dc.description.abstract | [EN] Objetive: This work aimed to analyze the cut-out phenomenon, which involves oblique displacements and/or rotations of the femoral head around the cephalic component of the intramedullary nail. The analysis was carried out using finite element numerical models. This technique seeks to understand the failure of this type of fixation and establish what positioning of the system favors or prevents failure due to cut-out. Material and methods: The study was carried out on a numerical model of the proximal limb of an artificial femur and an intramedullary nail type PFNA (proximal femoral nail anti-rotation). In the numerical model, the position of the intramedullary nail was varied in the anterior/posterior and superior/inferior directions to analyze the influence of the position on the cut-out phenomenon. Stresses in critical areas and torque on the nail under normal position loading were analyzed. Results: The most critical position was the one in which the intramedullary nail is placed in the superior position, due to the high compressions that appear in the trabecular bone of the femoral head. The centered position of the nail decreased the risk of bone damage and the torque that the intramedullary nail has to support. Conclusions: This type of model allows us to simulate the influence of the nail position and obtain variables that are otherwise difficult to analyze. Although it is a simple model with static load, it confirms that a centered position of the intramedullary nail reduces the risk of cut-out. | es_ES |
dc.description.abstract | [ES] Resumen Objetivo El objetivo del trabajo fue analizar el fenómeno de cut-out, fenómeno que supone desplazamientos oblicuos y/o rotaciones de la cabeza femoral alrededor del componente cefálico del clavo intramedular. El análisis se llevó a cabo mediante modelos numéricos de elementos finitos. Con esta técnica se busca entender el fallo de este tipo de fijaciones y establecer qué posicionamiento del sistema favorece o evita el fallo por cut-out. Material y métodos El estudio se realizó sobre un modelo numérico de la extremidad proximal de un fémur artificial y un clavo intramedular tipo PFNA (femoral proximal de antirrotación). En el modelo numérico se varió la posición del clavo intramedular en dirección anterior/posterior y superior/inferior para analizar la influencia de la posición en el fenómeno de cut-out. Se analizaron las tensiones en zonas críticas y par torsor sobre el clavo bajo una carga en posición normal. Resultados La posición más crítica fue aquella en la que el clavo intramedular está colocado en la posición superior, debido a las altas compresiones que aparecen en el hueso trabecular de la cabeza femoral. La posición centrada del clavo disminuyó el riesgo de daño óseo y el par torsor que tiene que soportar el clavo intramedular. Conclusión Este tipo de modelos permite simular la influencia de la posición del clavo y obtener variables que de otra manera son difíciles de analizar. Aunque se trata de un modelo sencillo con carga estática, confirma que una posición centrada del clavo intramedular disminuye el riesgo de cut-out. | es_ES |
dc.description.sponsorship | The authors are grateful for the funding received through the 2018 Spanish Society for Bone Research and Mineral Metabolism research grant. They also appreciate the Ministry of Science and Innovation funding and the ERDF Program through the projects DPI2017-89197-C2-1-R and DPI2017-89197-C2-2-R. | es_ES |
dc.language | Español | es_ES |
dc.publisher | Instituto de Salud Carlos III/BNCS/SciELO Espana | es_ES |
dc.relation.ispartof | Revista de Osteoporosis y Metabolismo Mineral | es_ES |
dc.rights | Reconocimiento - No comercial - Compartir igual (by-nc-sa) | es_ES |
dc.subject | Femur | es_ES |
dc.subject | Hip fracture | es_ES |
dc.subject | Extracapsular fracture | es_ES |
dc.subject | Intramedullary nail | es_ES |
dc.subject | Cut-out | es_ES |
dc.subject | Finite element model | es_ES |
dc.subject | Fémur | es_ES |
dc.subject | Fractura de cadera | es_ES |
dc.subject | Fractura extracapsular | es_ES |
dc.subject | Clavo intramedular | es_ES |
dc.subject | Modelo de elementos finitos | es_ES |
dc.subject.classification | INGENIERIA MECANICA | es_ES |
dc.title | El fenómeno de cut-out en fractura intertrocantérica de fémur: análisis mediante modelo de elementos finitos | es_ES |
dc.title.alternative | The cut-out phenomenon in intertrochanteric femur fracture: analysis using a finite element model | es_ES |
dc.type | Artículo | es_ES |
dc.identifier.doi | 10.4321/S1889-836X2021000100005 | es_ES |
dc.relation.projectID | info:eu-repo/grantAgreement/AEI/Plan Estatal de Investigación Científica y Técnica y de Innovación 2013-2016/DPI2017-89197-C2-1-R/ES/TALADRADO DE COMPONENTES HIBRIDOS CFRPS%2FTI Y TOLERANCIA AL DAÑO DEBIDO A MECANIZADO DURANTE EL COMPORTAMIENTO EN SERVICIO DE UNIONES ESTRUCTURALES AERONAUTICAS/ | es_ES |
dc.relation.projectID | info:eu-repo/grantAgreement/AEI//DPI2017-89197-C2-2-R-AR//TALADRADO DE COMPONENTES HIBRIDOS CFRPS/TI Y TOLERANCIA AL DAÑO DEBIDO A MECANIZADO DURANTE EL COMPORTAMIENTO EN SERVICIO DE UNIONES ESTRUCTURALES AERONAUTICAS/ | es_ES |
dc.rights.accessRights | Abierto | es_ES |
dc.contributor.affiliation | Universitat Politècnica de València. Escuela Técnica Superior de Ingeniería del Diseño - Escola Tècnica Superior d'Enginyeria del Disseny | es_ES |
dc.description.bibliographicCitation | Arias-Blanco, A.; Marco, M.; Giner Maravilla, E.; Miguélez, M.; Caeiro-Rey, J.; Larraínzar-Garijo, R. (2021). El fenómeno de cut-out en fractura intertrocantérica de fémur: análisis mediante modelo de elementos finitos. Revista de Osteoporosis y Metabolismo Mineral. 13(1):21-31. https://doi.org/10.4321/S1889-836X2021000100005 | es_ES |
dc.description.accrualMethod | S | es_ES |
dc.relation.publisherversion | https://doi.org/10.4321/S1889-836X2021000100005 | es_ES |
dc.description.upvformatpinicio | 21 | es_ES |
dc.description.upvformatpfin | 31 | es_ES |
dc.type.version | info:eu-repo/semantics/publishedVersion | es_ES |
dc.description.volume | 13 | es_ES |
dc.description.issue | 1 | es_ES |
dc.relation.pasarela | S\464304 | es_ES |
dc.contributor.funder | AGENCIA ESTATAL DE INVESTIGACION | es_ES |
dc.contributor.funder | Agencia Estatal de Investigación | es_ES |
dc.contributor.funder | European Regional Development Fund | es_ES |
dc.contributor.funder | Fundación Española de Investigación Ósea y del Metabolismo Mineral | es_ES |