- -

Radiofrequency Ablation Using a Novel Insulated-Tip Ablation Catheter Can Create Uniform Lesions Comparable in Size to Conventional Irrigated Ablation Catheters While Using a Fraction of the Energy and Irrigation

RiuNet: Repositorio Institucional de la Universidad Politécnica de Valencia

Compartir/Enviar a

Citas

Estadísticas

  • Estadisticas de Uso

Radiofrequency Ablation Using a Novel Insulated-Tip Ablation Catheter Can Create Uniform Lesions Comparable in Size to Conventional Irrigated Ablation Catheters While Using a Fraction of the Energy and Irrigation

Mostrar el registro completo del ítem

Aryana, A.; Irastorza, RM.; Berjano, E.; Cohen, RJ.; Kraus, J.; Haghighi-Mood, A.; Reddy, VY.... (2022). Radiofrequency Ablation Using a Novel Insulated-Tip Ablation Catheter Can Create Uniform Lesions Comparable in Size to Conventional Irrigated Ablation Catheters While Using a Fraction of the Energy and Irrigation. Journal of Cardiovascular Electrophysiology. 33(6):1146-1156. https://doi.org/10.1111/jce.15461

Por favor, use este identificador para citar o enlazar este ítem: http://hdl.handle.net/10251/190343

Ficheros en el ítem

Metadatos del ítem

Título: Radiofrequency Ablation Using a Novel Insulated-Tip Ablation Catheter Can Create Uniform Lesions Comparable in Size to Conventional Irrigated Ablation Catheters While Using a Fraction of the Energy and Irrigation
Autor: Aryana, Arash Irastorza, Ramiro M. Berjano, Enrique Cohen, Richard J. Kraus, Jeffrey Haghighi-Mood, Ali Reddy, Vivek Y. D Avila, Andre
Entidad UPV: Universitat Politècnica de València. Escuela Técnica Superior de Ingeniería del Diseño - Escola Tècnica Superior d'Enginyeria del Disseny
Fecha difusión:
Resumen:
[EN] Introduction: During radiofrequency ablation (RFA) using conventional RFA catheters (RFC), similar to 90% of the energy dissipates into the bloodstream/surrounding tissue. We hypothesized that a novel insulated-tip ...[+]
Palabras clave: Catheter ablation , Power , Radiofrequency , SMT , Steam pop
Derechos de uso: Reconocimiento - No comercial (by-nc)
Fuente:
Journal of Cardiovascular Electrophysiology. (issn: 1045-3873 )
DOI: 10.1111/jce.15461
Editorial:
Blackwell Publishing
Versión del editor: https://doi.org/10.1111/jce.15461
Código del Proyecto:
info:eu-repo/grantAgreement/AEI/Plan Estatal de Investigación Científica y Técnica y de Innovación 2017-2020/RTI2018-094357-B-C21/ES/MODELADO Y EXPERIMENTACION PARA TERAPIAS ABLATIVAS INNOVADORAS/
info:eu-repo/grantAgreement/Universidad Nacional Arturo Jauretche, Argentina//80020170100019UJ/
Agradecimientos:
Sirona Medical Technologies, Inc; The Proyecto UNAJ Investiga 2017, Grant/Award Number: 80020170100019UJ; The Spanish Ministerio de Ciencia, Innovacion y Universidades/Agencia Estatal de Investigacion (MCIN/AEI/10.13039/ ...[+]
Tipo: Artículo

recommendations

 

Este ítem aparece en la(s) siguiente(s) colección(ones)

Mostrar el registro completo del ítem