Estudio de la eficiencia de un detector de Germanio mediante simulación Monte Carlo

RiuNet: Repositorio Institucional de la Universidad Politécnica de Valencia

Compartir/Enviar a

Citas

Estadísticas

  • Estadisticas de Uso

Estudio de la eficiencia de un detector de Germanio mediante simulación Monte Carlo

Mostrar el registro sencillo del ítem

Ficheros en el ítem

dc.contributor.advisor Juste Vidal, Belen Jeanne es_ES
dc.contributor.advisor Miró Herrero, Rafael es_ES
dc.contributor.author Navarro Gamón, Empar es_ES
dc.date.accessioned 2022-11-02T15:02:12Z
dc.date.available 2022-11-02T15:02:12Z
dc.date.created 2022-09-09
dc.date.issued 2022-11-02 es_ES
dc.identifier.uri http://hdl.handle.net/10251/189025
dc.description.abstract [ES] La protección radiológica del público y del medio ambiente tiene por objeto controlar el riesgo debido a la presencia de radiactividad en el medio ambiente, tanto de origen natural como derivada de la operación de las instalaciones nucleares y radiactivas. Un espectrómetro gamma que incluye un detector HPGe se utiliza comúnmente para mediciones de radiactividad ambiental y su uso se ha convertido en una práctica común en la mayoría de los laboratorios científicos modernos. Estos detectores a menudo necesitan ser calibrados y caracterizados para diferentes geometrías de fuentes de rayos gamma, energías y distancias de fuente a detector. El uso de simulaciones basadas en Monte Carlo permite realizar estas caracterizaciones en ausencia de material radiactivo y para configuraciones experimentales arbitrarias. En este trabajo se realiza el estudio de la utilidad de los códigos basados en Monte Carlo para modelar las eficiencias de los detectores de germanio. Para ello, se realiza el modelo de un detector coaxial HPGe con Monte Carlo utilizando el código MCNP6. Estas simulaciones permitirán el cálculo de la eficiencia máxima energética total para diferentes configuraciones de fuente en todo su rango energético. El modelo del detector se valida mediante la comparación de las curvas de eficiencia simuladas con valores experimentales medidos para fuentes puntuales y para un vaso de precipitados que contiene una fuente gamma certificada. es_ES
dc.description.abstract [EN] The radiological protection of citizens and environment has as an aim the control of the risk generated by the presence of radioactivity, for both natural and from the nuclear and radioactive facilities, in the milieu. A gamma spectrometer that includes the HPGe detector is commonly used to measure environmental radioactivity and its use has become a common practice in most of modern scientific laboratories. These detectors often need to be calibrated and characterised for different gamma rays source geometries, energies and distances between the source and the detector. The use of simulations based in Monte Carlo allow the implementation of these characterization in absence of radioactive material and for arbitrary experimental configurations. In this project is conducted the study of the utility of the codes based in Monte Carlo to mould the efficiencies of the germanium detector. To achieve it, the model of a coaxial HPGe detector will be carried out with Monte Carlo using the MCNP6 code. These simulations will allow the calculation of the total maximum energy efficiency for different source shaping in its whole energy range. The detector model is validated with the comparison of the efficiency curves simulated with the measured experimental values for point sources and for a beaker that contains a registered gamma source. es_ES
dc.format.extent 125 es_ES
dc.language Español es_ES
dc.publisher Universitat Politècnica de València es_ES
dc.rights Reserva de todos los derechos es_ES
dc.subject Detector gamma es_ES
dc.subject Germanio es_ES
dc.subject Eficiencia es_ES
dc.subject Monte Carlo es_ES
dc.subject MCNP es_ES
dc.subject.classification INGENIERIA NUCLEAR es_ES
dc.subject.other Grado en Ingeniería de la Energía-Grau en Enginyeria de l'Energia es_ES
dc.title Estudio de la eficiencia de un detector de Germanio mediante simulación Monte Carlo es_ES
dc.title.alternative Study of the efficiency of a Germanium detector with Monte Carlo s simulation es_ES
dc.title.alternative Estudi de la eficiència d un detector de Germani mitjançant simulació Monte Carlo es_ES
dc.type Proyecto/Trabajo fin de carrera/grado es_ES
dc.rights.accessRights Cerrado es_ES
dc.contributor.affiliation Universitat Politècnica de València. Departamento de Ingeniería Química y Nuclear - Departament d'Enginyeria Química i Nuclear es_ES
dc.contributor.affiliation Universitat Politècnica de València. Escuela Técnica Superior de Ingenieros Industriales - Escola Tècnica Superior d'Enginyers Industrials es_ES
dc.description.bibliographicCitation Navarro Gamón, E. (2022). Estudio de la eficiencia de un detector de Germanio mediante simulación Monte Carlo. Universitat Politècnica de València. http://hdl.handle.net/10251/189025 es_ES
dc.description.accrualMethod TFGM es_ES
dc.relation.pasarela TFGM\151337 es_ES


Este ítem aparece en la(s) siguiente(s) colección(ones)

Mostrar el registro sencillo del ítem