dc.description.abstract | [EN] This paper reports on the energy consumption study of a typical Valencian house with the aim of achieving a maximum reduction in HVAC energy demand. With this purpose, an extensive simulation project was done by using TRNsys 17 software. Previously, all necessary data were collected and studied. Then, an energy simulation of the original house was performed, hence obtaining experimental evidence to verify the predictive capability of the developed energy model. Subsequently, the energy optimization strategy was proposed and the measures to improve the energy demand were implemented on the model, in order to reach a zero HVAC demand. Finally, the following conclusions were obtained: energy model adjustment is fundamental for reproducing the specific thermal behavior of the studied building and for the optimization of the energy demand and secondly, enhancing the building envelope is the most effective proposal for achieving the reduction in the HVAC requirements for the building. | es_ES |
dc.description.abstract | [ES] El documento describe el estudio energético desarrollado con el objetivo de lograr una máxima reducción de la demanda de energía para finalmente obtener un cero consumo de climatización. Con este objetivo se ha llevado a cabo un trabajo muy extenso de simulación con el uso del software TRNsys 17 con los siguientes pasos consecutivos: Registro previo de todos los datos climáticos y constructivos registran del edificio original es llevado a cabo, obteniendo de esa manera la comparación experimental para comprobar la capacidad predictiva del modelo energético desarrollado. La estrategia de optimización energética se planea cuidadosamente y las propuestas de mejora se aplican en el modelo con el análisis detallado de los resultados. Se obtienen las siguientes conclusiones: En el ajuste del modelo energético es fundamental reproducir el comportamiento térmico específico del edificio estudiado En la optimización de la demanda de energía, el aislamiento de la envolvente del edificio es la propuesta más eficaz para lograr la reducción de los requerimientos energéticos del edificio. | es_ES |
dc.language | Inglés | es_ES |
dc.publisher | CRC Press | es_ES |
dc.relation.ispartof | Vernacular and Earthen Architecture. Conservation and Sustainability | es_ES |
dc.rights | Reserva de todos los derechos | es_ES |
dc.subject | Energy optimization | es_ES |
dc.subject | Building simulation | es_ES |
dc.subject | TRNSYS | es_ES |
dc.subject.classification | CONSTRUCCIONES ARQUITECTONICAS | es_ES |
dc.subject.classification | MAQUINAS Y MOTORES TERMICOS | es_ES |
dc.title | Consumption study and energy optimization of a typical Valencian house | es_ES |
dc.type | Comunicación en congreso | es_ES |
dc.type | Capítulo de libro | es_ES |
dc.rights.accessRights | Abierto | es_ES |
dc.contributor.affiliation | Universitat Politècnica de València. Escuela Técnica Superior de Arquitectura - Escola Tècnica Superior d'Arquitectura | es_ES |
dc.contributor.affiliation | Universitat Politècnica de València. Escuela Técnica Superior de Ingenieros Industriales - Escola Tècnica Superior d'Enginyers Industrials | es_ES |
dc.description.bibliographicCitation | Martínez-Ibernón, A.; Royo, R.; Tormo Esteve, S. (2018). Consumption study and energy optimization of a typical Valencian house. CRC Press. 295-300. http://hdl.handle.net/10251/201361 | es_ES |
dc.description.accrualMethod | S | es_ES |
dc.relation.conferencename | International Conference on Vernacular Earthen Architecture, Conservation and Sustainability (SOStierra 2017, 3rd VerSus, 3rd ResTAPIA) | es_ES |
dc.relation.conferencedate | Septiembre 14-16,2017 | es_ES |
dc.relation.conferenceplace | Valencia, Spain | es_ES |
dc.description.upvformatpinicio | 295 | es_ES |
dc.description.upvformatpfin | 300 | es_ES |