- -

Estimation of energy expenditure in adults with accelerometry and heart rate

RiuNet: Repositorio Institucional de la Universidad Politécnica de Valencia

Compartir/Enviar a

Citas

Estadísticas

  • Estadisticas de Uso

Estimation of energy expenditure in adults with accelerometry and heart rate

Mostrar el registro sencillo del ítem

Ficheros en el ítem

dc.contributor.author Bazuelo-Ruiz, B. es_ES
dc.contributor.author De Rosario Martínez, Helios es_ES
dc.contributor.author DURÁ-GIL, JUAN V. es_ES
dc.date.accessioned 2023-12-01T19:00:40Z
dc.date.available 2023-12-01T19:00:40Z
dc.date.issued 2022-10 es_ES
dc.identifier.issn 0765-1597 es_ES
dc.identifier.uri http://hdl.handle.net/10251/200417
dc.description.abstract [Otros] Objectifs. - Une détermination précise de la dépense énergétique (EE) par accélérométrie est importante pour l¿efficacité des programmes d¿AP. L¿écart d¿amplitude moyen (MAD) est un bon paramètre pour distinguer l¿intensité de l¿activité physique. Ici, les objectifs de la présente étude étaient doubles: a) développer une nouvelle équation d¿estimation de l¿EE utilisant les données brutes de l¿accéléromètre et la fréquence cardiaque, et b) comparer la consommation d¿oxygène mesurée avec la nouvelle équation développée et les équations de prédiction les plus utilisées la littérature chez les adultes de poids normal et en surpoids. Matériel et méthodes. - Vingt adultes en bonne santé (10 hommes et 10 femmes) portaient un appareil portable sur la poitrine qui intègre des signaux d¿accélérométrie triaxiale et d¿ECG. Le protocole de test consistait en 12 intensités individualisées, 6 vitesses de marche et 6 vitesses de course également réparties. La corrélation entre la MAD et la consommation d¿oxygène mesurée a été étudiée. Ensuite, une nouvelle équation d¿estimation de la dépense énergétique a été développée et comparée à cinq formules de la littérature. Résultats. - Nos résultats ont noté que MAD avait une très forte corrélation (r = 0,937) avec la calorimétrie indirecte. La nouvelle équation développée avait l¿une des deux erreurs absolues moyennes les plus faibles pour la marche et la course. Par conséquent, notre équation semble convenir à la fois à la marche et à la course, aux personnes de poids normal et en surpoids. Cependant, les études futures devraient valider notre nouvelle équation d¿estimation de l¿EE avec un large éventail de conditions de population et de terrain. es_ES
dc.description.abstract [EN] Objectives. - Accurate determination of energy expenditure (EE) through accelerometry is relevant in the effectiveness of the PA programs. The mean amplitude deviation (MAD) is a good parameter to distinguish the intensity of physical activity. Here, the aims of the present study were twofold: a) to develop a new EE estimation equation using raw accelerometer data and heart rate, and b) to compare the oxygen consumption measured with the new equation developed and the most commonly used prediction equations in the literature in normal weight and overweight adults. Equipment and methods. - Twenty healthy adults (10 males and 10 females) wore a wearable device on the chest that integrates triaxial accelerometry and ECG signals. The test protocol consisted in 12 individualized intensities, 6 walking and 6 running speeds equally distributed. The correlation between MAD and measured oxygen consumption was investigated. Then, a new energy expenditure estimation equation was developed and compared with five formulas from the literature. Results. - Our results noted that MAD had a very high correlation (r = 0.937) with indirect calorimetry. The new equation developed had one of the two lowest mean absolute errors for both walking and running. Therefore, our equation appears to be suitable for both walking and running, for normal weight and overweight people. However, future studies should validate our new EE estimation equation with a wide range of population and field-based conditions. es_ES
dc.description.sponsorship This work was supported by the Seventh European Framework Programme (FP7.FoF.NMP.2013-5) under grantagreement 609078 (EASY-IMP). The funders had no role instudy design, data collection and analysis, decision to publish, or preparation of the manuscript. es_ES
dc.language Inglés es_ES
dc.publisher Elsevier es_ES
dc.relation.ispartof Science & Sports es_ES
dc.rights Reconocimiento - No comercial - Sin obra derivada (by-nc-nd) es_ES
dc.subject Oxygen consumption es_ES
dc.subject Lifestyle es_ES
dc.subject ECG signals es_ES
dc.subject Wearable device es_ES
dc.subject Consommation d¿oxygène es_ES
dc.subject Mode de vie es_ES
dc.subject Signaux ECG es_ES
dc.subject Dispositif portable es_ES
dc.title Estimation of energy expenditure in adults with accelerometry and heart rate es_ES
dc.title.alternative Estimation de la dépense énergétique chez l¿adulte par l¿accélérométrie et fréquence cardiaque es_ES
dc.type Artículo es_ES
dc.identifier.doi 10.1016/j.scispo.2021.08.007 es_ES
dc.relation.projectID info:eu-repo/grantAgreement/EC/FP7/609078/EU es_ES
dc.relation.projectID info:eu-repo/grantAgreement/EC//FP7.FoF.NMP.2013-5/ es_ES
dc.rights.accessRights Abierto es_ES
dc.contributor.affiliation Universitat Politècnica de València. Instituto Universitario Mixto de Biomecánica de Valencia - Institut Universitari Mixt de Biomecànica de València es_ES
dc.description.bibliographicCitation Bazuelo-Ruiz, B.; De Rosario Martínez, H.; Durá-Gil, JV. (2022). Estimation of energy expenditure in adults with accelerometry and heart rate. Science & Sports. 37(5-6):431-437. https://doi.org/10.1016/j.scispo.2021.08.007 es_ES
dc.description.accrualMethod S es_ES
dc.relation.publisherversion https://doi.org/10.1016/j.scispo.2021.08.007 es_ES
dc.description.upvformatpinicio 431 es_ES
dc.description.upvformatpfin 437 es_ES
dc.type.version info:eu-repo/semantics/publishedVersion es_ES
dc.description.volume 37 es_ES
dc.description.issue 5-6 es_ES
dc.relation.pasarela S\489298 es_ES
dc.contributor.funder European Commission es_ES


Este ítem aparece en la(s) siguiente(s) colección(ones)

Mostrar el registro sencillo del ítem