Lucío, MI.; Hernández-Montoto, A.; Fernández-Sánchez, ME.; Alamri, S.; Kunze, T.; Bañuls Polo, M.; Maquieira Catala, Á. (2021). Label-free detection of C-Reactive protein using bioresponsive hydrogel-based surface relief diffraction gratings. Biosensors and Bioelectronics. 193:1-10. https://doi.org/10.1016/j.bios.2021.113561
Por favor, use este identificador para citar o enlazar este ítem: http://hdl.handle.net/10251/196854
Título:
|
Label-free detection of C-Reactive protein using bioresponsive hydrogel-based surface relief diffraction gratings
|
Autor:
|
Lucío, María Isabel
Hernández-Montoto, Andy
Fernández-Sánchez, María Estrella
Alamri, Sabri
Kunze, Tim
Bañuls Polo, María-José
Maquieira Catala, Ángel
|
Entidad UPV:
|
Universitat Politècnica de València. Instituto de Reconocimiento Molecular y Desarrollo Tecnológico - Institut de Reconeixement Molecular i Desenvolupament Tecnològic
Universitat Politècnica de València. Escuela Técnica Superior de Ingeniería Agronómica y del Medio Natural - Escola Tècnica Superior d'Enginyeria Agronòmica i del Medi Natural
Universitat Politècnica de València. Departamento de Química - Departament de Química
|
Fecha difusión:
|
|
Resumen:
|
[EN] Responsive hydrogel-based surface relief gratings have demonstrated great performances as transducers in optical sensing. However, novel and smart designs of hydrogels are needed for the appropriate detection of ...[+]
[EN] Responsive hydrogel-based surface relief gratings have demonstrated great performances as transducers in optical sensing. However, novel and smart designs of hydrogels are needed for the appropriate detection of analytes and biomolecules since the existing materials are very limited to specific molecules. In this work, a biosensing system based on surface relief gratings made of bioresponsive hydrogels has been developed. In particular, the hydrogel contains phosphocholine moieties to specifically recognize C-Reactive protein (CRP). The CRP-Sensing hydrogel capacity to selectively detect CRP was fully demonstrated. Using Direct Laser Interference Patterning, micro-gratings were created on CRP-Sensing hydrogel substrates and applied for the label-free sensing of CRP using a simple laser-based homemade optical setup. Limits of detection (LOD) and quantification (LOQ) in human serum dilutions of 1.07 and 8.92 mg L-1, respectively, were reached. These results demonstrate that the biosensing system allows the selective label-free detection of CRP within concentration ranges around those related to risks of cardiovascular diseases and sepsis. Besides, amplification strategies have been carried out improving the sensitivity, widening the linear range, and reaching better LOD and LOQ (0.30 mg L-1 and 4.36 mg L-1). Finally, all the approaches were tested for the quantification of CRP in certified human serum with recoveries of around 100%.
[-]
|
Palabras clave:
|
Biosensor
,
Diffraction
,
Label-free
,
Surface relief gratings
,
Responsive hydrogel
,
C-Reactive protein
|
Derechos de uso:
|
Reconocimiento - No comercial - Sin obra derivada (by-nc-nd)
|
Fuente:
|
Biosensors and Bioelectronics. (issn:
0956-5663
)
|
DOI:
|
10.1016/j.bios.2021.113561
|
Editorial:
|
Elsevier
|
Versión del editor:
|
https://doi.org/10.1016/j.bios.2021.113561
|
Código del Proyecto:
|
info:eu-repo/grantAgreement/AEI/Plan Estatal de Investigación Científica y Técnica y de Innovación 2017-2020/PID2019-110713RB-I00/ES/HACIA EL BIOSENSADO HOLOGRAFICO AVANZADO/
info:eu-repo/grantAgreement/GENERALITAT VALENCIANA//PROMETEO%2F2020%2F094//HOLOGRAFÍA. UNA VIA PARA AFRONTAR NUEVOS RETOS EN BIOSENSADO/
info:eu-repo/grantAgreement/MINECO//IJC 2018-035355-I/
info:eu-repo/grantAgreement/AEI//CTQ2016-75749-R//BIOSENSORES HOLOGRAFICOS. PRUEBA DE CONCEPTO Y DEMOSTRACION EN APLICACIONES CLINICAS/
info:eu-repo/grantAgreement/AEI//FJCI-2016-29593//AYUDA JUAN DE LA CIERVA FORMACION-LUCIO BENITO/
|
Agradecimientos:
|
This work was financially supported by the E.U. FEDER, the Spanish
Ministry of Economy and Competitiveness MINECO (BiHolog-CTQ2016-
75749-R and AdBiHol-PID2019-110713RB-I00) and Generalitat
Valenciana (PROMETEO/2020/094). ...[+]
This work was financially supported by the E.U. FEDER, the Spanish
Ministry of Economy and Competitiveness MINECO (BiHolog-CTQ2016-
75749-R and AdBiHol-PID2019-110713RB-I00) and Generalitat
Valenciana (PROMETEO/2020/094). M. I. Lucío acknowledges
MINECO for her Juan de la Cierva Formacion and Incorporacion grants
(FJCI-2016-29593, IJC 2018-035355-I). The authors acknowledge the
assistance and advice of the Electron Microscopy Service of the Universitat Politècnica de València.
[-]
|
Tipo:
|
Artículo
|