- -

Behaviour of retrofited precast UHPC and Ni-Ti SMA column-to-foundation connection with CFRP wrapping layers

RiuNet: Repositorio Institucional de la Universidad Politécnica de Valencia

Compartir/Enviar a

Citas

Estadísticas

  • Estadisticas de Uso

Behaviour of retrofited precast UHPC and Ni-Ti SMA column-to-foundation connection with CFRP wrapping layers

Mostrar el registro sencillo del ítem

Ficheros en el ítem

dc.contributor.author Pereiro-Barceló, Javier es_ES
dc.contributor.author Bonet Senach, José Luís es_ES
dc.contributor.author Rueda-García, Lisbel es_ES
dc.contributor.author Ciurana-Tatay, Álvaro es_ES
dc.date.accessioned 2023-02-13T19:00:33Z
dc.date.available 2023-02-13T19:00:33Z
dc.date.issued 2022-03-14 es_ES
dc.identifier.issn 0950-0618 es_ES
dc.identifier.uri http://hdl.handle.net/10251/191800
dc.description.abstract [EN] Four precast column-to-foundation connection specimens, previously tested under lateral reversed cyclic loading and constant axial load (first-stage tests), were repaired with Carbon Fibre Reinforced Polymer (CFRP) layers in the areas where plastic hinges had formed and were retested under the same loads (second-stage tests). The columns were originally manufactured with ultrahigh-performance concrete (UHPC) with high stee-fibre content (volumetric steel/fibre ratio 1.9%). The steel bars in the connection were replaced with superelastic Ni-Ti SMA bars that crossed the column/foundation interface. Two types of connection between the precast column and the foundation were analysed: protruding bars and smooth pocket bars (SP). The specimens were subjected to the same constant level of relative axial load in both the first and second-stage tests. The objective was to determine whether the initial performance of precast UHPC and SMA reinforced column-to-foundation connections against lateral cyclic loads can be restored after a seismic event by means of simple and economic retrofitting. The effectiveness of the number of strengthening CFRP layers was also studied (two or three CFRP wrapping layers) for each column-to-foundation connection type. The main results for PB and SP connection specimens with respect to the original specimens were respectively: an average strength capacity loss of 8% and 19%, displacement ductility increase of 8% and 42%, dissipated energy 48% and 53% higher and initial stiffness 9.5% and 21% lower. No significant differences were observed in the repairs done with two or three CFRP wrapping layers. es_ES
dc.description.sponsorship This paper forms part of a line of research carried out at the University Institute of Concrete Science and Technology (ICITECH) of the Universitat Politecnica de Valencia. The authors wish to thank the Spanish Ministry of Science and Innovation for the support provided through Projects BIA2012-32645 and RTI2018-099091-B-C21-AR, and Grant BES-2016-078010 from the European Union for the financial support with FEDER funds, and the Spanish Ministry of Education, Culture and Sport for Grant FPU12/01451. es_ES
dc.language Inglés es_ES
dc.publisher Elsevier es_ES
dc.relation.ispartof Construction and Building Materials es_ES
dc.rights Reconocimiento - No comercial - Sin obra derivada (by-nc-nd) es_ES
dc.subject UHPC es_ES
dc.subject Ni-Ti es_ES
dc.subject SMA es_ES
dc.subject CFRP es_ES
dc.subject Self-centring es_ES
dc.subject Retrofitting es_ES
dc.subject Cyclic load es_ES
dc.subject Ductility es_ES
dc.subject Residual drift ratio es_ES
dc.subject.classification INGENIERIA DE LA CONSTRUCCION es_ES
dc.title Behaviour of retrofited precast UHPC and Ni-Ti SMA column-to-foundation connection with CFRP wrapping layers es_ES
dc.type Artículo es_ES
dc.identifier.doi 10.1016/j.conbuildmat.2022.126536 es_ES
dc.relation.projectID info:eu-repo/grantAgreement/AEI/Plan Estatal de Investigación Científica y Técnica y de Innovación 2017-2020/RTI2018-099091-B-C21/ES/MEJORA DE LA SOSTENIBILIDAD, SEGURIDAD Y RESILIENCIA DE LA CONEXION ENTRE VIGAS SEGMENTADAS PREFABRICADAS DE HORMIGON MEDIANTE EL USO DE NUEVOS MATERIALES/ es_ES
dc.relation.projectID info:eu-repo/grantAgreement/MINECO//BIA2012-32645//Estrategias de mejora de la ductilidad frente a acciones sísmicas de uniones de elementos prefabricados mediante el empleo de nuevos materiales/ es_ES
dc.relation.projectID info:eu-repo/grantAgreement/MECD//AP2012-1451/ES/AP2012-1451/ es_ES
dc.relation.projectID info:eu-repo/grantAgreement/AEI//BES-2016-078010//AYUDAS PARA CONTRATOS PREDOCTORALES PARA LA FORMACION DE DOCTORES-RUEDA GARCIA/ es_ES
dc.rights.accessRights Abierto es_ES
dc.contributor.affiliation Universitat Politècnica de València. Escuela Técnica Superior de Ingenieros de Caminos, Canales y Puertos - Escola Tècnica Superior d'Enginyers de Camins, Canals i Ports es_ES
dc.description.bibliographicCitation Pereiro-Barceló, J.; Bonet Senach, JL.; Rueda-García, L.; Ciurana-Tatay, Á. (2022). Behaviour of retrofited precast UHPC and Ni-Ti SMA column-to-foundation connection with CFRP wrapping layers. Construction and Building Materials. 323:1-17. https://doi.org/10.1016/j.conbuildmat.2022.126536 es_ES
dc.description.accrualMethod S es_ES
dc.relation.publisherversion https://doi.org/10.1016/j.conbuildmat.2022.126536 es_ES
dc.description.upvformatpinicio 1 es_ES
dc.description.upvformatpfin 17 es_ES
dc.type.version info:eu-repo/semantics/publishedVersion es_ES
dc.description.volume 323 es_ES
dc.relation.pasarela S\454133 es_ES
dc.contributor.funder MINISTERIO DE EDUCACION es_ES
dc.contributor.funder AGENCIA ESTATAL DE INVESTIGACION es_ES
dc.contributor.funder MINISTERIO DE ECONOMIA Y EMPRESA es_ES
dc.contributor.funder European Regional Development Fund es_ES


Este ítem aparece en la(s) siguiente(s) colección(ones)

Mostrar el registro sencillo del ítem