Mostrar el registro sencillo del ítem
dc.contributor.author | Pereiro-Barceló, Javier | es_ES |
dc.contributor.author | Bonet Senach, José Luís | es_ES |
dc.contributor.author | Rueda-García, Lisbel | es_ES |
dc.contributor.author | Ciurana-Tatay, Álvaro | es_ES |
dc.date.accessioned | 2023-02-13T19:00:33Z | |
dc.date.available | 2023-02-13T19:00:33Z | |
dc.date.issued | 2022-03-14 | es_ES |
dc.identifier.issn | 0950-0618 | es_ES |
dc.identifier.uri | http://hdl.handle.net/10251/191800 | |
dc.description.abstract | [EN] Four precast column-to-foundation connection specimens, previously tested under lateral reversed cyclic loading and constant axial load (first-stage tests), were repaired with Carbon Fibre Reinforced Polymer (CFRP) layers in the areas where plastic hinges had formed and were retested under the same loads (second-stage tests). The columns were originally manufactured with ultrahigh-performance concrete (UHPC) with high stee-fibre content (volumetric steel/fibre ratio 1.9%). The steel bars in the connection were replaced with superelastic Ni-Ti SMA bars that crossed the column/foundation interface. Two types of connection between the precast column and the foundation were analysed: protruding bars and smooth pocket bars (SP). The specimens were subjected to the same constant level of relative axial load in both the first and second-stage tests. The objective was to determine whether the initial performance of precast UHPC and SMA reinforced column-to-foundation connections against lateral cyclic loads can be restored after a seismic event by means of simple and economic retrofitting. The effectiveness of the number of strengthening CFRP layers was also studied (two or three CFRP wrapping layers) for each column-to-foundation connection type. The main results for PB and SP connection specimens with respect to the original specimens were respectively: an average strength capacity loss of 8% and 19%, displacement ductility increase of 8% and 42%, dissipated energy 48% and 53% higher and initial stiffness 9.5% and 21% lower. No significant differences were observed in the repairs done with two or three CFRP wrapping layers. | es_ES |
dc.description.sponsorship | This paper forms part of a line of research carried out at the University Institute of Concrete Science and Technology (ICITECH) of the Universitat Politecnica de Valencia. The authors wish to thank the Spanish Ministry of Science and Innovation for the support provided through Projects BIA2012-32645 and RTI2018-099091-B-C21-AR, and Grant BES-2016-078010 from the European Union for the financial support with FEDER funds, and the Spanish Ministry of Education, Culture and Sport for Grant FPU12/01451. | es_ES |
dc.language | Inglés | es_ES |
dc.publisher | Elsevier | es_ES |
dc.relation.ispartof | Construction and Building Materials | es_ES |
dc.rights | Reconocimiento - No comercial - Sin obra derivada (by-nc-nd) | es_ES |
dc.subject | UHPC | es_ES |
dc.subject | Ni-Ti | es_ES |
dc.subject | SMA | es_ES |
dc.subject | CFRP | es_ES |
dc.subject | Self-centring | es_ES |
dc.subject | Retrofitting | es_ES |
dc.subject | Cyclic load | es_ES |
dc.subject | Ductility | es_ES |
dc.subject | Residual drift ratio | es_ES |
dc.subject.classification | INGENIERIA DE LA CONSTRUCCION | es_ES |
dc.title | Behaviour of retrofited precast UHPC and Ni-Ti SMA column-to-foundation connection with CFRP wrapping layers | es_ES |
dc.type | Artículo | es_ES |
dc.identifier.doi | 10.1016/j.conbuildmat.2022.126536 | es_ES |
dc.relation.projectID | info:eu-repo/grantAgreement/AEI/Plan Estatal de Investigación Científica y Técnica y de Innovación 2017-2020/RTI2018-099091-B-C21/ES/MEJORA DE LA SOSTENIBILIDAD, SEGURIDAD Y RESILIENCIA DE LA CONEXION ENTRE VIGAS SEGMENTADAS PREFABRICADAS DE HORMIGON MEDIANTE EL USO DE NUEVOS MATERIALES/ | es_ES |
dc.relation.projectID | info:eu-repo/grantAgreement/MINECO//BIA2012-32645//Estrategias de mejora de la ductilidad frente a acciones sísmicas de uniones de elementos prefabricados mediante el empleo de nuevos materiales/ | es_ES |
dc.relation.projectID | info:eu-repo/grantAgreement/MECD//AP2012-1451/ES/AP2012-1451/ | es_ES |
dc.relation.projectID | info:eu-repo/grantAgreement/AEI//BES-2016-078010//AYUDAS PARA CONTRATOS PREDOCTORALES PARA LA FORMACION DE DOCTORES-RUEDA GARCIA/ | es_ES |
dc.rights.accessRights | Abierto | es_ES |
dc.contributor.affiliation | Universitat Politècnica de València. Escuela Técnica Superior de Ingenieros de Caminos, Canales y Puertos - Escola Tècnica Superior d'Enginyers de Camins, Canals i Ports | es_ES |
dc.description.bibliographicCitation | Pereiro-Barceló, J.; Bonet Senach, JL.; Rueda-García, L.; Ciurana-Tatay, Á. (2022). Behaviour of retrofited precast UHPC and Ni-Ti SMA column-to-foundation connection with CFRP wrapping layers. Construction and Building Materials. 323:1-17. https://doi.org/10.1016/j.conbuildmat.2022.126536 | es_ES |
dc.description.accrualMethod | S | es_ES |
dc.relation.publisherversion | https://doi.org/10.1016/j.conbuildmat.2022.126536 | es_ES |
dc.description.upvformatpinicio | 1 | es_ES |
dc.description.upvformatpfin | 17 | es_ES |
dc.type.version | info:eu-repo/semantics/publishedVersion | es_ES |
dc.description.volume | 323 | es_ES |
dc.relation.pasarela | S\454133 | es_ES |
dc.contributor.funder | MINISTERIO DE EDUCACION | es_ES |
dc.contributor.funder | AGENCIA ESTATAL DE INVESTIGACION | es_ES |
dc.contributor.funder | MINISTERIO DE ECONOMIA Y EMPRESA | es_ES |
dc.contributor.funder | European Regional Development Fund | es_ES |