia). The HVAC system (heating, ventilation and air conditioning) at the museum tries to reach certain homogeneous environment, which becomes a challenge because parts of the ruins are covered by a skylight that produces a greenhouse effect in summer, resulting in severe thermo-hygrometric gradients. Based on the analysis of temperatures recorded during 16 months, the air conditions in this museum are discussed according to the standard EN 15757:2010, and some corrective measures are proposed to improve the conservation conditions. Although this standard is basically intended for data recorded from a single sensor, an alternative approach proposed in this work is to find zones inside the museum with a homogeneous microclimate and to discuss next the average values collected in each area. A methodology is presented to optimize the application of this standard in places with a complex microclimate like this case, when multiple sensors are located at different positions. es_ES
dc.description.sponsorship This research was funded by the European Unions Horizon 2020 research and innovation program under grant agreement No. 814624. es_ES
dc.language Inglés es_ES
dc.publisher MDPI AG es_ES
dc.relation.ispartof Sensors es_ES
dc.rights Reconocimiento (by) es_ES
dc.subject Cultural heritage es_ES
dc.subject Microclimate monitoring es_ES
dc.subject Preventive conservation es_ES
dc.subject EN 15757:2010 es_ES
dc.subject.classification ARQUITECTURA Y TECNOLOGIA DE COMPUTADORES es_ES
dc.subject.classification FISICA APLICADA es_ES
dc.subject.classification ESTADISTICA E INVESTIGACION OPERATIVA es_ES
dc.title A Methodology for the Multi-Point Characterization of Short-Term Temperature Fluctuations in Complex Microclimates Based on the European Standard EN 15757:2010: Application to the Archaeological Museum of L'Almoina (Valencia, Spain) es_ES
dc.type Artículo es_ES
dc.identifier.doi 10.3390/s21227754 es_ES
dc.relation.projectID info:eu-repo/grantAgreement/EC/H2020/814624/EU es_ES
dc.rights.accessRights Abierto es_ES
dc.contributor.affiliation Universitat Politècnica de València. Departamento de Física Aplicada - Departament de Física Aplicada es_ES
dc.contributor.affiliation Universitat Politècnica de València. Departamento de Informática de Sistemas y Computadores - Departament d'Informàtica de Sistemes i Computadors es_ES
dc.contributor.affiliation Universitat Politècnica de València. Departamento de Estadística e Investigación Operativa Aplicadas y Calidad - Departament d'Estadística i Investigació Operativa Aplicades i Qualitat es_ES
dc.description.bibliographicCitation Díaz-Arellano, I.; Zarzo Castelló, M.; García Diego, FJ.; Perles, A. (2021). A Methodology for the Multi-Point Characterization of Short-Term Temperature Fluctuations in Complex Microclimates Based on the European Standard EN 15757:2010: Application to the Archaeological Museum of L'Almoina (Valencia, Spain). Sensors. 21(22):1-20. https://doi.org/10.3390/s21227754 es_ES
dc.description.accrualMethod S es_ES
dc.relation.publisherversion https://doi.org/10.3390/s21227754 es_ES
dc.description.upvformatpinicio 1 es_ES
dc.description.upvformatpfin 20 es_ES
dc.type.version info:eu-repo/semantics/publishedVersion es_ES
dc.description.volume 21 es_ES
dc.description.issue 22 es_ES
dc.identifier.eissn 1424-8220 es_ES
dc.identifier.pmid 34833831 es_ES
dc.identifier.pmcid PMC8619385 es_ES
dc.relation.pasarela S\450515 es_ES
dc.contributor.funder COMISION DE LAS COMUNIDADES EUROPEA es_ES
upv.costeAPC 1900 es_ES


Este ítem aparece en la(s) siguiente(s) colección(ones)