- -

Numerical Analysis of Ventricular Assist Devices Based on Centrifugal Turbopumps

RiuNet: Repositorio Institucional de la Universidad Politécnica de Valencia

Compartir/Enviar a

Citas

Estadísticas

  • Estadisticas de Uso

Numerical Analysis of Ventricular Assist Devices Based on Centrifugal Turbopumps

Mostrar el registro sencillo del ítem

Ficheros en el ítem

dc.contributor.advisor Gil Megías, Antonio es_ES
dc.contributor.author Mares Bou, Andrea es_ES
dc.date.accessioned 2022-11-07T08:51:00Z
dc.date.available 2022-11-07T08:51:00Z
dc.date.created 2022-09-29
dc.date.issued 2022-11-07 es_ES
dc.identifier.uri http://hdl.handle.net/10251/189213
dc.description.abstract [ES] Este Trabajo de Fin de Máster consiste en el análisis de la hemodinámica en el interior de Dispositivos de Asistencia Ventricular haciendo uso de la herramienta CFD. La última generación de dispositivos está compuesta por bombas centrífugas que utilizan sistemas de levitación magnética para posicionar el rotor asegurando una holgura entre partes móviles y estáticas. A pesar del uso en aumento de estos dispositivos como terapia de destino en pacientes en fases avanzadas de fallo cardíaco, todavía existen complicaciones en el largo plazo relacionadas con su hemocompatibilidad que hace referencia al daño a la sangre asociado a dispositivos médicos con superficies en contacto con la sangre. En este proyecto, se investigan las prestaciones de los principales dispositivos de la última generación considerando tanto la hemodinámica (salto de presión, potencia mecánica en el eje, eficiencia hidráulica) como el daño a la sangre asociado (hemólisis). Dichos dispositivos son HeartWare (HVAD) y HeartMate3 (HM3). El primero utiliza un sistema híbrido para el posicionamiento axial del rotor que combina levitación hidrodinámica y magnética. Como consecuencia de los requerimientos para la levitación hidrodinámica, incorpora un rotor de álabes anchos con gran superficie en contacto con la holgura axial que, además, tiene una altura del orden de diez glóbulos rojos. El segundo, en cambio, utiliza un sistema de levitación puramente magnético, hace uso de álabes convencionales y sus holguras tanto axiales como radiales son del orden de cien glóbulos rojos. Los modelos CFD de ambos dispositivos se validan experimentalmente, y se comparan diversas metodologías computacionales con el fin de construir el modelo más apropiado. Los diferentes diseños de los dispositivos considerados conllevan a prestaciones notablemente desiguales: HM3 presenta mayor eficiencia hidráulica y tiene asociado un daño a la sangre menor que HVAD, debido a la forma de sus álabes y al diseño de las holguras es_ES
dc.description.abstract [EN] This Final Year Project consists in the analysis of the hemodynamics within Left Ventricular Assist Devices using Computational Fluid Dynamics (CFD). The last generation of devices is composed of centrifugal turbopumps which employ magnetic levitation bearings to position the impeller ensuring a gap distance between moving and static parts. Despite the increasing use of these devices as a destination therapy in patients suffering from advanced heart failure, several long-term complications still exist regarding their hemocompatibility which refers to the blood damage associated to blood-contacting medical devices. In this project, the performance of the main devices of the last generation is investigated considering both the hemodynamic performance (pressure head, mechanical shaft power, hydraulic efficiency) and the associated blood damage (hemolysis). These devices are HeartWare (HVAD) and HeartMate3 (HM3). The former employs a hybrid system to position the impeller axially by combining hydrodynamic and magnetic levitation. As a consequence of the hydrodynamic lift¿s requirements, it incorporates a wide-blade impeller with large areas in contact with the axial gap which has a clearance of the order of ten red blood cells. The latter, conversely, employs a uniquely magnetic levitation system, incorporates conventional blades and its axial and radial gaps have clearances of the order of hundred red blood cells. The CFD models for both devices are validated experimentally, and several computational methodologies are compared in order to construct the more appropriate model. The different designs of the considered devices lead to dissimilar performance: HM3 presents higher hydraulic efficiency and reduced blood damage in comparison with HVAD, due to the shape of its blades and the gap design. es_ES
dc.format.extent 33 es_ES
dc.language Inglés es_ES
dc.publisher Universitat Politècnica de València es_ES
dc.rights Reserva de todos los derechos es_ES
dc.subject Mecánica de fluidos computacional (CFD) es_ES
dc.subject Prestaciones hemodinámicas es_ES
dc.subject Eficiencia hidráulica es_ES
dc.subject Hemocompatibilidad es_ES
dc.subject Hemólisis es_ES
dc.subject Bombas centrífugas es_ES
dc.subject Holgura es_ES
dc.subject Álabes es_ES
dc.subject Hemodynamic performance es_ES
dc.subject Hydraulic efficiency es_ES
dc.subject Hemocompatibility es_ES
dc.subject Hemolysis es_ES
dc.subject Computational Fluid Dynamics es_ES
dc.subject Centrifugal pumps es_ES
dc.subject Gap clearance es_ES
dc.subject Blades es_ES
dc.subject.classification MAQUINAS Y MOTORES TERMICOS es_ES
dc.subject.other Máster Universitario en Motores de Combustión Interna Alternativos-Màster Universitari en Motors de Combustió Interna Alternatius es_ES
dc.title Numerical Analysis of Ventricular Assist Devices Based on Centrifugal Turbopumps es_ES
dc.title.alternative Análisis numérico de dispositivos de asistencia ventricular basados en turbobombas centrífugas es_ES
dc.title.alternative Anàlisi numèrica de dispositius d'assistència ventricular basats en turbobombes centrífugues es_ES
dc.type Tesis de máster es_ES
dc.rights.accessRights Cerrado es_ES
dc.contributor.affiliation Universitat Politècnica de València. Departamento de Máquinas y Motores Térmicos - Departament de Màquines i Motors Tèrmics es_ES
dc.description.bibliographicCitation Mares Bou, A. (2022). Numerical Analysis of Ventricular Assist Devices Based on Centrifugal Turbopumps. Universitat Politècnica de València. http://hdl.handle.net/10251/189213 es_ES
dc.description.accrualMethod TFGM es_ES
dc.relation.pasarela TFGM\149414 es_ES


Este ítem aparece en la(s) siguiente(s) colección(ones)

Mostrar el registro sencillo del ítem