Comprehensive Analysis of Principal Slot Harmonics as Reliable Indicators for Early Detection of Inter-Turn Faults in Induction Motors of Deep-Well Submersible Pumps

RiuNet: Repositorio Institucional de la Universidad Politécnica de Valencia

Compartir/Enviar a

Citas

Estadísticas

  • Estadisticas de Uso

Comprehensive Analysis of Principal Slot Harmonics as Reliable Indicators for Early Detection of Inter-Turn Faults in Induction Motors of Deep-Well Submersible Pumps

Mostrar el registro sencillo del ítem

Ficheros en el ítem

dc.contributor.author Bonet-Jara, Jorge es_ES
dc.contributor.author Pons Llinares, Joan es_ES
dc.contributor.author Gyftakis, Konstantinos N. es_ES
dc.date.accessioned 2023-07-04T18:01:31Z
dc.date.available 2023-07-04T18:01:31Z
dc.date.issued 2023-11 es_ES
dc.identifier.issn 0278-0046 es_ES
dc.identifier.uri http://hdl.handle.net/10251/194671
dc.description 2023 IEEE. Personal use of this material is permitted. Permissíon from IEEE must be obtained for all other uses, in any current or future media, including reprinting/republishing this material for advertisíng or promotional purposes, creating new collective works, for resale or redistribution to servers or lists, or reuse of any copyrighted component of this work in other works. es_ES
dc.description.abstract [EN] Early detection of interturn faults is one of the most important issues in electrical machines, as the fault severity evolves very fast to a catastrophic failure due to the high thermal stress. However, as this article shows, in submersible induction motors for deep-well pumps, it evolves slower. These motors are highly water-cooled, which significantly reduces the thermal stress caused by the fault, increasing the possibility of early detection. Among fault detection methods, only those based on line current/voltage measurements can be used, as motors are at great depths. This article investigates the principal slot harmonics as reliable indicators for early detection of interturn faults in this application. To this end, a comprehensive analysis is conducted using finite-element analysis where the behavior of these harmonics is studied under different fault severities, both alone and coexisting with other asymmetries, such as unbalanced voltages, eccentricity, or rotor faults. The findings are used to develop a reliable diagnostic scheme based on the monitoring of the most fault-sensitive harmonics along with the voltage and current unbalance indexes. Finally, the scheme is applied, for the first time, in the context of continuous monitoring of a 230-HP induction motor showing its efficacy. es_ES
dc.description.sponsorship This work was supported in part by the Universitat Politecnica de Valencia and in part by the Spanish Ministry of Science, Innovation and Universities under Grant FPU19/02698. es_ES
dc.language Inglés es_ES
dc.publisher Institute of Electrical and Electronics Engineers es_ES
dc.relation.ispartof IEEE Transactions on Industrial Electronics es_ES
dc.rights Reserva de todos los derechos es_ES
dc.subject Condition monitoring es_ES
dc.subject Fault diagnosis es_ES
dc.subject Finite-element analysis (FEA) es_ES
dc.subject Induction motors es_ES
dc.subject Interturn faults es_ES
dc.subject Motor current signature analysis (MCSA) es_ES
dc.subject Pumps es_ES
dc.subject.classification INGENIERIA ELECTRICA es_ES
dc.title Comprehensive Analysis of Principal Slot Harmonics as Reliable Indicators for Early Detection of Inter-Turn Faults in Induction Motors of Deep-Well Submersible Pumps es_ES
dc.type Artículo es_ES
dc.identifier.doi 10.1109/TIE.2022.3231333 es_ES
dc.relation.projectID info:eu-repo/grantAgreement/ //FPU19%2F02698//AYUDA PREDOCTORAL FPU-BONET JARA. PROYECTO: ALGORITMO DE ESTIMACIÓN AUTOMÁTICA DE LA VELOCIDAD PARA EL DIAGNÓSTICO Y DETERMINACIÓN DE LA EFICIENCIA DE MOTORES DE INDUCCIÓN./ es_ES
dc.relation.projectID info:eu-repo/grantAgreement/AGENCIA ESTATAL DE INVESTIGACION//RTC-2017-5902-7-AR//ANÁLISIS DE LA CORRELACIÓN DE INDICADORES ELÉCTRICOS CON EL ESTADO DEL COJINETE DE EMPUJE EN BOMBAS COMPLETAMENTE SUMERGIDAS PARA EL DESARROLLO DE UN SISTEMA DE MONITORIZACIÓN AUTOMÁTICA/ es_ES
dc.rights.accessRights Abierto es_ES
dc.contributor.affiliation Universitat Politècnica de València. Departamento de Ingeniería Eléctrica - Departament d'Enginyeria Elèctrica es_ES
dc.contributor.affiliation Universitat Politècnica de València. Escuela Técnica Superior de Ingeniería del Diseño - Escola Tècnica Superior d'Enginyeria del Disseny es_ES
dc.description.bibliographicCitation Bonet-Jara, J.; Pons Llinares, J.; Gyftakis, KN. (2023). Comprehensive Analysis of Principal Slot Harmonics as Reliable Indicators for Early Detection of Inter-Turn Faults in Induction Motors of Deep-Well Submersible Pumps. IEEE Transactions on Industrial Electronics. 70(11):11692-11702. https://doi.org/10.1109/TIE.2022.3231333 es_ES
dc.description.accrualMethod S es_ES
dc.relation.publisherversion https://doi.org/10.1109/TIE.2022.3231333 es_ES
dc.description.upvformatpinicio 11692 es_ES
dc.description.upvformatpfin 11702 es_ES
dc.type.version info:eu-repo/semantics/publishedVersion es_ES
dc.description.volume 70 es_ES
dc.description.issue 11 es_ES
dc.relation.pasarela S\480148 es_ES
dc.contributor.funder AGENCIA ESTATAL DE INVESTIGACION es_ES
dc.contributor.funder MINISTERIO DE UNIVERSIDADES E INVESTIGACION es_ES


Este ítem aparece en la(s) siguiente(s) colección(ones)