- -

Assessment of common information in surface electromyography recordings with adhesive electrodes and an intravaginal probe

RiuNet: Repositorio Institucional de la Universidad Politécnica de Valencia

Compartir/Enviar a

Citas

Estadísticas

  • Estadisticas de Uso

Assessment of common information in surface electromyography recordings with adhesive electrodes and an intravaginal probe

Mostrar el registro sencillo del ítem

Ficheros en el ítem

dc.contributor.author Mira-Tomás, J. M. es_ES
dc.contributor.author Albaladejo-Belmonte, Mónica es_ES
dc.contributor.author Guijarro Estelles, Enrique es_ES
dc.contributor.author Villa-Muñoz, P. es_ES
dc.contributor.author Nohales-Alfonso, F. J. es_ES
dc.contributor.author Alberola-Rubio, J. es_ES
dc.contributor.author Garcia-Casado, Javier es_ES
dc.date.accessioned 2023-03-06T10:36:49Z
dc.date.available 2023-03-06T10:36:49Z
dc.date.issued 2022-11-25 es_ES
dc.identifier.isbn 978-84-09-45972-8 es_ES
dc.identifier.uri http://hdl.handle.net/10251/192328
dc.description.abstract [EN] Dysfunctions in pelvic floor muscles (PFM) are a highly prevalent group of pathologies which critically alter daily life activities. Surface electromyography (sEMG) of PFM has emerged as a potential evaluative tool but recordings are affected by interferences of nearby muscle groups. The aim of this study is to assess the association between internal and external sEMG signals in order to better identify the different PFM sources. Four monopolar and two bipolar signals were recorded from the perineum (external recordings), and two monopolar signals with an intravaginal probe in 32 women with vulvodynia.. Cross correlation (CC) and normalized mutual information (NMI) were computed between signal pairs to assess their common information. External monopolar electrodes showed high CC (82 %) and NMI (19 %) among them, probably due to common mode interferences and volume conduction. External monopolar signals on posterior PFM have relevant common information with probe signals of the same side (CC: 55 %, NMI:6.5 %), suggesting that deep PFM activity could be monitored without using intravaginal probes, which are painful for some patients. Little common information was found between intravaginal probe and external bipolar signals, suggesting that deep and surface activity can be assessed separately with these recordings set-ups. These findings can be relevant for the recording and interpretation of sEMG signals when assesing PFM electrophysilogical condition in the clinical management of PFM disorders es_ES
dc.description.sponsorship This study was funded by Generalitat Valenciana in Programa para la promoción de I+D+i ACIF/2021/012, AICO/2021/126; and by private contracts from Merz Pharmaceuticals GmbH S.L. es_ES
dc.language Inglés es_ES
dc.publisher Universidad de Valladolid es_ES
dc.relation.ispartof Libro de Actas CASEIB 2022 es_ES
dc.rights Reconocimiento - No comercial - Compartir igual (by-nc-sa) es_ES
dc.subject Pelvic floor muscles es_ES
dc.subject Surface electromyography es_ES
dc.subject Common information es_ES
dc.subject.classification TECNOLOGIA ELECTRONICA es_ES
dc.title Assessment of common information in surface electromyography recordings with adhesive electrodes and an intravaginal probe es_ES
dc.type Comunicación en congreso es_ES
dc.type Capítulo de libro es_ES
dc.relation.projectID info:eu-repo/grantAgreement///AICO%2F2021%2F126//Desarrollo de herramientas de uso clínico basadas en electromiografía de superficie para el diagnóstico de la vulvodinia y seguimiento de su tratamiento con toxina botulínica/ es_ES
dc.relation.projectID info:eu-repo/grantAgreement/GVA//ACIF%2F2021%2F012//Programa para la promoción de I+D+i/ es_ES
dc.rights.accessRights Abierto es_ES
dc.contributor.affiliation Universitat Politècnica de València. Escuela Técnica Superior de Ingenieros Industriales - Escola Tècnica Superior d'Enginyers Industrials es_ES
dc.description.bibliographicCitation Mira-Tomás, JM.; Albaladejo-Belmonte, M.; Guijarro Estelles, E.; Villa-Muñoz, P.; Nohales-Alfonso, FJ.; Alberola-Rubio, J.; Garcia-Casado, J. (2022). Assessment of common information in surface electromyography recordings with adhesive electrodes and an intravaginal probe. Universidad de Valladolid. 398-401. http://hdl.handle.net/10251/192328 es_ES
dc.description.accrualMethod S es_ES
dc.relation.conferencename XL Congreso Anual de la Sociedad Española de Ingeniería Biomédica (CASEIB 2022) es_ES
dc.relation.conferencedate Noviembre 23-25,2022 es_ES
dc.relation.conferenceplace Valladolid, España es_ES
dc.relation.publisherversion https://caseib.es/2022/ es_ES
dc.description.upvformatpinicio 398 es_ES
dc.description.upvformatpfin 401 es_ES
dc.type.version info:eu-repo/semantics/publishedVersion es_ES
dc.relation.pasarela S\481059 es_ES
dc.contributor.funder Generalitat Valenciana es_ES


Este ítem aparece en la(s) siguiente(s) colección(ones)

Mostrar el registro sencillo del ítem