Comparative evaluation of two photovoltaic multi-pump parallel system configurations for optimal distribution of the generated power

RiuNet: Repositorio Institucional de la Universidad Politécnica de Valencia

Compartir/Enviar a

Citas

Estadísticas

  • Estadisticas de Uso

Comparative evaluation of two photovoltaic multi-pump parallel system configurations for optimal distribution of the generated power

Mostrar el registro sencillo del ítem

Ficheros en el ítem

dc.contributor.author Gasque Albalate, Maria es_ES
dc.contributor.author González Altozano, Pablo es_ES
dc.contributor.author Gutiérrez-Colomer, Rosa Penélope es_ES
dc.contributor.author García-Marí, Eugenio es_ES
dc.date.accessioned 2022-11-07T16:34:07Z
dc.date.available 2022-11-07T16:34:07Z
dc.date.issued 2021-12 es_ES
dc.identifier.issn 2213-1388 es_ES
dc.identifier.uri http://hdl.handle.net/10251/189334
dc.description.abstract [EN] The suitability of a strategy for distributing the power generated by a photovoltaic pumping system equipped with two equal pumps working in parallel is proven. This strategy aims to improve energy management and consists of feeding a single pump with all the power generated until it exceeds a threshold value from which the power distribution must be at 50% between the two pumps. This pumping method was compared with the operation mode usually applied in parallel PV pumping facilities (50% of the power always assigned to each pump). A system equipped with two 0.75 kW pumps was employed. The assessment of the facility's performance under the two alternative working conditions and several pumping heads was conducted using simulation techniques. Both the pumped annual volume and the annual efficiency of the motor-pump group increased when the strategy was applied compared to operation with power distribution at 50%. This increase was greater the higher the head (6.21% at H = 18 m vs. 57.60% at H = 48 m for pumped annual volume and 6.42% at H = 18 m vs. 57.51% at H = 48 m for annual efficiency). The halving of the irradiance threshold and the improved efficiency (36.4% vs. 34.8%) may explain this increase. es_ES
dc.language Inglés es_ES
dc.publisher Elsevier es_ES
dc.relation.ispartof Sustainable Energy Technologies and Assessments es_ES
dc.rights Reconocimiento (by) es_ES
dc.subject Pumping system es_ES
dc.subject Energy optimisation es_ES
dc.subject Parallel pumps es_ES
dc.subject System performance es_ES
dc.subject Simulation es_ES
dc.title Comparative evaluation of two photovoltaic multi-pump parallel system configurations for optimal distribution of the generated power es_ES
dc.type Artículo es_ES
dc.identifier.doi 10.1016/j.seta.2021.101634 es_ES
dc.rights.accessRights Abierto es_ES
dc.description.bibliographicCitation Gasque Albalate, M.; González Altozano, P.; Gutiérrez-Colomer, RP.; García-Marí, E. (2021). Comparative evaluation of two photovoltaic multi-pump parallel system configurations for optimal distribution of the generated power. Sustainable Energy Technologies and Assessments. 48:1-11. https://doi.org/10.1016/j.seta.2021.101634 es_ES
dc.description.accrualMethod S es_ES
dc.relation.publisherversion https://doi.org/10.1016/j.seta.2021.101634 es_ES
dc.description.upvformatpinicio 1 es_ES
dc.description.upvformatpfin 11 es_ES
dc.type.version info:eu-repo/semantics/publishedVersion es_ES
dc.description.volume 48 es_ES
dc.relation.pasarela S\453400 es_ES
dc.subject.ods 02.- Poner fin al hambre, conseguir la seguridad alimentaria y una mejor nutrición, y promover la agricultura sostenible es_ES
dc.subject.ods 06.- Garantizar la disponibilidad y la gestión sostenible del agua y el saneamiento para todos es_ES
dc.subject.ods 07.- Asegurar el acceso a energías asequibles, fiables, sostenibles y modernas para todos es_ES
dc.subject.ods 12.- Garantizar las pautas de consumo y de producción sostenibles es_ES


Este ítem aparece en la(s) siguiente(s) colección(ones)

Mostrar el registro sencillo del ítem