- -

Alternative Time-Domain P-wave Analysis for Precise Information on Substrate Alteration After Pulmonary Vein Isolation for Atrial Fibrillation

RiuNet: Repositorio Institucional de la Universidad Politécnica de Valencia

Compartir/Enviar a

Citas

Estadísticas

  • Estadisticas de Uso

Alternative Time-Domain P-wave Analysis for Precise Information on Substrate Alteration After Pulmonary Vein Isolation for Atrial Fibrillation

Mostrar el registro sencillo del ítem

Ficheros en el ítem

dc.contributor.author Vraka, Aikaterini es_ES
dc.contributor.author Bertomeu-González, Vicente es_ES
dc.contributor.author Hornero, Fernando es_ES
dc.contributor.author Sörnmo, Leif es_ES
dc.contributor.author Alcaraz, Raúl es_ES
dc.contributor.author Rieta, J J es_ES
dc.date.accessioned 2022-12-16T08:09:13Z
dc.date.available 2022-12-16T08:09:13Z
dc.date.issued 2021-11-19 es_ES
dc.identifier.isbn 978-1-6654-4000-4 es_ES
dc.identifier.issn 2575-5145 es_ES
dc.identifier.uri http://hdl.handle.net/10251/190758
dc.description.abstract [EN] While P-wave duration (PWD) is primarily employed to observe the atrial substrate alterations after pulmonary vein isolation (PVI) on atrial fibrillation (AF) patients, the acquired information corresponds to the entire atria. Left (LA) and right atrium (RA), though, may be differently affected by PVI, implying the need for different after-PVI handling. In order to clarify this assumption, five-minute lead II recordings from 29 paroxysmal AF patients undergoing first-ever PVI were recruited before and after PVI. PWD was analyzed integrally and in parts, with the first part (PWD1) from the onset to the peak corresponding to RA and the second part (PWD2) to LA depolarization. Time from P-wave onset or offset to the R peak were also calculated (P-on - R and P-off - R, respectively). Normalization (N) to mitigate heart-rate effect was applied. Results before and after PVI were compared with Mann-Whitney U-test (MWU). Median values and variations due to PVI were calculated for all features and compared between PWD and the remaining features via Pearson correlation. After PVI, PWD (-9.84%, p = 0.0085, N : -17.96%, p = 0.0442) and PWD2 (-22.03% p = 0.0250, N : -27.77%; p = 0.0268) were significantly decreased. PWD1 did not shorten significantly (up to -8.96%, p > 0.05 at either cases). PWD - PWD1 (rho > 74.5%; p < 0.0001) showed higher correlation than PWD - PWD2 (rho > 41.9%; p < 0.0001) in before and after PVI analysis but not for PVI-related variation (rho(PWD - PWD1) = 54.0%; p = 0.0114 and rho(PWD - PWD2) = 61.4%; p = 0.0031). While RA depolarization time is more in line with PWD analysis, the effect of PVI in PWD is more coherent with LA's findings. Additionally, PWD shortening is only observed in the LA. Therefore, LA is crucial for the assessment of the atrial substrate alteration after PVI and its analysis should be considered by future studies. es_ES
dc.description.sponsorship Research supported by grants DPI2017-83952-C3 from MINECO/AEI/FEDER UE, SBPLY/17/180501/000411 from JCCLM and AICO/2021/286 from GVA. es_ES
dc.language Inglés es_ES
dc.publisher IEEE es_ES
dc.relation.ispartof Proceedings of the 9th IEEE International Conference on E-Health and Bioengineering - EHB 2021 es_ES
dc.rights Reserva de todos los derechos es_ES
dc.subject Atrial fibrillation es_ES
dc.subject Pulmonary vein isolation es_ES
dc.subject P-wave es_ES
dc.subject Left atrium es_ES
dc.subject Partial analysis es_ES
dc.subject.classification TECNOLOGIA ELECTRONICA es_ES
dc.title Alternative Time-Domain P-wave Analysis for Precise Information on Substrate Alteration After Pulmonary Vein Isolation for Atrial Fibrillation es_ES
dc.type Comunicación en congreso es_ES
dc.type Artículo es_ES
dc.type Capítulo de libro es_ES
dc.identifier.doi 10.1109/EHB52898.2021.9657541 es_ES
dc.relation.projectID info:eu-repo/grantAgreement/AEI/Plan Estatal de Investigación Científica y Técnica y de Innovación 2013-2016/DPI2017-83952-C3-1-R/ES/ESTUDIO MULTICENTRICO PARA LA EVALUACION DEL SUSTRATO ARRITMOGENICO EN PACIENTES CON FIBRILACION AURICULAR. APLICACION A LA ABLACION POR CATETER/ es_ES
dc.relation.projectID info:eu-repo/grantAgreement///AICO%2F2021%2F286//Inteligencia Artificial para Revolucionar la Medicina Móvil Usando Dispositivos Llevables/ es_ES
dc.relation.projectID info:eu-repo/grantAgreement/JCCM//SBPLY%2F17%2F180501%2F000411//Caracterización del sustrato auricular mediante análisis de señal como herramienta de asistencia procedimental en ablación por catéter de fibrilación auricular/ es_ES
dc.rights.accessRights Abierto es_ES
dc.contributor.affiliation Universitat Politècnica de València. Departamento de Ingeniería Electrónica - Departament d'Enginyeria Electrònica es_ES
dc.contributor.affiliation Universitat Politècnica de València. Escuela Politécnica Superior de Gandia - Escola Politècnica Superior de Gandia es_ES
dc.description.bibliographicCitation Vraka, A.; Bertomeu-González, V.; Hornero, F.; Sörnmo, L.; Alcaraz, R.; Rieta, JJ. (2021). Alternative Time-Domain P-wave Analysis for Precise Information on Substrate Alteration After Pulmonary Vein Isolation for Atrial Fibrillation. IEEE. 1-4. https://doi.org/10.1109/EHB52898.2021.9657541 es_ES
dc.description.accrualMethod S es_ES
dc.relation.conferencename 9th IEEE International Conference on e-Health and Bioengineering (EHB 2021) es_ES
dc.relation.conferencedate Noviembre 18-19,2021 es_ES
dc.relation.conferenceplace Online es_ES
dc.relation.publisherversion https://doi.org/10.1109/EHB52898.2021.9657541 es_ES
dc.description.upvformatpinicio 1 es_ES
dc.description.upvformatpfin 4 es_ES
dc.type.version info:eu-repo/semantics/publishedVersion es_ES
dc.relation.pasarela S\463404 es_ES
dc.contributor.funder European Regional Development Fund es_ES
dc.contributor.funder Junta de Comunidades de Castilla-La Mancha es_ES


Este ítem aparece en la(s) siguiente(s) colección(ones)

Mostrar el registro sencillo del ítem