dc.contributor.author | Vraka, Aikaterini | es_ES |
dc.contributor.author | Bertomeu-González, Vicente | es_ES |
dc.contributor.author | Hornero, Fernando | es_ES |
dc.contributor.author | Sörnmo, Leif | es_ES |
dc.contributor.author | Alcaraz, Raúl | es_ES |
dc.contributor.author | Rieta, J J | es_ES |
dc.date.accessioned | 2022-12-16T08:09:13Z | |
dc.date.available | 2022-12-16T08:09:13Z | |
dc.date.issued | 2021-11-19 | es_ES |
dc.identifier.isbn | 978-1-6654-4000-4 | es_ES |
dc.identifier.issn | 2575-5145 | es_ES |
dc.identifier.uri | http://hdl.handle.net/10251/190758 | |
dc.description.abstract | [EN] While P-wave duration (PWD) is primarily employed to observe the atrial substrate alterations after pulmonary vein isolation (PVI) on atrial fibrillation (AF) patients, the acquired information corresponds to the entire atria. Left (LA) and right atrium (RA), though, may be differently affected by PVI, implying the need for different after-PVI handling. In order to clarify this assumption, five-minute lead II recordings from 29 paroxysmal AF patients undergoing first-ever PVI were recruited before and after PVI. PWD was analyzed integrally and in parts, with the first part (PWD1) from the onset to the peak corresponding to RA and the second part (PWD2) to LA depolarization. Time from P-wave onset or offset to the R peak were also calculated (P-on - R and P-off - R, respectively). Normalization (N) to mitigate heart-rate effect was applied. Results before and after PVI were compared with Mann-Whitney U-test (MWU). Median values and variations due to PVI were calculated for all features and compared between PWD and the remaining features via Pearson correlation. After PVI, PWD (-9.84%, p = 0.0085, N : -17.96%, p = 0.0442) and PWD2 (-22.03% p = 0.0250, N : -27.77%; p = 0.0268) were significantly decreased. PWD1 did not shorten significantly (up to -8.96%, p > 0.05 at either cases). PWD - PWD1 (rho > 74.5%; p < 0.0001) showed higher correlation than PWD - PWD2 (rho > 41.9%; p < 0.0001) in before and after PVI analysis but not for PVI-related variation (rho(PWD - PWD1) = 54.0%; p = 0.0114 and rho(PWD - PWD2) = 61.4%; p = 0.0031). While RA depolarization time is more in line with PWD analysis, the effect of PVI in PWD is more coherent with LA's findings. Additionally, PWD shortening is only observed in the LA. Therefore, LA is crucial for the assessment of the atrial substrate alteration after PVI and its analysis should be considered by future studies. | es_ES |
dc.description.sponsorship | Research supported by grants DPI2017-83952-C3 from MINECO/AEI/FEDER UE, SBPLY/17/180501/000411 from JCCLM and AICO/2021/286 from GVA. | es_ES |
dc.language | Inglés | es_ES |
dc.publisher | IEEE | es_ES |
dc.relation.ispartof | Proceedings of the 9th IEEE International Conference on E-Health and Bioengineering - EHB 2021 | es_ES |
dc.rights | Reserva de todos los derechos | es_ES |
dc.subject | Atrial fibrillation | es_ES |
dc.subject | Pulmonary vein isolation | es_ES |
dc.subject | P-wave | es_ES |
dc.subject | Left atrium | es_ES |
dc.subject | Partial analysis | es_ES |
dc.subject.classification | TECNOLOGIA ELECTRONICA | es_ES |
dc.title | Alternative Time-Domain P-wave Analysis for Precise Information on Substrate Alteration After Pulmonary Vein Isolation for Atrial Fibrillation | es_ES |
dc.type | Comunicación en congreso | es_ES |
dc.type | Artículo | es_ES |
dc.type | Capítulo de libro | es_ES |
dc.identifier.doi | 10.1109/EHB52898.2021.9657541 | es_ES |
dc.relation.projectID | info:eu-repo/grantAgreement/AEI/Plan Estatal de Investigación Científica y Técnica y de Innovación 2013-2016/DPI2017-83952-C3-1-R/ES/ESTUDIO MULTICENTRICO PARA LA EVALUACION DEL SUSTRATO ARRITMOGENICO EN PACIENTES CON FIBRILACION AURICULAR. APLICACION A LA ABLACION POR CATETER/ | es_ES |
dc.relation.projectID | info:eu-repo/grantAgreement///AICO%2F2021%2F286//Inteligencia Artificial para Revolucionar la Medicina Móvil Usando Dispositivos Llevables/ | es_ES |
dc.relation.projectID | info:eu-repo/grantAgreement/JCCM//SBPLY%2F17%2F180501%2F000411//Caracterización del sustrato auricular mediante análisis de señal como herramienta de asistencia procedimental en ablación por catéter de fibrilación auricular/ | es_ES |
dc.rights.accessRights | Abierto | es_ES |
dc.contributor.affiliation | Universitat Politècnica de València. Departamento de Ingeniería Electrónica - Departament d'Enginyeria Electrònica | es_ES |
dc.contributor.affiliation | Universitat Politècnica de València. Escuela Politécnica Superior de Gandia - Escola Politècnica Superior de Gandia | es_ES |
dc.description.bibliographicCitation | Vraka, A.; Bertomeu-González, V.; Hornero, F.; Sörnmo, L.; Alcaraz, R.; Rieta, JJ. (2021). Alternative Time-Domain P-wave Analysis for Precise Information on Substrate Alteration After Pulmonary Vein Isolation for Atrial Fibrillation. IEEE. 1-4. https://doi.org/10.1109/EHB52898.2021.9657541 | es_ES |
dc.description.accrualMethod | S | es_ES |
dc.relation.conferencename | 9th IEEE International Conference on e-Health and Bioengineering (EHB 2021) | es_ES |
dc.relation.conferencedate | Noviembre 18-19,2021 | es_ES |
dc.relation.conferenceplace | Online | es_ES |
dc.relation.publisherversion | https://doi.org/10.1109/EHB52898.2021.9657541 | es_ES |
dc.description.upvformatpinicio | 1 | es_ES |
dc.description.upvformatpfin | 4 | es_ES |
dc.type.version | info:eu-repo/semantics/publishedVersion | es_ES |
dc.relation.pasarela | S\463404 | es_ES |
dc.contributor.funder | European Regional Development Fund | es_ES |
dc.contributor.funder | Junta de Comunidades de Castilla-La Mancha | es_ES |