- -

Reliability of My Jump 2 Derived from Crouching and Standing Observation Heights

RiuNet: Repositorio Institucional de la Universidad Politécnica de Valencia

Compartir/Enviar a

Citas

Estadísticas

  • Estadisticas de Uso

Reliability of My Jump 2 Derived from Crouching and Standing Observation Heights

Mostrar el registro sencillo del ítem

Ficheros en el ítem

dc.contributor.author Jimenez-Olmedo, Jose M. es_ES
dc.contributor.author Pueo, Basilio es_ES
dc.contributor.author Mossi García, José Manuel es_ES
dc.contributor.author Villalon-Gasch, Lamberto es_ES
dc.date.accessioned 2023-12-13T19:00:36Z
dc.date.available 2023-12-13T19:00:36Z
dc.date.issued 2022-08 es_ES
dc.identifier.issn 1661-7827 es_ES
dc.identifier.uri http://hdl.handle.net/10251/200730
dc.description.abstract [EN] The crouching or prone-on-the-ground observation heights suggested by the My Jump app are not practical in some settings, so users usually hold smartphones in a standing posture. This study aimed to analyze the reliability of My Jump 2 from the standardized and standing positions. Two identical smartphones recorded 195 countermovement jump executions from 39 active adult athletes at heights 30 and 90 cm, which were randomly assessed by three experienced observers. The between-observer reliability was high for both observation heights separately (ICC similar to 0.99; SEM similar to 0.6 cm; CV similar to 1.3%) with low systematic (0.1 cm) and random (+/- 1.7 cm) errors. The within-observer reliability for the three observers comparing the standardized and standing positions was high (ICC similar to 0.99; SEM similar to 0.7 cm; CV similar to 1.4%), showing errors of 0.3 +/- 1.9 cm. Observer 2 was the least accurate out of the three, although reliability remained similar to the levels of agreement found in the literature. The reliability of the mean observations in each height also revealed high reliability (ICC = 0.993; SEM = 0.51 cm; CV = 1.05%, error 0.32 +/- 1.4 cm). Therefore, the reliability in the standing position did not change with respect to the standardized position, so it can be regarded as an alternative method to using My Jump 2 with practical added benefits. es_ES
dc.description.sponsorship This research was funded by Generalitat Valenciana, grant number GV/2021/098. es_ES
dc.language Inglés es_ES
dc.publisher MDPI AG es_ES
dc.relation.ispartof International Journal of Environmental research and Public Health es_ES
dc.rights Reconocimiento (by) es_ES
dc.subject Smartphone es_ES
dc.subject Jump es_ES
dc.subject Error es_ES
dc.subject Test es_ES
dc.subject Within-observer es_ES
dc.subject Between-observer es_ES
dc.subject Measurement es_ES
dc.subject.classification TEORÍA DE LA SEÑAL Y COMUNICACIONES es_ES
dc.title Reliability of My Jump 2 Derived from Crouching and Standing Observation Heights es_ES
dc.type Artículo es_ES
dc.identifier.doi 10.3390/ijerph19169854 es_ES
dc.relation.projectID info:eu-repo/grantAgreement/GVA//GV%2F2021%2F098/ es_ES
dc.rights.accessRights Abierto es_ES
dc.contributor.affiliation Universitat Politècnica de València. Escuela Técnica Superior de Ingenieros de Telecomunicación - Escola Tècnica Superior d'Enginyers de Telecomunicació es_ES
dc.description.bibliographicCitation Jimenez-Olmedo, JM.; Pueo, B.; Mossi García, JM.; Villalon-Gasch, L. (2022). Reliability of My Jump 2 Derived from Crouching and Standing Observation Heights. International Journal of Environmental research and Public Health. 19(16):1-12. https://doi.org/10.3390/ijerph19169854 es_ES
dc.description.accrualMethod S es_ES
dc.relation.publisherversion https://doi.org/10.3390/ijerph19169854 es_ES
dc.description.upvformatpinicio 1 es_ES
dc.description.upvformatpfin 12 es_ES
dc.type.version info:eu-repo/semantics/publishedVersion es_ES
dc.description.volume 19 es_ES
dc.description.issue 16 es_ES
dc.identifier.pmid 36011491 es_ES
dc.identifier.pmcid PMC9408288 es_ES
dc.relation.pasarela S\481156 es_ES
dc.contributor.funder Generalitat Valenciana es_ES


Este ítem aparece en la(s) siguiente(s) colección(ones)

Mostrar el registro sencillo del ítem