- -

Uterine slow wave: directionality and changes with imminent delivery

RiuNet: Repositorio Institucional de la Universidad Politécnica de Valencia

Compartir/Enviar a

Citas

Estadísticas

  • Estadisticas de Uso

Uterine slow wave: directionality and changes with imminent delivery

Mostrar el registro sencillo del ítem

Ficheros en el ítem

dc.contributor.author Albaladejo-Belmonte, Mónica es_ES
dc.contributor.author Prats-Boluda, Gema es_ES
dc.contributor.author Ye Lin, Yiyao es_ES
dc.contributor.author Garfield, Robert E. es_ES
dc.contributor.author Garcia-Casado, Javier es_ES
dc.date.accessioned 2023-01-17T19:00:13Z
dc.date.available 2023-01-17T19:00:13Z
dc.date.issued 2022-08-19 es_ES
dc.identifier.issn 0967-3334 es_ES
dc.identifier.uri http://hdl.handle.net/10251/191384
dc.description.abstract [EN] Objective. The slow wave (SW) of the electrohysterogram (EHG) may contain relevant information on the electrophysiological condition of the uterus throughout pregnancy and labor. Our aim was to assess differences in the SW as regards the imminence of labor and the directionality of uterine myoelectrical activity. Approach. The SW of the EHGwas extracted from the signals of the Icelandic 16-electrode EHG database in the bandwidth [5, 30] mHz and its power, spectral content, complexity and synchronization between the horizontal (X) and vertical (Y) directions were characterized by the root mean square (RMS), dominant frequency (domF), sample entropy (SampEn) and maximum cross-correlation (CCmax) of the signals, respectively. Significant differences between parameters at time-to-delivery (TTD) <= 7 versus>7 days and between the horizontal versus vertical directions were assessed. Main results. The SW power significantly increased in both directions as labor approached (TTD <= 7d versus>7d (mean +/- SD): RMSx = 0.12 +/- 0.10 versus 0.08 +/- 0.06 mV; RMSy = 0.12 +/- 0.09 versus 0.08 +/- 0.05mV), as well as the dominant frequency in the horizontal direction (domF(x) = 9.1 +/- 1.3 versus 8.5 +/- 1.2mHz) and the synchronization between both directions (CCmax = 0.44 +/- 0.16 versus 0.36 +/- 0.14). Furthermore, its complexity decreased in the vertical direction (SampEn(y) = 6.13 center dot 10(-2) +/- 8.7 center dot 10(-3) versus 6.50 center dot 10(-2) +/- 8.3 center dot 10(-3)), suggesting a higher cell-to-cell electrical coupling. Whereas there were no differences between the SW features in both directions in the general population, statistically significant differences were obtained between them in individuals in many cases. Significance. Our results suggest that the SW of the EHG is related to bioelectrical events in the uterus and could provide objective information to clinicians in challenging obstetric scenarios. es_ES
dc.description.sponsorship This study was funded by Generalitat Valenciana in Programa para la promocion de I.+.D+i ACIF/2021/012, AICO/2021/126; the Spanish Ministry of Economy and Competitiveness, the European Regional Development Fund (MCIU/AEI/FEDER, UE RTI2018-094449-A-I00-AR). es_ES
dc.language Inglés es_ES
dc.publisher IOP Publishing es_ES
dc.relation.ispartof Physiological Measurement es_ES
dc.rights Reconocimiento - No comercial - Sin obra derivada (by-nc-nd) es_ES
dc.subject Electrohysterogram es_ES
dc.subject Slow wave es_ES
dc.subject Delivery es_ES
dc.subject Labor es_ES
dc.subject Directionality es_ES
dc.subject.classification TECNOLOGIA ELECTRONICA es_ES
dc.title Uterine slow wave: directionality and changes with imminent delivery es_ES
dc.type Artículo es_ES
dc.identifier.doi 10.1088/1361-6579/ac84c0 es_ES
dc.relation.projectID info:eu-repo/grantAgreement/AEI/Plan Estatal de Investigación Científica y Técnica y de Innovación 2017-2020/RTI2018-094449-A-I00/ES/ELECTROHISTEROGRAFIA PARA LA MEJORA EN LA TOMA DE DECISIONES EN SITUACIONES DE RIESGO EN OBSTETRICIA: PARTO PREMATURO E INDUCCION DEL PARTO/ es_ES
dc.relation.projectID info:eu-repo/grantAgreement/GENERALITAT VALENCIANA//AICO%2F2021%2F126//Desarrollo de herramientas de uso clínico basadas en electromiografía de superficie para el diagnóstico de la vulvodinia y seguimiento de su tratamiento con toxina botulínica/ es_ES
dc.relation.projectID info:eu-repo/grantAgreement/GENERALITAT VALENCIANA//ACIF%2F2021%2F012//CARACTERIZACION DE LA MUSCULATURA PELVIA, MEDIANTE ELECTROMIOGRAMA DE SUPERFICIE EN PACIENTES CON DOLOR PELVICO CRONICO Y DE LA EVOLUCION/ es_ES
dc.rights.accessRights Abierto es_ES
dc.contributor.affiliation Universitat Politècnica de València. Escuela Técnica Superior de Ingenieros Industriales - Escola Tècnica Superior d'Enginyers Industrials es_ES
dc.contributor.affiliation Universitat Politècnica de València. Escuela Técnica Superior de Ingeniería del Diseño - Escola Tècnica Superior d'Enginyeria del Disseny es_ES
dc.description.bibliographicCitation Albaladejo-Belmonte, M.; Prats-Boluda, G.; Ye Lin, Y.; Garfield, RE.; Garcia-Casado, J. (2022). Uterine slow wave: directionality and changes with imminent delivery. Physiological Measurement. 43(8):1-11. https://doi.org/10.1088/1361-6579/ac84c0 es_ES
dc.description.accrualMethod S es_ES
dc.relation.publisherversion https://doi.org/10.1088/1361-6579/ac84c0 es_ES
dc.description.upvformatpinicio 1 es_ES
dc.description.upvformatpfin 11 es_ES
dc.type.version info:eu-repo/semantics/publishedVersion es_ES
dc.description.volume 43 es_ES
dc.description.issue 8 es_ES
dc.identifier.pmid 35896091 es_ES
dc.relation.pasarela S\471194 es_ES
dc.contributor.funder GENERALITAT VALENCIANA es_ES
dc.contributor.funder AGENCIA ESTATAL DE INVESTIGACION es_ES
dc.contributor.funder European Regional Development Fund es_ES
dc.subject.ods 03.- Garantizar una vida saludable y promover el bienestar para todos y todas en todas las edades es_ES


Este ítem aparece en la(s) siguiente(s) colección(ones)

Mostrar el registro sencillo del ítem