- -

Scanning accuracy of nondental structured light extraoral scanners compared with that of a dental-specific scanner.

RiuNet: Repositorio Institucional de la Universidad Politécnica de Valencia

Compartir/Enviar a

Citas

Estadísticas

  • Estadisticas de Uso

Scanning accuracy of nondental structured light extraoral scanners compared with that of a dental-specific scanner.

Mostrar el registro sencillo del ítem

Ficheros en el ítem

dc.contributor.author Piedra-Cascón, Wenceslao es_ES
dc.contributor.author Methani, Mohamed M. es_ES
dc.contributor.author Quesada-Olmo, María Nieves es_ES
dc.contributor.author Jiménez-Martínez, Mª Jesús es_ES
dc.contributor.author Revilla-León, Marta es_ES
dc.date.accessioned 2023-11-22T19:02:37Z
dc.date.available 2023-11-22T19:02:37Z
dc.date.issued 2021-07 es_ES
dc.identifier.issn 0022-3913 es_ES
dc.identifier.uri http://hdl.handle.net/10251/200130
dc.description.abstract [EN] Statement of problem. Diagnostic stone casts can be digitized by using dental optical scanners based on structured light scanning technology. Nondental structured light scanning scanners could also be used; however, the accuracy of these nondental scanners remains unclear. Purpose. The purpose of this in vitro study was to measure the scanning accuracy (trueness and precision) of 3 nondental extraoral structured light scanners. Material and methods. A representative maxillary diagnostic cast was obtained and digitized by using an extraoral dental scanner (Advaa Lab Scan; GC Europe), and a reference or control standard tessellation language file was obtained. Three nondental extraoral scanners were evaluated: groups ND-1 (Space Spider; Artec), ND-2 (Capture Mini; Geomagic), and ND-3 (DAVID SLS3; David). Ten digital scans per group were recorded at a constant room temperature (23 degrees C) by an experienced geodetic engineer following the manufacturer's recommendations. The control or reference file was used as a reference to measure the discrepancy between the digitized diagnostic cast and 3 different nondental scans by using an open-source software (CloudCompare v.2.6.1; CloudCompare) and the iterative closest point technique. The Shapiro-Wilk test revealed that the data were normally distributed. The data were analyzed by using 1-way ANOVA, followed by post hoc Bonferroni tests (alpha=.05). Results. Significant differences between the 3 experimental nondental scanners and the control or reference scan (P<.001) were found. The ND-2 group had the lowest absolute mean error (trueness) and standard deviation (precision) (39 +/- 139 mu m), followed by the ND-3 group (125 +/- 113 mu m) and the ND1 group (-397 +/- 25 mu m). No statistically significant differences were found in the mean error between the ND-2 and ND-3 groups (P=.228). Conclusions. Only 1 nondental extraoral scanner tested obtained trueness mean values similar to those of the reference dental scanner. In all groups, the precision mean values were higher than their trueness values, indicating low relative precision. es_ES
dc.language Inglés es_ES
dc.publisher Elsevier - Mosby es_ES
dc.relation.ispartof Journal of Prosthetic Dentistry es_ES
dc.rights Reserva de todos los derechos es_ES
dc.subject.classification INGENIERIA CARTOGRAFICA, GEODESIA Y FOTOGRAMETRIA es_ES
dc.title Scanning accuracy of nondental structured light extraoral scanners compared with that of a dental-specific scanner. es_ES
dc.type Artículo es_ES
dc.identifier.doi 10.1016/j.prosdent.2020.04.009 es_ES
dc.rights.accessRights Cerrado es_ES
dc.contributor.affiliation Universitat Politècnica de València. Escuela Técnica Superior de Ingeniería Geodésica, Cartográfica y Topográfica - Escola Tècnica Superior d'Enginyeria Geodèsica, Cartogràfica i Topogràfica es_ES
dc.description.bibliographicCitation Piedra-Cascón, W.; Methani, MM.; Quesada-Olmo, MN.; Jiménez-Martínez, MJ.; Revilla-León, M. (2021). Scanning accuracy of nondental structured light extraoral scanners compared with that of a dental-specific scanner. Journal of Prosthetic Dentistry. 126(1):110-114. https://doi.org/10.1016/j.prosdent.2020.04.009 es_ES
dc.description.accrualMethod S es_ES
dc.relation.publisherversion https://doi.org/10.1016/j.prosdent.2020.04.009 es_ES
dc.description.upvformatpinicio 110 es_ES
dc.description.upvformatpfin 114 es_ES
dc.type.version info:eu-repo/semantics/publishedVersion es_ES
dc.description.volume 126 es_ES
dc.description.issue 1 es_ES
dc.identifier.pmid 32665118 es_ES
dc.relation.pasarela S\416117 es_ES


Este ítem aparece en la(s) siguiente(s) colección(ones)

Mostrar el registro sencillo del ítem