- -

Evaluation of the Damper Condition in Synchronous Motors through the Analysis of the Transient Stray Fluxes and Currents considering the Effect of the Remanent Magnetism

RiuNet: Repositorio Institucional de la Universidad Politécnica de Valencia

Compartir/Enviar a

Citas

Estadísticas

  • Estadisticas de Uso

Evaluation of the Damper Condition in Synchronous Motors through the Analysis of the Transient Stray Fluxes and Currents considering the Effect of the Remanent Magnetism

Mostrar el registro sencillo del ítem

Ficheros en el ítem

dc.contributor.author Castro-Coronado, Habib es_ES
dc.contributor.author Antonino-Daviu, Jose A. es_ES
dc.contributor.author Quijano-Lopez, Alfredo es_ES
dc.contributor.author Llovera Segovia, Pedro es_ES
dc.contributor.author Fuster Roig, Vicente Luis es_ES
dc.contributor.author Serrano Iribarnegaray, Luís es_ES
dc.contributor.author Dunai, Larisa es_ES
dc.date.accessioned 2023-09-28T18:01:56Z
dc.date.available 2023-09-28T18:01:56Z
dc.date.issued 2021-09 es_ES
dc.identifier.issn 0093-9994 es_ES
dc.identifier.uri http://hdl.handle.net/10251/197317
dc.description (c) 2021 IEEE. Personal use of this material is permitted. Permission from IEEE must be obtained for all other uses, in any current or future media, including reprinting/republishing this material for advertising or promotional purposes, creating new collective works, for resale or redistribution to servers or lists, or reuse of any copyrighted component of this work in other works. es_ES
dc.description.abstract [EN] This paper proposes the qualitative and quantitative analysis of stray-flux and current data under starting to detect damper faults in cylindrical rotor synchronous machines. These machines are typically employed in high power applications and their possible outages may imply huge costs for the industries or plants where they operate. The damper cage is a critical part of these machines and a potential source of catastrophic failures. However, few research works have provided feasible alternatives to monitor the condition of such element. This work analyses the viability of analyzing the electromotive force signals induced by the stray-flux in external coil sensors as well as current signals under starting to diagnose damper faults. The results obtained with laboratory machines with different levels of damper damage show that the analyses of those signals can provide very useful information for determining how the damper degrades over time. Moreover, the paper studies the effect of the remanent magnetism over the viability of the approaches and provides solutions to overcome this problem. The conclusions are valuable for field engineers since, nowadays, there are few available solutions that allow monitoring the condition of such element without motor disassembly. es_ES
dc.description.sponsorship This work was supported in part by the Spanish "Ministerio de Ciencia Innovacion y Universidades" and in part by the FEDER program in the framework of the "Proyectos de I+D de Generacion de Conocimiento del Programa Estatal de Generacion de Conocimiento y Fortalecimiento Cientifico y Tecnologico del Sistema de I+D+i, Subprograma Estatal de Generacion de Conocimiento" (ref: PGC2018-095747-B-I00). es_ES
dc.language Inglés es_ES
dc.publisher Institute of Electrical and Electronics Engineers es_ES
dc.relation.ispartof IEEE Transactions on Industry Applications es_ES
dc.rights Reserva de todos los derechos es_ES
dc.subject Damper cage es_ES
dc.subject Fault diagnosis es_ES
dc.subject Maintenance es_ES
dc.subject Reliability es_ES
dc.subject Rotor es_ES
dc.subject Stray-flux es_ES
dc.subject Synchronous machines es_ES
dc.subject Transient analysis es_ES
dc.subject.classification INGENIERIA ELECTRICA es_ES
dc.subject.classification EXPRESION GRAFICA EN LA INGENIERIA es_ES
dc.title Evaluation of the Damper Condition in Synchronous Motors through the Analysis of the Transient Stray Fluxes and Currents considering the Effect of the Remanent Magnetism es_ES
dc.type Artículo es_ES
dc.identifier.doi 10.1109/TIA.2021.3089457 es_ES
dc.relation.projectID info:eu-repo/grantAgreement/AEI/Plan Estatal de Investigación Científica y Técnica y de Innovación 2017-2020/PGC2018-095747-B-I00/ES/TECNOLOGIAS AVANZADAS BASADAS EN EL ANALISIS DEL FLUJO DE DISPERSION EN REGIMEN TRANSITORIO PARA EL DIAGNOSTICO PRECOZ DE ANOMALIAS ELECTROMECANICAS EN MOTORES ELECTRICOS/ es_ES
dc.rights.accessRights Abierto es_ES
dc.contributor.affiliation Universitat Politècnica de València. Escuela Técnica Superior de Ingenieros Industriales - Escola Tècnica Superior d'Enginyers Industrials es_ES
dc.contributor.affiliation Universitat Politècnica de València. Escuela Técnica Superior de Ingenieros de Caminos, Canales y Puertos - Escola Tècnica Superior d'Enginyers de Camins, Canals i Ports es_ES
dc.description.bibliographicCitation Castro-Coronado, H.; Antonino-Daviu, JA.; Quijano-Lopez, A.; Llovera Segovia, P.; Fuster Roig, VL.; Serrano Iribarnegaray, L.; Dunai, L. (2021). Evaluation of the Damper Condition in Synchronous Motors through the Analysis of the Transient Stray Fluxes and Currents considering the Effect of the Remanent Magnetism. IEEE Transactions on Industry Applications. 57(5):4665-4674. https://doi.org/10.1109/TIA.2021.3089457 es_ES
dc.description.accrualMethod S es_ES
dc.relation.publisherversion https://doi.org/10.1109/TIA.2021.3089457 es_ES
dc.description.upvformatpinicio 4665 es_ES
dc.description.upvformatpfin 4674 es_ES
dc.type.version info:eu-repo/semantics/publishedVersion es_ES
dc.description.volume 57 es_ES
dc.description.issue 5 es_ES
dc.relation.pasarela S\438956 es_ES
dc.contributor.funder AGENCIA ESTATAL DE INVESTIGACION es_ES
dc.contributor.funder European Regional Development Fund es_ES


Este ítem aparece en la(s) siguiente(s) colección(ones)

Mostrar el registro sencillo del ítem