Análisis del efecto de la forma geométrica y la técnica de implantación del componente glenoideo en prótesis anatómicas de hombro

RiuNet: Repositorio Institucional de la Universidad Politécnica de Valencia

Compartir/Enviar a

Citas

Estadísticas

  • Estadisticas de Uso

Análisis del efecto de la forma geométrica y la técnica de implantación del componente glenoideo en prótesis anatómicas de hombro

Mostrar el registro sencillo del ítem

Ficheros en el ítem

dc.contributor.advisor Rupérez Moreno, María José es_ES
dc.contributor.author Martín Molina, Javier es_ES
dc.date.accessioned 2023-09-21T06:55:34Z
dc.date.available 2023-09-21T06:55:34Z
dc.date.created 2023-07-14
dc.date.issued 2023-09-21 es_ES
dc.identifier.uri http://hdl.handle.net/10251/196847
dc.description.abstract [ES] El hombro es una de las articulaciones con mayor prevalencia de desórdenes musculoesqueléticos en el cuerpo humano y, en casos severos, tiende a recurrir a la artroplastia de hombro. Esto no sólo repercute seriamente en la vida de las personas que padecen las afecciones, sino que supone una importante carga para el sistema sanitario. En el actual trabajo se ha estudiado el comportamiento biomecánico de varios modelos comunes de componentes glenoideos empleados en este ámbito con el fin de analizar la seguridad de estos. Para ello se examinó a fondo el estado del arte referente a las geometrías y técnicas o trayectorias de implantación y se construyeron sobre la escápula los respectivos modelos con programas CAD. Para un mayor realismo, la geometría y propiedades de la escápula se obtuvieron a través de softwares específicos de segmentación y mapeado densitométricos. Tras el modelado, se incorporaron a un programa CAE las geometrías, las propiedades de los distintos materiales, las condiciones de contorno y las fuerzas según el ángulo de elevación del humero. Tras llevar a cabo un análisis por el método de los elementos finitos (MEF), los resultados de la simulación mostraron la distribución de tensiones y deformaciones en los distintos componentes. Los resultados obtenidos indican, en general, un uso seguro de los tres modelos de implantes y de las dos colocaciones; con preferencia por la geometría incrustada (inlay), seguida del tipo clavija (pegs) y con relativamente baja influencia de la colocación empleada. En algunos casos, el efecto de concentración de tensiones genera tensiones puntuales que podrían afectar a medio ¿ largo plazo al hueso trabecular. Sin embargo, la estabilidad del resto de estructuras, especialmente el hueso cortical, se encuentra más que garantizada. De este trabajo se puede concluir que ciertas combinaciones de geometría y trayectoria de colocación favorecen la seguridad de los componentes articulares sobre otras y, tal como se ha comprobado, los resultados respetan la jerarquía presente en la literatura científica hasta la fecha. es_ES
dc.description.abstract [EN] The shoulder is one of the joints with the highest prevalence of musculoskeletal disorders in the human body and, in severe cases, tends to resort to shoulder arthroplasty. This not only seriously impacts the lives of people with the conditions, but places a significant burden on the healthcare system. In the current work, the biomechanical behavior of several common models of glenoid components used in this field has been studied in order to analyze their safety. For this, the state of the art regarding the geometries and techniques or implantation trajectories was thoroughly examined and the respective models were built on the scapula with CAD programs. For greater realism, the geometry and properties of the scapula were obtained through specific densitometric mapping and segmentation software. After the modeling, the geometries, the properties of the different materials, the boundary conditions and the forces according to the elevation angle of the flue were incorporated into a CAE program. After carrying out an analysis by the finite element method (FEM), the simulation results showed the distribution of stresses and deformations in the different components. The results obtained indicate, in general, a safe use of the three models of implants and of the two placements; with preference for the embedded geometry (inlay), followed by the peg type (pegs) and with relatively little influence of the placement used. In some cases, the stress concentration effect generates specific stresses that could affect trabecular bone in the medium to long term. However, the stability of the rest of the structures, especially the cortical bone, is more than guaranteed. From this work it can be concluded that certain combinations of geometry and placement trajectory favor the safety of joint components over others and, as has been verified, the results respect the hierarchy present in the scientific literature to date. es_ES
dc.format.extent 68 es_ES
dc.language Español es_ES
dc.publisher Universitat Politècnica de València es_ES
dc.rights Reconocimiento - No comercial - Sin obra derivada (by-nc-nd) es_ES
dc.subject Prótesis anatómicas es_ES
dc.subject Clavijas es_ES
dc.subject Quilla es_ES
dc.subject Incrustado es_ES
dc.subject Colocación alternativa es_ES
dc.subject Colocación estándar es_ES
dc.subject Articulación glenohumeral es_ES
dc.subject CAD es_ES
dc.subject Elementos finitos es_ES
dc.subject Rango de tensión es_ES
dc.subject Factor de seguridad. es_ES
dc.subject Anatomical prostheses es_ES
dc.subject Pegs es_ES
dc.subject Keel es_ES
dc.subject Inlay es_ES
dc.subject Alternative placement es_ES
dc.subject Standard placement es_ES
dc.subject Glenohumeral joint es_ES
dc.subject Finite elements es_ES
dc.subject Stress range es_ES
dc.subject Security factor. es_ES
dc.subject.classification INGENIERIA MECANICA es_ES
dc.subject.other Grado en Ingeniería Biomédica-Grau en Enginyeria Biomèdica es_ES
dc.title Análisis del efecto de la forma geométrica y la técnica de implantación del componente glenoideo en prótesis anatómicas de hombro es_ES
dc.title.alternative Analysis of the effect of the geometric shape and the implantation technique of the glenoid component in anatomical shoulder prostheses es_ES
dc.title.alternative Anàlisi de l'efecte de la forma geomètrica i la tècnica d'implantació del component glenoide en pròtesis anatòmiques d'espatlla es_ES
dc.type Proyecto/Trabajo fin de carrera/grado es_ES
dc.rights.accessRights Abierto es_ES
dc.contributor.affiliation Universitat Politècnica de València. Departamento de Ingeniería Mecánica y de Materiales - Departament d'Enginyeria Mecànica i de Materials es_ES
dc.contributor.affiliation Universitat Politècnica de València. Escuela Técnica Superior de Ingenieros Industriales - Escola Tècnica Superior d'Enginyers Industrials es_ES
dc.description.bibliographicCitation Martín Molina, J. (2023). Análisis del efecto de la forma geométrica y la técnica de implantación del componente glenoideo en prótesis anatómicas de hombro. Universitat Politècnica de València. http://hdl.handle.net/10251/196847 es_ES
dc.description.accrualMethod TFGM es_ES
dc.relation.pasarela TFGM\157231 es_ES


Este ítem aparece en la(s) siguiente(s) colección(ones)

Mostrar el registro sencillo del ítem