Mostrar el registro sencillo del ítem
dc.contributor.author | Torralba, Alberto | es_ES |
dc.contributor.author | Palenciano-Castro, Lidia | es_ES |
dc.contributor.author | Reija, Alicia | es_ES |
dc.contributor.author | Rigla, Juan Pablo | es_ES |
dc.contributor.author | Peñas, Juan | es_ES |
dc.contributor.author | Llerena, Juan José | es_ES |
dc.contributor.author | Contreras-Martinez, Ramiro | es_ES |
dc.contributor.author | Benlliure, José | es_ES |
dc.contributor.author | Vega, Ana | es_ES |
dc.contributor.author | Aguado-Barrera, Miguel Elías | es_ES |
dc.contributor.author | Ruiz, Camilo | es_ES |
dc.contributor.author | Seimetz, Michael | es_ES |
dc.date.accessioned | 2022-11-30T19:01:48Z | |
dc.date.available | 2022-11-30T19:01:48Z | |
dc.date.issued | 2022-03 | es_ES |
dc.identifier.uri | http://hdl.handle.net/10251/190415 | |
dc.description.abstract | [EN] Laser-plasma proton sources and their applications to preclinical research has become a very active field of research in recent years. In addition to their small dimensions as compared to classical ion accelerators, they offer the possibility to study the biological effects of ultra-short particle bunches and the correspondingly high dose rates. We report on the design of an experimental setup for the irradiation of cell cultures at the L2A2 laboratory at the University of Santiago de Compostela, making use of a 1.2 J Ti: Sapphire laser with a 10 Hz repetition rate. Our setup comprises a proton energy separator consisting of two antiparallel magnetic fields realized by a set of permanent magnets. It allows for selecting a narrow energy window around an adaptable design value of 5 MeV out of the initially broad spectrum typical for Target Normal Sheath Acceleration (TNSA). At the same time, unwanted electrons and X-rays are segregated from the protons. This part of the setup is located inside the target vessel of the L2A2 laser. A subsequent vacuum flange sealed with a thin kapton window allows for particle passage to external sample irradiation. A combination of passive detector materials and real-time monitors is applied for measurement of the deposited radiation dose. A critical point of this interdisciplinary project is the manipulation of biological samples under well-controlled, sterile conditions. Cell cultures are prepared in sealed flasks with an ultra-thin entrance window and analysed at the nearby Fundacion Publica Galega Medicina Xenomica and IDIS. The first trials will be centred at the quantification of DNA double-strand breaks as a function of radiation dose. | es_ES |
dc.description.sponsorship | Projects RTI2018-101578-B-C21 and RTI2018-101578-B-C22 are funded by MCIN/AEI /10.13039/501100011033 and by FEDER "Una manera de hacer Europa". Project AICO/2020/207 is funded by Generalitat Valenciana. Supports PEJ2018-002035-A and PEJ2018-002037-A are financed by AEI and "El FSE invierte en tu futuro". Additional funding is by FPI predoctoral grant BES-2017-08917 and Unidad de Excelencia Maria de Maeztu, MdM-2016-0692-17-2. Action is co-financed by the European Union through the Programa Operativo del Fondo Europeo de Desarrollo Regional (FEDER) of the Comunitat Valenciana 2014-2020 (IDIFEDER/2018/022 and IDIFEDER/2021/004). FPGMX-IDIS research is partially supported by the Spanish Instituto de Salud Carlos III (ISCIII) funding, which is an initiative of the Spanish Ministry of Economy and Innovation partially supported by European Regional Development FEDER Funds (INT20/00071, PI19/01424, AC18/00117) and through the Autonomous Government of Galicia (Consolidation and structuring program: IN607B) given to A. Vega. | es_ES |
dc.language | Inglés | es_ES |
dc.publisher | MDPI AG | es_ES |
dc.relation.ispartof | Quantum Beam Science | es_ES |
dc.rights | Reconocimiento (by) | es_ES |
dc.subject | Laser-plasma interaction | es_ES |
dc.subject | TNSA | es_ES |
dc.subject | In vitro irradiation | es_ES |
dc.subject | Dose measurement | es_ES |
dc.title | Experimental Setup for Irradiation of Cell Cultures at L2A2 | es_ES |
dc.type | Artículo | es_ES |
dc.identifier.doi | 10.3390/qubs6010010 | es_ES |
dc.relation.projectID | info:eu-repo/grantAgreement/AEI/Plan Estatal de Investigación Científica y Técnica y de Innovación 2017-2020/RTI2018-101578-B-C21/ES/APLICACIONES MEDICAS DE LOS ACELERADORES LASER/ | es_ES |
dc.relation.projectID | info:eu-repo/grantAgreement/Xunta de Galicia//IN607B/ | es_ES |
dc.relation.projectID | info:eu-repo/grantAgreement/AEI/Plan Estatal de Investigación Científica y Técnica y de Innovación 2017-2020/RTI2018-101578-B-C22/ES/EFECTOS RADIOBIOLOGICOS DE PULSOS DE PARTICULAS ULTRA-INTENSOS EN CELULAS VIVAS/ | es_ES |
dc.relation.projectID | info:eu-repo/grantAgreement/GVA//AICO%2F2020%2F207/ | es_ES |
dc.relation.projectID | info:eu-repo/grantAgreement/GVA//IDIFEDER%2F2018%2F022//EQUIPOS PARA TECNICAS MIXTAS ELECTROMAGNETICAS-ULTRASONICAS PARA IMAGEN MEDICA/ | es_ES |
dc.relation.projectID | info:eu-repo/grantAgreement/GVA//IDIFEDER%2F2021%2F004/ | es_ES |
dc.relation.projectID | info:eu-repo/grantAgreement/MCIU//MDM-2016-0692//Programa Maria de Maetzu/ | es_ES |
dc.relation.projectID | info:eu-repo/grantAgreement/MINECO//INT20%2F00071/ | es_ES |
dc.relation.projectID | info:eu-repo/grantAgreement/MINECO//PI19%2F01424/ | es_ES |
dc.relation.projectID | info:eu-repo/grantAgreement/MINECO//AC18%2F00117/ | es_ES |
dc.relation.projectID | info:eu-repo/grantAgreement/AEI//PEJ2018-002035-A/ | es_ES |
dc.relation.projectID | info:eu-repo/grantAgreement/AEI//PEJ2018-002037-A/ | es_ES |
dc.relation.projectID | info:eu-repo/grantAgreement/MICINN//BES-2017-08917/ | es_ES |
dc.rights.accessRights | Abierto | es_ES |
dc.contributor.affiliation | Universitat Politècnica de València. Instituto de Instrumentación para Imagen Molecular - Institut d'Instrumentació per a Imatge Molecular | es_ES |
dc.description.bibliographicCitation | Torralba, A.; Palenciano-Castro, L.; Reija, A.; Rigla, JP.; Peñas, J.; Llerena, JJ.; Contreras-Martinez, R.... (2022). Experimental Setup for Irradiation of Cell Cultures at L2A2. Quantum Beam Science. 6(1):1-11. https://doi.org/10.3390/qubs6010010 | es_ES |
dc.description.accrualMethod | S | es_ES |
dc.relation.publisherversion | https://doi.org/10.3390/qubs6010010 | es_ES |
dc.description.upvformatpinicio | 1 | es_ES |
dc.description.upvformatpfin | 11 | es_ES |
dc.type.version | info:eu-repo/semantics/publishedVersion | es_ES |
dc.description.volume | 6 | es_ES |
dc.description.issue | 1 | es_ES |
dc.identifier.eissn | 2412-382X | es_ES |
dc.relation.pasarela | S\456709 | es_ES |
dc.contributor.funder | Xunta de Galicia | es_ES |
dc.contributor.funder | Generalitat Valenciana | es_ES |
dc.contributor.funder | Instituto de Salud Carlos III | es_ES |
dc.contributor.funder | Agencia Estatal de Investigación | es_ES |
dc.contributor.funder | European Regional Development Fund | es_ES |
dc.contributor.funder | Ministerio de Ciencia e Innovación | es_ES |
dc.contributor.funder | Ministerio de Economía y Competitividad | es_ES |
dc.contributor.funder | Ministerio de Ciencia, Innovación y Universidades | es_ES |