- -

Turmell-Meter: A Device for Estimating the Subtalar and Talocrural Axes of the Human Ankle Joint by Applying the Product of Exponentials Formula

RiuNet: Repositorio Institucional de la Universidad Politécnica de Valencia

Compartir/Enviar a

Citas

Estadísticas

  • Estadisticas de Uso

Turmell-Meter: A Device for Estimating the Subtalar and Talocrural Axes of the Human Ankle Joint by Applying the Product of Exponentials Formula

Mostrar el registro sencillo del ítem

Ficheros en el ítem

dc.contributor.author Agudelo-Varela, Óscar es_ES
dc.contributor.author Vargas-Riaño, Julio es_ES
dc.contributor.author Valera Fernández, Ángel es_ES
dc.date.accessioned 2023-10-24T18:01:14Z
dc.date.available 2023-10-24T18:01:14Z
dc.date.issued 2022-05 es_ES
dc.identifier.uri http://hdl.handle.net/10251/198745
dc.description.abstract [EN] The human ankle is a complex joint, most commonly represented as the talocrural and subtalar axes. It is troublesome to take in vivo measurements of the ankle joint. There are no instruments for patients lying on flat surfaces; employed in outdoor or remote sites. We have developed a "Turmell-meter" to address these issues. It started with the study of ankle anatomy and anthropometry. We also use the product of exponentials' formula to visualize the movements. We built a prototype using human proportions and statistics. For pose estimation, we used a trilateration method by applying tetrahedral geometry. We computed the axis direction by fitting circles in 3D, plotting the manifold and chart as an ankle joint model. We presented the results of simulations, a prototype comprising 45 parts, specifically designed draw-wire sensors, and electronics. Finally, we tested the device by capturing positions and fitting them into the bi-axial ankle model as a Riemannian manifold. The Turmell-meter is a hardware platform for human ankle joint axes estimation. The measurement accuracy and precision depend on the sensor quality; we address this issue by designing an electronics capture circuit, measuring the real measurement with a Vernier caliper. Then, we adjust the analog voltages and filter the 10-bit digital value. The Technology Readiness Level is 2. The proposed ankle joint model has the properties of a chart in a geometric manifold, and we provided the details. es_ES
dc.description.sponsorship This research was partially funded by Colciencias-Colfuturo PhD Scholarships Program Educational Credit Forgivable grant number 568, and by Vicerrectorado de Investigacion de la Universitat Politecnica de Valencia (PAID-11-21). es_ES
dc.language Inglés es_ES
dc.publisher MDPI AG es_ES
dc.relation.ispartof Bioengineering es_ES
dc.rights Reconocimiento (by) es_ES
dc.subject Human ankle model es_ES
dc.subject Product of exponentials formula es_ES
dc.subject Anthropometry es_ES
dc.subject Biomechanics es_ES
dc.subject Coordinate measuring machines es_ES
dc.subject Kinematics es_ES
dc.subject Pose estimation es_ES
dc.subject Position measurement es_ES
dc.subject Biomedical informatics es_ES
dc.subject.classification INGENIERIA DE SISTEMAS Y AUTOMATICA es_ES
dc.title Turmell-Meter: A Device for Estimating the Subtalar and Talocrural Axes of the Human Ankle Joint by Applying the Product of Exponentials Formula es_ES
dc.type Artículo es_ES
dc.identifier.doi 10.3390/bioengineering9050199 es_ES
dc.relation.projectID info:eu-repo/grantAgreement/UPV-VIN//AYUDA PAID-11-21//Parallel rehabilitation robots: detection and control of singularities in the presence of manufacturing errors/ es_ES
dc.relation.projectID info:eu-repo/grantAgreement/COLCIENCIAS//568/ es_ES
dc.rights.accessRights Abierto es_ES
dc.contributor.affiliation Universitat Politècnica de València. Escola Tècnica Superior d'Enginyeria Informàtica es_ES
dc.description.bibliographicCitation Agudelo-Varela, Ó.; Vargas-Riaño, J.; Valera Fernández, Á. (2022). Turmell-Meter: A Device for Estimating the Subtalar and Talocrural Axes of the Human Ankle Joint by Applying the Product of Exponentials Formula. Bioengineering. 9(5):1-35. https://doi.org/10.3390/bioengineering9050199 es_ES
dc.description.accrualMethod S es_ES
dc.relation.publisherversion https://doi.org/10.3390/bioengineering9050199 es_ES
dc.description.upvformatpinicio 1 es_ES
dc.description.upvformatpfin 35 es_ES
dc.type.version info:eu-repo/semantics/publishedVersion es_ES
dc.description.volume 9 es_ES
dc.description.issue 5 es_ES
dc.identifier.eissn 2306-5354 es_ES
dc.identifier.pmid 35621477 es_ES
dc.identifier.pmcid PMC9137974 es_ES
dc.relation.pasarela S\464851 es_ES
dc.contributor.funder UNIVERSIDAD POLITECNICA DE VALENCIA es_ES
dc.contributor.funder Departamento Administrativo de Ciencia, Tecnología e Innovación, Colombia es_ES
upv.costeAPC 1669,34 es_ES


Este ítem aparece en la(s) siguiente(s) colección(ones)

Mostrar el registro sencillo del ítem