Detection of Broken Rotor Bars in Nonlinear Startups of Inverter-Fed Induction Motors

RiuNet: Repositorio Institucional de la Universidad Politécnica de Valencia

Compartir/Enviar a

Citas

Estadísticas

  • Estadisticas de Uso

Detection of Broken Rotor Bars in Nonlinear Startups of Inverter-Fed Induction Motors

Mostrar el registro sencillo del ítem

Ficheros en el ítem

dc.contributor.author Fernández-Cavero, Vanessa es_ES
dc.contributor.author Pons Llinares, Joan es_ES
dc.contributor.author Duque-Perez, Oscar es_ES
dc.contributor.author Morinigo-Sotelo, Daniel es_ES
dc.date.accessioned 2023-10-11T18:01:59Z
dc.date.available 2023-10-11T18:01:59Z
dc.date.issued 2021-06 es_ES
dc.identifier.issn 0093-9994 es_ES
dc.identifier.uri http://hdl.handle.net/10251/198019
dc.description.abstract [EN] Fault detection in induction motors powered by inverters operating in nonstationary regimes remains a challenge. The trajectory in the time-frequency plane of harmonics related to broken rotor bar develops very in proximity to the path described by the fundamental component. In addition, their energy is much lower than the amplitude of the first harmonic. These two characteristics make it challenging to observe them. The Dragon Transform (DT), here presented, is developed to overcome the described problem. In this article, the DT is assessed with nonlinear inverter-fed startups, where its high time and frequency resolutions facilitate the monitoring of fault harmonics even with highly adjacent trajectories to the first harmonic path. es_ES
dc.language Inglés es_ES
dc.publisher Institute of Electrical and Electronics Engineers es_ES
dc.relation.ispartof IEEE Transactions on Industry Applications es_ES
dc.rights Reserva de todos los derechos es_ES
dc.subject Fault detection es_ES
dc.subject Induction motors (IM) es_ES
dc.subject Inverters es_ES
dc.subject Rotors es_ES
dc.subject Time-frequency domain analysis es_ES
dc.subject.classification INGENIERIA ELECTRICA es_ES
dc.title Detection of Broken Rotor Bars in Nonlinear Startups of Inverter-Fed Induction Motors es_ES
dc.type Artículo es_ES
dc.identifier.doi 10.1109/TIA.2021.3066317 es_ES
dc.rights.accessRights Abierto es_ES
dc.contributor.affiliation Universitat Politècnica de València. Escuela Técnica Superior de Ingeniería del Diseño - Escola Tècnica Superior d'Enginyeria del Disseny es_ES
dc.description.bibliographicCitation Fernández-Cavero, V.; Pons Llinares, J.; Duque-Perez, O.; Morinigo-Sotelo, D. (2021). Detection of Broken Rotor Bars in Nonlinear Startups of Inverter-Fed Induction Motors. IEEE Transactions on Industry Applications. 57(3):2559-2568. https://doi.org/10.1109/TIA.2021.3066317 es_ES
dc.description.accrualMethod S es_ES
dc.relation.publisherversion https://doi.org/10.1109/TIA.2021.3066317 es_ES
dc.description.upvformatpinicio 2559 es_ES
dc.description.upvformatpfin 2568 es_ES
dc.type.version info:eu-repo/semantics/publishedVersion es_ES
dc.description.volume 57 es_ES
dc.description.issue 3 es_ES
dc.relation.pasarela S\445587 es_ES


Este ítem aparece en la(s) siguiente(s) colección(ones)