dc.contributor.author | Catalá-Icardo, Mónica | es_ES |
dc.contributor.author | Giménez-Romero, D. | es_ES |
dc.contributor.author | García Mateo, J.V. | es_ES |
dc.contributor.author | Martínez Calatayud, J. | es_ES |
dc.date.accessioned | 2024-01-11T19:02:38Z | |
dc.date.available | 2024-01-11T19:02:38Z | |
dc.date.issued | 2000-02-29 | es_ES |
dc.identifier.issn | 0003-2670 | es_ES |
dc.identifier.uri | http://hdl.handle.net/10251/201827 | |
dc.description.abstract | [EN] A flow injection assembly for the determination of chloramine-T is proposed. The sample (213 mu l) is inserted into the carrier, de-ionized water flowing at 4.1 mi min(-1). This carrier merges with a mixture of potassium iodide and sulphuric acid, and the resulting solution flows to the flow cell through a reactor 66 cm long. The chloramine-T oxidises the iodide to tri-iodide. The resulting iodide/iodine ratio is biamperometrically tested. The calibration graph is linear up to 65 mu g ml(-1) chloramine-T; the limit of detection is 0.5 mu g ml(-1); the relative standard deviation (r.s.d) of the calibration slope is 2.8% for a series of eight independent calibrations. The r.s.d. of a series of 74 peaks for 40 mu g ml(-1) chloramine-T) is 0.8%, and the sample throughput 220 h(-1). Few foreign substances interfered. The method is applied to pharmaceutical, veterinary and waste water samples. | es_ES |
dc.language | Inglés | es_ES |
dc.publisher | Elsevier | es_ES |
dc.relation.ispartof | Analytica Chimica Acta | es_ES |
dc.rights | Reconocimiento - No comercial - Sin obra derivada (by-nc-nd) | es_ES |
dc.subject | Chloramine-T | es_ES |
dc.subject | Flow injection analysis (FIA) | es_ES |
dc.subject | Pharmaceutical analysis | es_ES |
dc.subject | Clinical analysis | es_ES |
dc.subject | Waste water analysis | es_ES |
dc.subject | Biamperometry | es_ES |
dc.subject.classification | QUIMICA ANALITICA | es_ES |
dc.title | Flow injection biamperometric determination of chloramine-T in environmental, pharmaceutical and veterinary samples | es_ES |
dc.type | Artículo | es_ES |
dc.identifier.doi | 10.1016/S0003-2670(99)00791-6 | es_ES |
dc.rights.accessRights | Abierto | es_ES |
dc.contributor.affiliation | Universitat Politècnica de València. Escuela Politécnica Superior de Gandia - Escola Politècnica Superior de Gandia | es_ES |
dc.description.bibliographicCitation | Catalá-Icardo, M.; Giménez-Romero, D.; García Mateo, J.; Martínez Calatayud, J. (2000). Flow injection biamperometric determination of chloramine-T in environmental, pharmaceutical and veterinary samples. Analytica Chimica Acta. 407(1-2):187-192. https://doi.org/10.1016/S0003-2670(99)00791-6 | es_ES |
dc.description.accrualMethod | S | es_ES |
dc.relation.publisherversion | https://doi.org/10.1016/S0003-2670(99)00791-6 | es_ES |
dc.description.upvformatpinicio | 187 | es_ES |
dc.description.upvformatpfin | 192 | es_ES |
dc.type.version | info:eu-repo/semantics/publishedVersion | es_ES |
dc.description.volume | 407 | es_ES |
dc.description.issue | 1-2 | es_ES |
dc.relation.pasarela | S\25845 | es_ES |