- -

Statistical Methods for Quality Equivalence of Topical Products. 0.5 mg/g Betamethasone Ointment as a Case-Study

RiuNet: Repositorio Institucional de la Universidad Politécnica de Valencia

Compartir/Enviar a

Citas

Estadísticas

  • Estadisticas de Uso

Statistical Methods for Quality Equivalence of Topical Products. 0.5 mg/g Betamethasone Ointment as a Case-Study

Mostrar el registro sencillo del ítem

Ficheros en el ítem

dc.contributor.author Ocaña, Jordi es_ES
dc.contributor.author Monleón-Getino, Toni es_ES
dc.contributor.author Merino, Virginia es_ES
dc.contributor.author Peris, Daniel es_ES
dc.contributor.author Soler, Lluís es_ES
dc.date.accessioned 2023-04-26T18:01:18Z
dc.date.available 2023-04-26T18:01:18Z
dc.date.issued 2020-04 es_ES
dc.identifier.uri http://hdl.handle.net/10251/192981
dc.description.abstract [EN] This study examines the statistical implications, and their possible implementation, of the "Draft guideline on quality and equivalence of topical products" issued by the European Medicines Agency in 2018, with particular focus on the section devoted to quality equivalence of physical properties. A new confidence interval to conduct the quality equivalence test and a way to cope with the multiplicity of quality parameters are presented and discussed. As an example, the results and the statistical analysis of a study on betamethasone 0.5 mg/g ointment are presented. It is suggested that the equivalence limits proposed in the draft guideline are overly strict: It is as difficult to declare quality equivalence between two packaging formats of the same reference product as to declare quality equivalence between the reference and the test product. es_ES
dc.language Inglés es_ES
dc.publisher MDPI AG es_ES
dc.relation.ispartof Pharmaceutics es_ES
dc.rights Reconocimiento (by) es_ES
dc.subject Fieller's confidence interval es_ES
dc.subject Equivalence test es_ES
dc.subject Batch effect es_ES
dc.subject Multiple quality variables es_ES
dc.subject Principal component analysis es_ES
dc.title Statistical Methods for Quality Equivalence of Topical Products. 0.5 mg/g Betamethasone Ointment as a Case-Study es_ES
dc.type Artículo es_ES
dc.identifier.doi 10.3390/pharmaceutics12040318 es_ES
dc.rights.accessRights Abierto es_ES
dc.description.bibliographicCitation Ocaña, J.; Monleón-Getino, T.; Merino, V.; Peris, D.; Soler, L. (2020). Statistical Methods for Quality Equivalence of Topical Products. 0.5 mg/g Betamethasone Ointment as a Case-Study. Pharmaceutics. 12(4):1-16. https://doi.org/10.3390/pharmaceutics12040318 es_ES
dc.description.accrualMethod S es_ES
dc.relation.publisherversion https://doi.org/10.3390/pharmaceutics12040318 es_ES
dc.description.upvformatpinicio 1 es_ES
dc.description.upvformatpfin 16 es_ES
dc.type.version info:eu-repo/semantics/publishedVersion es_ES
dc.description.volume 12 es_ES
dc.description.issue 4 es_ES
dc.identifier.eissn 1999-4923 es_ES
dc.identifier.pmid 32252358 es_ES
dc.identifier.pmcid PMC7238222 es_ES
dc.relation.pasarela S\436608 es_ES


Este ítem aparece en la(s) siguiente(s) colección(ones)

Mostrar el registro sencillo del ítem